Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.3 ( )

Anleitung Dacor, modell Preference and Millennia RSE30

Hersteller: Dacor
Dateigröße: 935.96 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


C. Connecting the Green Appliance wire to a Grounded Supply wire or a Grounded Cold water Pipe – where Local Codes Permit. (All Models) 1. Separate the green and white appliance wires. 2. Connect the white appliance wire to the neutral (white) supply wire in the junction box. 3. Connect the black appliance wire to the black (L1) power supply wire in the junction box. Cable from 4. Connect the red appliance wire to the red (L2) power supply wire in the junction box. 5. Connect the green appliance wire to a grounded supply wire in the junction box or to a grounded cold water pipe. 6. If connecting to a grounded cold water pipe, a separate copper grounding wire (No. 10 minimum) must be connected to a grounded cold water pipe by means of a clamp and then to an external grounding connector screw. 6. A grounded cold water pipe must have metal continuity to electrical ground and must not be interrupted by insulating materials. Any insulating materials must be jumped with a length of No. 4 copper wire securely clamped to bare metal at both ends. Gas Connection Before sliding the range into the cabinet, connect a flexible gas connector to the gas shut-off valve previously installed on the stub out. The gas valve must be turned off during installation. Connect the flex connector to the pipe fitting at the right rear of the range. wARNINGS: 1. do not apply excessive pressure when tightening gas connections and fittings. 2. do not use teflon tape or plumber’s putty on gas flex line connections. 3. Turn all cooktop control valves to the “OFF” position. Turn on gas supply and check all lines and connections for gas leaks using a soap and water solution. do not use a flame to check for leaks. After verifying that there are no gas leaks, turn off the gas supply to the range by turning the gas shut-off valve to the “OFF” position. 4. For LP installations, the LP gas tank must have its own high pressure regulator. This is in addition to the pressure regulator provided with the range. Conduit from appliance Wire nut (4 places) Junction box RED RED GREEN GREEN WHITE WHITE BLACK BLACK Separate No. 10 (minimum) copper grounding wire Clamp must be tight on pipe power supply Metal water pipe No. 4 copper wire Clamps Bare metal Meter Connecting the appliance ground to a grounded junction box wire or grounded cold water pipe 5. The maximum gas supply pressure to the appliance gas pressure regulator must never exceed 1/2 pound per square inch (3.5kPa). NOTE: The applaince gas pressure regulator is pre-set at the factory for the type of gas intended for use with the appliance. Verify that the appliance is compatible with the type of gas available by checking the data plate located behind the inlet air cooling grill. Ranges intended for use with LP gases will have “LP” as a part of the model number. Consult your dealer if the range is not compatible with your gas supply. Installing the Range Measure from the floor to the countertop and adjust the leveling legs as required to position the top frame at the desired height, based on the cabinet and countertop installation. Carefully slide the range into position in the cutout. (The left rear leveling leg should engage the anti-tip bracket.) When the range is to be installed as a “slide-in, self rimming” (with the range top overhanging the countertop cutout), measure from the floor to the countertop. Adjust the leveling legs to position the bottom edge of the range top frame approximately 1/8” (13mm) above the level of the countertop. This will allow the range to slide over the countertop. Carefully slide the range into position in the cutout. Again, the left rear leveling leg should engage the anti-tip bracket. To lower the range onto the countertop, turn the leveling legs counterclockwise. Lower the range until the bottom of the range top just contacts the countertop. Do not allow the full weight of the range to hang on the counter. Installing the Burner Components Remove the brass burner rings, porcelain burner caps, and porcelain gates from their shipping packages. Place each burner ring onto its corresponding burner base, being certain that the five alignment tabs slide into the matching notches in the base. Set each porcelain burner cap on top of its corresponding burner ring. Place each grate onto the top frame, being certain that the rubber feet are positioned in the locating dimples. wARNING: Never attempt to operate the cooktop section of the range with any of the burner rings, burner caps or grates removed. NOTE: Prior to operating the cooktop or oven sections of the range, please read the accompanying Use and Care Manual carefully. Important safety, service and warranty information is contained within this manual. 1. The range and shut-off valve must be disconnected from the gas supply piping during any pressure testing exceeding 1/2 psi (3.5kPa). 2. The range must be isolated from the gas supply piping by closing the shut-off valve during any pressure testing at or below 1/2 ps...

Dieses Handbuch ist für folgende Modelle:
Standbacköfen - MRES30 (935.96 kb)
Standbacköfen - rsd30 (935.96 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien