If the appliance is connected by a plug, that the plug is easily accessible after installation (but not above the hob). The cable length should be 2 mt max for isolation safety. In models with "small type- terminal block" In mix models a cable supplied with a plug with your oven (H05VV-F3G 1.5 mm2) •■ If a cable without a plug is provided together with your oven (H05 V V-F 3G 2,5 mm2 ) Take care to connect as below: Brown cable = L (Live) Blue cable = N (Neutral) Green/Yellow cable = E (Earth ) •“ If your oven is supplied without supply cord use schema-l to choose supply cord and use schema- II for installation of cord. The cable length should be max 2m long for isolation safety. •Open the terminal block cover. •"Connect the supply cable according to wiring diagram on the rear cover. •* Fix the supply cable to main body with integrated screw via cable tightener. •* Assembly the terminal block cover to its place. Your oven is suitable for single and three phase connection. •The mains cable must pass through the cable clamp. •The mains cable should be routed away from the appliance and in parti_______ ventilation slots, the vent outlet and should not be obstructed when pushed in to position between the appliance and the wall and/or cabinet. E—l®l ,-g DU—ue—[©I 3NAC 380/400/415 V 2NAC 380/400/415 V Schema Connection Type Monophase Three phase with Neutral Two phase with Neutral Voltage 220/230/240 V 380/400/415 V 380/400/415 V Supply cord type (max 2m long) 3x4.0 mm2 H05 VV-F 5x2,5 mm2 H05 VV-F 4x2,5 mm2 H05 VV-F 3 Schema I In models with " covered terminal block" In mix models a cable supplied with a plug with your oven (H05 V V-F 3G 1 <•" If a cable without a plug is provided together with your oven (H05 VV-F3G 2,5 mm2) Take care to connect as below: Brown cable = L (Live) Blue cable = N (Neutral) Green/Yellow cable = E (Earth ) <•" If your oven is supplied without supply cord use schema-1 to choose supply cord and use schema-ll for installation of cord. The cable length should be max 2m long for isolation safety. «•* Open the terminal block cover (1). <•" Connect the supply cable according to wiring diagram on the rear cover. «•"Assembly the terminal block cover to its place. <•" The mains cable must pass through the cable clamp (2). <•" Fix the supply cable to main body with two screw via cable tightener (2). Your oven is suitable for single and three phase connection. «•"The mains cable should be routed away from the appliance and in particular ventilation slots, the vent outlet and should not be obstructed when pushed in to position between the appliance and the wall and/or cabinet. Schema I Connection Type Monophase Three phase with Neutral Two phase with Neutral Voltage 220/230/240 V 380/400/415 V 380/400/415 V Supply cord type (max 2m long) 3x4.0 mm2 H05 VV-F 5x2,5 mm2 H05 VV-F 4x2,5 mm2 H05 V V-F .5 mm2) T o-o 0-0 0*0 0-0 On-O Vom Lo«< AC 220/230/240 V T 0-0 0-0 o«o 0*0 0-0 O'hO 7*0-0 Loo -oo ^00 Loo -O'hO 3N AC 380/400/415 V 2N AC 380/400/415 V Schema Location for models having any top gas burner 750 mm 150 mm 1 150fnm U Adjacent side walls above the appliance must not be nearer to the cooker than 150 mm and should be of heat resistant material. Leave at least 750 mm clearance above the hotplates. The appliance should be located on a level surface. The two front feet can be adjusted as required. To ensure that your appliance is standing level adjust the two front feet by turning clockwise or counterclockwise until the product is in firm contact with the floor. 4 Installation of gas cookers «•^Before your appliance is connected to the gas supply, check the ensure that the gas category and pressure specifications shown in the data plate corresponds with your gas supply. If necessary call authorized service for adjusting to gas category. •"This appliance shall be installed in accordance with the regulations in force and only used in a well ventilated space. Read the instructions before installing or using this appliances. In the interest of safety this appliances must be installed and/or serviced by a competent person as stated in the gas safety regulations current editions. ** Please refer to the data plate for details about gas supply and pressures. «•* The appliance must not be installed in a room without a window or other controllable opening. If is installed in a room without a door which opens directly to tohe outside, a permanent opening is required. The air circulation should be 2 m3/h per kW of burners. Connection of the gas hose to the oven Convenient position is selected by interchanging the hose nozzle and plug according to the location of the main gas inlet valve. If you make a connection with a flexible metal hose, locate a seal between the main gas pipe. The inner diameter of the flexible hose, which the butane hose nozzle is connected, should be 6mm for the house-type gas tubes. The inner diamete...