Login:
Stimmen - 3, Durchschnittliche Bewertung: 5 ( )

Anleitung Beko, modell CE 58100

Hersteller: Beko
Dateigröße: 5.1 mb
Dateiname: Beko-CS_58000-CE_58100-CE_58200-CE_58200_S-CE_58200_C-CS_51110-Pdf-Rus.Pdf
Unterrichtssprache:ruen
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


If necessary call authorized service for adjusting to gas category. ** Please change the plastics hose just before its changing time as stoted. 2 Part Important Installation and preparation of your oven «•* Before your appliance is connected to the mains electricity supply check to ensure that the voltage and the frequency shown in the data plate corresponds with your power supply. The data plate is situated back cover of the oven, or it is situated in the front of the storage compartment and can be seen by opening the storage compartment cover or pulling the drawer. Warning! This appliance must be earthed Our company shall not held responsible for any damage caused by the utilisation of the oven without ground socket. *•* Before applying to Authorized service, have the electrical wiring of your home ready for connection. If the appliances is connected by a plug, that the plug is easily accessible after installation (but not above the hob) &*This product must only be installed by a qualified electrician eg. local electricity company to a suitable double pole control unit with a minimum contact clearance of 3 mm in all poles which should be adjacent to (but not above) the cooker in accordance with IEE regulation, Failure to observe this instruction may result in operational problems and invalidation of the product warranty. If the appliance is connected by a plug, that the plug is easily accessible after installation (but not above the hob). The cable length should be 2 mt max hr isolation safety. In models with "small type- terminal block" In mix models a cable supplied with a plug with your oven (H05 V V-F 3G 1.5 mm2) «•* If a cable without a plug is provided together with your oven (H05 V V-F 3G 2,5 mm2 ) Take care to connect as below: Brown cable = L (Live) Blue cable = N (Neutral) Green/Yellow cable = E (Earth) If your oven is supplied without supply cord use schema-1 to choose supply cord and use schema- 11 for installation of cord. The cable length should be max 2m long for isolation safety. Open the terminal block cover. Schema II **Connect the supply cable according to wiring diagram on the rear cover. «•* Fix the supply cable to main body with integrated screw via cable tightener. Assembly the terminal block cover to its place. Your oven is suitable for single and three phase connection. ^ ^ <^The mains cable must pass through the cable clamp. **The mains cable should be routed away from the appliance and ... & 4 particular ventilation slots, the vent outlet and should not be obstructed when pushed in to position between the appliance and the wall and/or cabinet._ Connection Type Monophase Three phase with Neutral Two phase with Neutral Voltage 220/230/ 240 V 380/400/ 415 V 380/400/ 415 V Supply cord type (max 2m long) 3x2,5 mm2 H05 V V-F 5x2,5 mm2 H05 V V-F 4x2,5 mm2 H05 V V-F Hj N -^ir] 1-0 3NAC 380/400/415 V 3^L1 2NAC 380/400/415 V 3 Schema I In models with " covered terminal block" In mix models a cable supplied with a plug with your oven (H05 V V-F 3G 1.5 mm2) ** If a cable without a plug is provided together with your oven (HOS V V-F 3G 2,5 mm2 ) Take care to connect as below: Brown cable = L (Live) Blue cable = N (Neutral) Green/Yellow cable = E (Earth ) *•* If your oven is supplied without supply cord use schema-1 to choose supply cord and use schema-ll for installation of cord. The cable length should be max 2m long for isolation safety. Open the terminal block cover (1). Connect the supply cable according to wiring diagram on the rear covi Assembly the terminal block cover to its place. The mains cable must pass through the cable clamp (2). Fix the supply cable to main body with two screw via cable tightener (2 Your oven is suitable for single and three phase connection. t+'The mains cable should be routed away from the appliance and in particular ventilation slots, the vent outlet and should not be obstructed when pushed in to position between the appliance and the wall and/or cabinet. Schema I Connection Type Monophase Three phase with Neutral Two phase with Neutral Voltage 220/230/ 240 V 380/400/415 V 380/400/415 V Supply cord type (max 2m long) 3x2,5 mm2 H05 V V-F 5x2,5 mm2 H05 V V-F 4x2,5 mm2 H05 V V-F Ною -> 0-0 Loo -Г0Ю Loo -QlhO AC 220/230/240 V 0-0 0-0 0-0 0*0 0-0 QihO 3N AC 380/400/415 V ~6 --рЮ-О Lo-o --0-0 -P^O^O Loo -QihO 2N AC 380/400/415 V Schema II r. I 750 mm 150\mm 1 150'lmm u Adjacent side walls above the appliance must not be nearer to the cooker than / 50 mm and should be of heat resistant material. Leave at least 750 mm clearance above the hotplates. The appliance should be located on a level surface. The two front feet can be adjusted as required. To ensure that your appliance is standing level adjust the two front feet by turning clockwise or counterclockwise until the product is in firm contact with the floor. 4 Installation of gas tookers •*Before your appliance is connected to ...

Dieses Handbuch ist für folgende Modelle:
Standbacköfen - CE 58200 (5.1 mb)
Standbacköfen - CE 58200 C (5.1 mb)
Standbacköfen - CE 58200 S (5.1 mb)
Standbacköfen - CS 51110 (5.1 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien