Login:
Stimmen - 2, Durchschnittliche Bewertung: 3.5 ( )

Anleitung Cumberland Works, modell OMMF3500

Hersteller: Cumberland Works
Dateigröße: 2.72 mb
Dateiname: OMMF3500_web.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


The minimum floor protector material is 24 gauge sheet metal. The floor protector must extend 2” beyond each side and rear of the T-vent. 6”6” 6” 3” WARNING READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE THIS STOVE. FAILURE TO FOLLOW THE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH. DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES AND SHOULD STAY AWAY TO AVOID BUMPS TO SkIN AND/OR CLOTHING. YO UNG C HILDR EN S HOULD BE CARE F ULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE STOVE. CLOTHING AND OTHER FLAMMABLE MATERIALS SHOULD NOT BE PLACED ON OR NEAR THIS UNIT. CAUTION THIS STOVE SHOULD NOT BE USED AS THE ONLY SOURCE OF HEAT IN THE HOUSE. POWER OUTAGES AND PERIODIC MAINTENANCE WILL RESULT IN A TOTAL LOSS OF HEAT. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REqUIREMENTS IN YOUR AREA. CONTACT YOUR LOCAL AUTHORITY (SUCH AS MUNICIPALBUILDINGDEPARTMENT,FIREDEPARTMENT, FIRE PREVENTION BUREAU, ETC.)TO DETERMINETHE NEED FOR A PERMIT. kEEP COMBUSTIBLE MATERIALS (SUCH AS GRASS, LEAVES, ETC.) AT LEAST 3 FEET AWAY FROMTHE FLUE OUTLET ON THE OUTSIDE OF THE BUILDING. INSTALLATION AND REPAIR OF THIS PARLOR STOVE SHOULD BE DONE BY A qUALIFIED SERVICE PERSON. THE APPLIANCE SHOULD BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY BY A qUALIFIED SERVICE PERSON. IT IS IMPERATIVE THAT CONTROL COMPARTMENTS, BURNERS, AND CIRCULATING AIR PASSAGEWAYS OF THE STOVE BE kEPT CLEAN. PARLOR STOVE FLOOR PAD CLEARANCES 800-345-6007 Page CumberlandStoveWorks.com INSTALLATION AND OPERATION MANUAL MF3500G, MF3500S, MF3500B Models CLEARANCESTOCOMBUSTIBLESnote:these are minimum clearances to combustible walls established by the aStM testing lab.we recommend that you allow sufficient space to read the tri-X Controller and to remove the left and right side panels for maintenance purposes. 6” 6” 6” 4.5” 4.5” 2” 6”6” 6” 2” CORNERINSTALLATIONINTERIOR VERTICAL VENTSSTRAIGHTINSTALLATIONTHROUGH WALL6”6” 6” 3” 6” 6” 6” 3” 4.5” 4.5” CORNERINSTALLATIONTHROUGH THE WALL VENTSSTRAIGHTINSTALLATIONINTERIORVERTICALVENTS note: when interior vertical pellet vent is used for installation, the clearance to the back wall is determined by the vent size used. install vent at clearance specified by the vent manufacturer. take into consideration any upward turning elbows or t’s. Page 800-345-6007 CumberlandStoveWorks.com INSTALLATION AND OPERATION MANUAL MF3500G, MF3500S, MF3500B Models 800-345-6007 CumberlandStoveWorks.com Page 13 OUTSIDE AIR CONNECTION Connection to outside the house is REQUIRED for mobile home installations. Direct air access must be provided, use a Fresh Air Kit (not included). Only noncombustible pipe 2” (or greater) in diameter is approved to use for outside air connections (straight or flexible). PVC pipe is NOT approved and should NEVER be used. If the air inlet is connected to the outside, it MUST be terminated with a vertical 90. bend (down) or with a wind hood. Failure to do so could result in a burn back during high winds blowing directly up the air inlet during a simultaneous power failure. Blockage, excessive length, or extra bends in the air intake pipe will starve the stove of combustion air. A 90. bend is equivalent in restriction to approximately 30” of straight inlet pipe. MOBILE HOME Installation in a mobile home should be in accordance with the manufactured home and safety standard. Department of Housing and Urban Development (HUD) CITE: 24CFR3280.707 stating this stove must be vented to the outside. In addition to the standard installation instructions, the following requirements are mandatory for installation in a mobile home: 1. Stove must be bolted to the floor. Stove will have four tie-down straps that bolt to the feet and the floor. 2. Stove must have an outside air source. 3. Stove must be electrically grounded to the steel chassis of the mobile home. 4. All vertical chimney vents must have wall supports. 5. All exhaust systems must have a spark arrestor. WARNING DO NOT CONNECT TO ANY AIR DISTRIBUTION DUCT OR SYSTEM. do not install in a sleeping room . B C B C Mobile Home Anchor & Leg Assembly CAUTION THE OPERATION OF EXHAUST FANS SUCH AS BATHROOM FANS, ATTIC FANS, ETC. MIGHT STARVE THE PARLOR STOVE OF COMBUSTIBLE AIR CREATING A NEGATIVE PRESSURE IN THE ROOM. PROVIDE ADEQUATE VENTILATION IN THE ROOM ACCOMPANYING THE PARLOR STOVE. IF NOT, THE PRESSURE SWITCH MAY SHUT OFF OPERATION OF THE PARLOR STOVE. THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR, WALL, AND CEILING/ROOF MUST BE MAINTAINED. Tie-down Straps Bolt INSTALLATION AND OPERATION MANUAL MF3500G, MF3500S, MF3500B Models VENTING The following installation guidelines must be followed to ensure conformity with both the safety listing of this stove and to local building codes. note: where passage through a wall, or p...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien