Login:
Stimmen - 1, Durchschnittliche Bewertung: 5 ( )

Anleitung Blodgett, modell Precision Series

Hersteller: Blodgett
Dateigröße: 3.36 mb
Dateiname: eba66508-fe11-4cef-9af8-4d8dacdc5e1d.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


7.Models with open char broiler, noncombustible material is to be installed on the underside of a cabinet located above the broiler section or unit in accordance with local codes, or in the absence of local codes, with the National Fuel Gas code, ANSI Z223.1/NFPA 54. WARNING: DO NOT obstruct the flow of combustion and ventilation air to the unit. PLEASE NOTE: In the Commonwealth of Massachusetts, gas connection must be performed by a licensed plumber or licensed gas fitter. 32 C A B I N E T I N S T A L L D R AW I N G / F R O N T V I E W FIG 1A. Cabinet Clearances: CABINET INSTALL DRAWING / SIDE VIEW FIG 2A Side View: 34 WALL MOUNT BACKGUARD INSTALLATION NOTE: ALL PRECISION SERIES RANGES come with an island trim. • Secure the back guard (19” High Shelf, or 9” Low Back) directly on the wall behind range and above the factory installed island trim. DO NOT REMOVE the island trim. It is necessary for proper venting of the oven gases/heat. BACKGUARD MOUNTING: WALL MOUNT HIGH SHELF 1. First measure from top of island trim to 16 3/8” to what will be the center of the mounting brackets. (see Fig 1) 2. Secure both brackets to the wall using the screws included. 3. Attach the shelf to the shelf support panels with supplied screws. 4. Slide shelf into position and over brackets. BACKGUARD MOUNTING: WALL MOUNT LOW BACK 1. First measure from top of island trim to 16 3/8” to what will be the center of the mounting brackets. (see Fig 1) 2. Secure both brackets to the wall using the screws included. 3. Slide shelf into position and over brackets. ELECTRICAL SUPPLY, ALL RANGES Installation of All Precision ranges must be planned so that the rough-in of the junction box for the receptacle or conduit connection allows for maximum clearance to the rear of the unit. This is especially critical if the junction box in the wall will be directly behind the junction box of the unit when the unit is installed. To minimize binding when the unit is connected to the receptacle or junction box, orient the receptacle or conduit connector, and slide back into position. POWER REQUIREMENTS: 120 VAC, 60 HZ single phase • 24” Range – 4 Amps. Max. • 30” Range – 7 Amps. Max. • 36” Range – 7 Amps. Max. • 48” Range – 13 Amps. Max. • 60” Range – 13 Amps. Max CAUTION! Disconnect the electrical supply cord from the wall outlet before servicing the range. Follow all governing codes and ordinances when grounding. In the absence of codes follow the National Electrical Codes ANSI / NFPA No. 70 (current issue). GROUNDING METHOD The range is factory fitted with a power supply and cord with a three-prong grounding plug. It must be plugged into a matching grounding type receptacle connected to a correctly polarized 120 Volt circuit. If the circuit does not have a grounding type receptacle, it is the responsibility of the installer to have the existing receptacle changed to a properly grounded and polarized receptacle in accordance with all applicable local codes and ordinances. The receptacle replacement shall be in accordance with the national Electrical Code. WARNING! The third prong SHOULD NOT, under any circumstances, be cut or removed! I N S T A L L A T I O N I N S T R U C T I O N S INSTALLATION INSTRUCTIONS WARNING! • ALL RANGES CAN TIP • INJURY TO PERSONS COULD RESULT • INSTALL ANTI-TIP DEVICES PACKED WITH RANGE • SEE INSTALLATION INSTRUCTION WARNING: RANGE TIPPING HAZARD! • All ranges can tip and injury can result. To prevent accidental tipping of the range, attach it to the floor, wall or cabinet by installing the Anti-Tip Device supplied. • A risk of tip-over may exist if the appliance is not installed in accordance with these instructions. • If the range is pulled away from the wall for cleaning, service or any other reason, ensure that the Anti-Tip Device is properly re-engaged when the range is pushed back against the wall. In the event of abnormal usage (such as a person standing, sitting, or leaning on an open door), failure to take this precaution can result in tipping of the range. Personal injury might result from spilled hot liquids or from the range itself. WARNING: ELECTRICAL SHOCK HAZARD! • Use extreme caution when drilling holes into the through the wall or floor material (such as ceramic tile, hardwood, marble, etc.) • DO NOT slide range across unprotected floor. • Failure to follow these instructions may result in damage to wall or floor coverings. TOOLS NEEDED FOR INSTALLATION OF ANTI-TIP DEVICE! 1. Screwdriver, Phillips 2. Drill, electric or hand 3. Measuring tape or ruler 4. 1/8” drill bit (wood or metal wall or floor) 5. 3/16” anchors, drywall, or concrete, 2 each (not required if mounting bracket is being attached to solid wood or metal. 6. Hammer 7. Pencil or other marker IMPORTANT INSTALLATION INFORMATION • The Anti-Tip Bracket may be attached to a solid wood cabinet having a minimum wall thickness of 3/4”. MODEL A 30” 36” 48” 60” ANTI-TIP BRACKET 14-15/16” 17-15/16” 23-15/16” 24-15/16” THIS SIDE AGAINST WALL STEP 4: INSTALLING...

Dieses Handbuch ist für folgende Modelle:
Standbacköfen - Precision Series (3.36 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien