Anleitung Zusammenfassung
• Distance from top of counter including manifold entrance is 7 1/2. • Electrical requirements : 110/120 volt AC, 60hz. Must be grounded. 15amp circuit required. Locate outlet below the cooktop a minimum of 5" below the countertop if not installing over an under counter oven. Locate outlet below the oven or in an adjacent cabinet when installing over an adjacent under counter oven. • Minimum clearance from top of counter to combustible material below is 4 7/16" • Countertop must be supported within 3" of cutout. • Unit may be installed over a Jenn-Air under counter oven. See page 2 for additional information Subject to change without notice. This system is designed to be updated daily if necessary. Dimension Express is not responsible for use of superseded, voided, or outdated data sheets. Because of the difficulty or impracticability of determining actual damages, liability of Dimension Express shall not exceed $50.00. Copyright © Dimension Express, 2003. 321 3 13/16" Side View (not to scale) 20 13/16" 34 7/8" 18" 36" 30" min 36" 21 9/16" Overall Dimensions Top View (not to scale) Cut-Out Dimensions Countertop View (not to scale) Cabinet Requirements Wall View (not to scale) Minimum horizontal clearance between the edge of the appliance and combustible construction extending from the cooking surface to 18" above the cooking surface is 8" (see solid areas) Top view of cutout (not to scale) 1 3/4" to centerline of pipe from back edge of cutout Gas inlet location 1 3/4" from left sideof cutout to centerline of pipe. Cooktop supplied with 1/2" NPT female inlet on regulator • NEVER reuse Data Sheets. Data Sheets are subject to change without • Call Dimension Express if you have any questions at (775) 833-3633 • notice. Dimension Express is a FREE service bureau and is updated daily, • Always refer to a current Code at a Glance or manufacturer directory • it makes far more sense to spend the time necessary to request new Data • Data Sheet codes change on the first of odd numbered months at 12:01am • Sheets for each project, as opposed to the problems, time, costs, and risks associated with reusing old Data Sheets. BN182.34 • A321B149 • • 031111 • 115727 • 89750 DIMENSION EXPRESS Fax on Demand (775) 833-3600 Additional Information: • Gas requirements : The Appliance pressure regulator supplied with this appliance is pre-set and fixed for correct outlet pressure: 5"W.C. this model is equipped for use with natural gas; 10" W.C. when converting to LP. The maximum inlet gas supply pressure for the regulator is 14" W.C. The inlet test pressure for checking the regulator must be at least 6" W.C if equipped for natural gas; 11" W.C. if converted to LP gas. • An individual gas shut-off valve must be used. • Cabinetry over cooktop : 30' minimum clearance between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet. 24" minimum when bottom of wood or metal cabinet is protected by not less than 1/4" flame retardan...
Dieses Handbuch ist für folgende Modelle:Standbacköfen - Gas Cooktops JGC8536ADB (11.27 kb)
Standbacköfen - Gas Cooktops JGC8536ADQ (11.27 kb)
Standbacköfen - Gas Cooktops JGC8536ADW (11.27 kb)