Anleitung Chauvet, modell LEDRAIN 64C
Hersteller: Chauvet Dateigröße: 628.92 kb Dateiname: LEDrain_64C_Rev01b_UM.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
. Make sure there are no flammable materials close to the unit while operating. . The unit must be installed in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces. Be sure that no ventilation slots are blocked. . Always disconnect from power source before servicing or replacing fuse and be sure to replace with same fuse source. . Secure fixture to fastening device using a safety chain. . Maximum ambient temperature (Ta) is 104° F (40° C). Do not operate fixture at temperatures higher than this. . In the event of a serious operating problem, stop using the unit immediately. Never try to repair the unit by yourself. Repairs carried out by unskilled people can lead to damage or malfunction. Please contact the nearest authorized technical assistance center. . Never connect the device to a dimmer pack. . Make sure the power cord is never crimped or damaged. . Never disconnect the power cord by pulling or tugging on the cord. . Never carry the fixture directly from the cord. Always use the hanging/mounting bracket. . Avoid direct eye exposure to the light source while it is on. C:\Documents and Settings\tw\My Documents\current manuals in progress\LED rain's\LEDrain 64C\005 - Images\Line Drawings\LEDrain.gif 2. INTRODUCTION Features . 3 or 7-channel DMX-512 LED PAR can . Operating modes: 3-channel: RGB control 7-channel: RGB, macros, run/strobe speed, automatic/sound, dimmer . Static colors and RGB color mixing with or without DMX controller . Built-in automated programs via master/slave or DMX with variable speed . Built-in sound activated programs via master/slave or DMX . Pulse effect with adjustable speed Additional Features . Additional power output: max 25 units . Double-bracket yoke doubles as floor stand Product Overview DIP Switches Power In DMX Out Power Out Fuseholder DMX In Microphone Sensitivity Adjustment Knob Microphone C:\Documents and Settings\tw\My Documents\current manuals in progress\LED rain's\LEDrain 64C\005 - Images\Line Drawings\LEDrain.gif C:\Documents and Settings\tw\My Documents\current manuals in progress\LED rain's\LEDrain 64C\005 - Images\Line Drawings\LEDrain.gif CAUTION B&W Triangle - 200x184.gif CAUTION B&W Triangle - 200x184.gif CAUTION B&W Triangle - 200x184.gif CAUTION B&W Triangle - 200x184.gif 3. SETUP AC Power This fixture runs on 100~240 VAC, 50/60 Hz. Before powering on the unit, make sure the line voltage to which you are connecting it is within the range of accepted voltages. Always connect the fixture to a switched circuit. Never connect the fixture to a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used only as a 0 to 100% switch. To determine the power requirements for a particular fixture, see the label affixed to the back plate of the fixture or refer to the fixture’s specifications chart. A fixture’s listed current rating indicates its average current draw under normal conditions. Always connect the fixture to a circuit with a suitable electrical ground. Power Linking This fixture contains power linking via the Edison outlet located in front of the power input cable. Please see the diagram below for further explanation. The maximum quantity of fixtures that may be linked is 25. Fixture 2 Fixture 1 Additional power link out The power linking shown in this document is for the Chauvet® North American version ONLY! Therefore, it is the customer’s responsibility to check with the Dealer/Distributor regarding power linking on the local version of the product. Connections and availability may change, depending on the power requirements and/or regulations of each country/region. Mounting Orientation The LEDrain™ 64C may be mounted in any safe position provided there is adequate room for ventilation. Rigging Be sure that the structure can support the weight of the fixture. Please see the “Technical Specifications” section of this manual for a detailed weight listing. Mount the fixture securely. This may be done with a screw, nut and bolt, or a hanging clamp. The hole in each bracket is 13 mm in size. When rigging consider routine maintenance and control panel access. Please see the following steps for installation. . Be sure to orient the gel frame release so that it is pointing up. Please see the diagram below for a visual reference. . If the power link out is intended to be used with multiple fixture, take into account the length of each power cable, and mount the fixtures close enough to one another to accommodate for this. . When aiming the fixtures, you may use the bracket adjustment knob. Loosen the knob, adjust to the desired angle, and then tighten the knob by turning clockwise. Do not use tools for this step, as it may cause damage. . There is a secondary portion of the bracket, which may be used primarily for floor standing positions. . Safety cables must always be used. Mounting Bracket Secondary bracket (used primarily for standing position) 4. OPERATING INSTRUCTIONS Configuring the Star...