|
Anleitung Zusammenfassung
Replace glass only with 5mm ceramic available from your dealer. Do not use grate or elevate fire. Build wood fire directly on hearth. Do not overfire -if heater or chimney connector glows, you are overfiring. Operate only with the fuel loading door closed. Open only to add fuel to the fire. CAUTION: U.S. ENVIRONMENTAL PROTECTION AGENCY - Certified to comply with July 1990 particulate emission standards. 2008 2009 2010 Jan. Feb. Mar. Apr. May June July Aug. Sept. Oct. Nov. Dec. PREVENT HOUSE FIRES FLOOR PROTECTION: Floor protector must be a 3/8 inch min. thickness, non-combustible material or equivalent, extending beneath heater and to front/sides/rear as indicated on the diagram below. Exception: Non-combustible floor protections must extend beneath the flue pipe when installed with horizontal venting and extend 2 inches (51mm) beyond each side. Report / Rapport #061-S-31b-2 TESTED TO:/ TESTE A: UL 1482, ULC S627-00 Manufactured by: HOT WHILE IN OPERATION DO NOT TOUCH, KEEP CHILDREN AND CLOTHING AWAY. CONTACT MAY CAUSE SKIN BURNS. KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIAL FAR AWAY FROM THE APPLIANCE. SEE NAMEPLATE AND INSTRUCTIONS A B C D E F G H SINGLE WALL PIPE 15.25 (387) 11.75 (298) 25.5 (648) 16 (406) 8 (203) 17 (432) 48 (1220) 12(305) DOUBLE WALL PIPE 10.5 (267) 6.5 (165) 22 (559) 13 (330) 6.5 (165) 15.5 (394) 48 (1220) 9 (229) SINGLE WALL PIPE 12 (305) 8.5 (216) 22 (559) 13 (330) 8 (203) 17 (432) 48 (1220) 12 (305) DOUBLE WALL PIPE 8 (203) 4.5 (114) 17.5 (445) 8.5 (216) 6.5 (165) 15.5 (394) 48 (1220) 9 (229) INSTALLATION: ALCOVE -Six inch (6") (152mm) diameter listed DOUBLE WALL air insulated connector pipe with UL 103HT listed factory-built Class "A" chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor.) Maximum depth of Alcove shall be no more than 48 inches (1220mm) with a minimum height of 48 inches (1220mm) to top of unit, and the referenced clearances. DOUBLE WALL PIPE 11.75 (298) 8.25 (210) 23.5 (597) 14.5 (368) N/A N/A 48 (1220) * * SEE PIPE MANUFACTURERS CLEARANCES - NOT TESTED / VOIR LE FABRICANT POUR LES ESPACES LIBRES DES CONDUIT - PAS TESTE VENT SPECIFICATIONS: SINGLE WALL: Six inch (6") (152mm) diameter, minimum 24 MSG black or blued steel connector pipe, with a listed factory-built UL103HT* Class "A" chimney, suitable for use with solid fuels, or a masonry chimney, and the referenced clearances. DOUBLE WALL: Six inch (6") (152mm) diameter, listed double wall air insulated connector pipe with listed factory-built UL103HT* Class "A" chimney, or a masonry chimney and the referenced clearances *In Canada must comply with Standard CAN/ULC-S629-M87 for the 650 degree Factory-built chimneys. MOBILE HOME: Use double wall pipe by Dura-Vent DVL, Selkirk Metalbestos DS or Security DL double wall connector pipe. Must be equipped with a spark arrestor. Apply double wall clearances below when installing unit. SERIAL NO. / NUMERO DE SERIE A B C D E FE F G H G A B C D R 16" from glass 8" USA Fuel loading door 4-7/8" 3-1/8" 31-5/8" 39-5/8” 7033-124 CANADA 203mm (8") 203mm (8") 203mm (8") 457mm (18") 1260mm (49-5/8") minimum 1040mm (41") minimum CHAUD LORS DE L'OPERATION. NE PAS TOUCHER. GARDEZ LES ENFANTS ET LES VETEMENTS LOIN DE L'ESPACE DESIGNE DE L'INSTALLATION. LE CONTACT PEUT CAUSER DES BRULURES A LA PEAU. GARDEZ LES MEUBLES ET LES MATERIAUX COMBUSTIBLES LOIN DE L'ESPACE DESIGNE DE L'APPAREIL. VOIR L'ETIQUETTE ET LES INSTRUCTIONS. ATTENTION: APPAREIL DE CHAUFFAGE DE PIECE, DE TYPE DE COMBUSTIBLE SOLIDE, POUR USAGE DANS LES MAISONS MOBILES. (UM) 84-64 HUD. "Pour Usage Avec Bois Solide Seulement" Installez et utilisez en accord avec les instructions d'installation et d'operation du fabricant. Contactez le bureau de la construction ou le bureau des incendies au sujet des restrictions et des inspections d'installation dans votre voisinage. Ne pas obstruez l'espace en dessous de l'appareil. AVIS -Pour Les Maisons Mobiles: Ne pas installer dans une chambre a coucher. Un tuyau exterieur de combustion d'air doit etre installe et ne doit pas etre obstrue lorsque l'appareil est en usage. La structure integrale du plancher, du plafond et des murs de la maison mobile doit etre maintenue intacte. L'appareil de chauffage doit etre fixe a la charpente de la maison mobile. Les composants requis pour l'installation des maisons mobiles: Assemblage d'air exterieur, Numero de Piece OAK-ACC. Referez vous aux instructions du fabricant et des codes locaux pour les precautions requises pour passer une cheminee a travers un mur ou un plafond combustibles, et les compensations maximums. Inspectez et nettoyez la cheminee frequemment. Sous certaines conditions, il se peut que la creosote s'accumule rapidement. Ne pas connecter cet appareil a une cheminee servant un autre appareil. Composants Optionnels: Ventilateur Optionnel, Piece BK-ACC. Puissance Electrique: 115 VAC, 1.2 Amps, 60 Hz. Eloignez le fil electrique de l'appareil. Ne pas faire passer le fil electrique au dessus ou en dessous ...
Dieses Handbuch ist für folgende Modelle:Standbacköfen - 31ST-ACC (2.94 mb)