Login:
Stimmen - 2, Durchschnittliche Bewertung: 3.5 ( )

Anleitung Hearth and Home Technologies, modell Quadra-Fire 43M-ACC-MBK

Hersteller: Hearth and Home Technologies
Dateigröße: 2.97 mb
Dateiname: 4962cf70-bc3b-435d-980a-5c1c94abd11c.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Installation and Operation Models: 43M-ACC-MBK 43ST-ACC Millennium Model CAUTION DO NOT DISCARD THIS MANUAL • Important operating and maintenance instructions included. • Leave this manual with party responsible for use and operation. • Read, understand and follow these instructions for safe installation and operation. DO NOTDISCARD WARNING If the information in these instruc tions is not followed exactly, a fire may result causing property damage, personal injury, or death. • Do not store or use gasoline or other flammable vapors and liquids in the vicinity ofthis or any other appliance. • Do not overfire - If heater or chimney connector glows, you are overfiring. Overfiring will void your warranty. • Comply with all minimum clearances tocombustibles as specified. Failure to comply may cause house fire. WARNING Hot glass will cause burns. • Do not touch glass until it is cooled • NEVER allow children to touch glass • Keep children away • CAREFULLY SUPERVISE children in same room as fireplace. • Alert children and adults to hazards of high temperatures. High temperatures may ignite clothing or other flammable materials. • Keep clothing, furniture, draperies and other flammable materials away. HOT SURFACES! Glass and other surfaces are hot during operation AND cool down. Fire Risk. WARNING For use with solid wood fuel only. Other fuels may overfire and generate poisonous gases (i.e. carbon monoxide). Installation and service of this appliance should be performed by qualified personnel. Hearth & Home Technologies recommends NFI certified professionals, or technicians supervised by an NFI certified professional. 7037-135E September 1, 2008 4300 Wood Stove Series (ACC) R and Welcome to the Quadra-Fire Family! Hearth & Home Technologies welcomes you to our tradition of excellence! In choosing a Quadra-Fire appliance, you have our assurance of commitment to quality, durability, and performance. This commitment begins with our research of the market, including ‘Voice of the Customer’ contacts, ensuring we make products that will satisfy your needs. Our Research and Development facility then employs the world’s most advanced technology to achieve the optimum operation of our stoves, inserts and fireplaces. And yet we are old-fashioned when it comes to craftsmanship. Each unit is meticulously fabricated and surfaces are hand-finished for lasting beauty and enjoyment. Our pledge to quality is completed as each model undergoes a quality control inspection. We wish you and your family many years of enjoyment in the warmth and comfort of your hearth appliance. Thank you for choosing Quadra-Fire. SAMPLE OF SERIAL NUMBER / SAFETY LABEL LOCATION: BACK OF APPLIANCE INSTALLATION: FULL VERTICAL OR HORIZONTAL WITH MINIMUM 2 FOOT VERTICAL OFF STOVE TOP INSTALLATION: ENTIEREMENT VERTICALE OU HORIZONTALE AVEC 609mm VERTICAL MINIMUM DU HAUT DU POELE SINGLE WALL PIPE A B C D E F G H Flat Top Model 18 (457) 15.5 (394) 26 (660) 17 (432) 10 (255) 18.5 (470) 52.5 (1334) 18 (457)* Step Top Model 12 (305) 8.5 (216) 23 (584) 13 (330) 2 (51) 13 (330) 50.5 (1283) 18 (457)* DOUBLE WALL PIPE Flat Top Model 13 (330) 10.5 (267) 24.5 (622) 15 (381) 10 (255) 18.5 (470) 52.5 (1334) 10 (254) Step Top Model 10 (254) 6.5 (165) 23 (584) 13 (330) 2 (51) 13 (330) 50.5 (1283) 5 (127) INSTALLATION: 90o ELBOW OFF TOP OF STOVE THROUGH BACKWALL INSTALLATION: 90o DU COURBURE AU DESSUS DE HAUT DU POELE A TRAVERS LE MUR ARRIERE DOUBLE WALL PIPE Flat Top Model 8.5 (216) 6 (152) 24.5 (622) 15 (381) 10 (254) 18.5 (470) 52.5 (1334) 18 (457)* Step Top Model 7.5 (191) 4 (102) 19 (483) 9 (229) 2 (51) 13 (330) 50.5 (1283) 18 (457)* INSTALLATION: ALCOVE -Six inch (6 inches) (152mm) diameter listed DOUBLE WALL air insulated connector pipe with UL103 HT* listed factory-built Class "A" chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor.) Maximum depth of Alcove shall be no more than 48 inches (1220mm) with a minimum height of 45.5 inches (1156mm) to top of unit, and the referenced clearances. Please refer to the clearances below for minimum Alcove height requirement to top of unit. INSTALLATION: ALCOVE -De six (6 inches) (152mm) de diametre, le connecteur du conduit d'air isole pour mur double avec une cheminee batit en usine UL103HT de Classe "A", ou une cheminee de briques. (Les maisons mobiles doivent etre equipees d'un arret d'etincelle). La profondeur maximum de l'alcove ne doit pas etre de plus de 48 inches (1220mm) avec une hauteur minimum de 45.5 inches (1156mm) du haut de l'appareil, et des espaces libres alloues. Referez vous s'il vous plait aux degagements repirs ci-dessus pour la hauteru minimum requise entre le dessus ole l'appareil et l'alcove (de la chiminee). DOUBLE WALL PIPE Flat Top Model 13 (330) 10.5 (267) 24.5 (622) 15 (381) N/A N/A 52.5 (1334) N/AStep Top Model 10 (254) 6.5 (165) 23 (584) 13 (330) N/A N/A 37 (940) N/A *In Canada must comply with Standard CAN/ULC-S629-M87 for the 650oC Factory-built ch...

Dieses Handbuch ist für folgende Modelle:
Standbacköfen - Quadra-Fire 43ST-ACC (2.97 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien