Login:
Stimmen - 3, Durchschnittliche Bewertung: 5 ( )

Anleitung Cleveland, modell Enodis PDW-2

Hersteller: Cleveland
Dateigröße: 110.19 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Each Cooking Compartment equipped with: 60 Minute Timer; Pressure Safety Valve; Heavy-duty, free floating Door with Safety Interlock; and synchronous operating Steam Inlet and Exhaust/Drain Valves. Compartments are mounted to a Low Cabinet type base or Wall Mounted. Includes a Pressure Reducing Valve and Moisture Separator. Short Form Specifications SECT. VI PAGE 9 0707 PRESSURE STEAMERS 2 OR 3 OR 4 COMPARTMENTS DIRECT STEAM, OPEN STAND PEDESTAL BASE OR WALL MOUNTED MODELS: 2 Compartments 3 Compartments 4 Compartments cPDL-2 cPDL-3 cPDL-4 cPDW-2 cPDW-3 cPDW-4 WALL MOUNTED LOW-CABINET TYPE 1” IPS common drain. Do not connect other units to this drain. Do not use PVC pipe for drain. (NOT TO SCALE) SECT. VI PAGE 10 0707 Litho in U.S.A. • Each compartment has capacity for: Eight, 12. x 20. x 21.2. Cafeteria Pans or Six, 12. x 20. x 4. Cafeteria Pans or Four, 12. x 20. x 6. Cafeteria Pans or Four, 18. x 26. Bun Pans • Many regional, state and local codes exist and it is the responsibility of the owner and installer to com- ply with those codes. • Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are: UL, ULC, NSF, and CSA. WATER QUALITY REQUIREMENT The recommended minimum water quality standards whether untreated or pre-treated, based upon 10 hours of use per day, and a Daily Blowdown, are as follows: TOTAL DISSOLVED SOLIDS less than 60 parts per million TOTAL ALKALINITY less than 20 parts per million SILICA less than 13 parts per million pH FACTOR greater than 7.5 CHLORINE less than 30 parts per million Consult a local water treatment specialist for an on site water analysis for recommendations concerning steam generator feed water treatment (if required), in order to remove or reduce harmful concentrations of minerals. The use of highly mineralized water will mean that more frequent servicing of the steam generator will be necessary. The fact that a water supply is potable is not proof that it will be suitable for the generator. Cleveland Range reserves right of design improvement or modification, as warranted. Right - 3”, Left - 3”, Rear - 3” (12” on control side if adjoining wall or equipment is over 30” high for service access) Contact factory for variances to clearances. SECT. VI PAGE 10 0707 Litho in U.S.A. • Each compartment has capacity for: Eight, 12. x 20. x 21.2. Cafeteria Pans or Six, 12. x 20. x 4. Cafeteria Pans or Four, 12. x 20. x 6. Cafeteria Pans or Four, 18. x 26. Bun Pans • Many regional, state and local codes exist and it is the responsibility of the owner and installer to com- ply with those codes. • Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are: UL, ULC, NSF, and CSA. WATER QUALITY REQUIREMENT The recommended minimum water quality standards whether untreated or pre-treated, based upon 10 hours of use per day, and a Daily Blowdown, are as follows: TOTAL DISSOLVED SO...

Dieses Handbuch ist für folgende Modelle:
Standbacköfen - Enodis PDL-3 (110.19 kb)
Standbacköfen - Enodis PDL-4 (110.19 kb)
Standbacköfen - Enodis PDW-3 (110.19 kb)
Standbacköfen - Enodis PDW-4 (110.19 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien