Login:
heruntergeladen wurde: 0   Dateigröße: 4 mb   Hersteller: Cleveland Range  
Kategorie: Dampfgarer
@name

Cleveland Range, LLC has made every effort to provide accurate information in this document, but cannot guarantee that this document does not contain unintentional errors and omissions. The information in this document may be subject to technical and technological changes, revisions, or updates. Cleveland Range, LLC assumes no liability or responsibility regarding errata, changes, revisions, or updates. Qualified Cleveland Range, LLC Authorized Service Representatives are obligated to follow ind

heruntergeladen wurde: 8   Dateigröße: 4 mb   Hersteller: Cleveland Range  
Kategorie: Dampfgarer
@name

A red light glows when electricity is on. If water level is correct steam generator will operate by pressing the “reset" button. Heaters will not work without water in the steam generator. This manual reset button must be pressed to start up the generator initially, and to restart the steam generator after every shut off. or power interruption. No attempt should be made to operate the equipment during a power failure. 8) Check to make sure that the water in the sight gauge glass automatically s

heruntergeladen wurde: 6   Dateigröße: 4 mb   Hersteller: Cleveland Range  
Kategorie: Dampfgarer
@name

by a qualified service technician. Generator descaling instructions are provided on a separate data sheet Failure to periodically remove scale from the inside of the generator will result in greatly reduced generator Bie. 4) Every steam generator is equipped with at least one corrosion resistor to reduce generator shell corrosion and scaling. This corrosion resistor is sacrificial and must be replaced at regular intervals just before it is entirely consumed. In areas where the water is very har

heruntergeladen wurde: 4   Dateigröße: 4 mb   Hersteller: Cleveland Range  
Kategorie: Dampfgarer
@name

403071 * (43828) STEAMCOIL GAS 160-200 M GAS 250-300 M SERVICE NOTE The above drawings showing the sight gauge location and method of mounting are for assisting in determining the proper part number for replacement generators. When ordering, please provide both the proper part number and the equipment’s serial number. CLEVELAND RANGE CO., 1333 EAST 179th ST., CLEVELAND, OHIO 44110 1090 LiTHO in U.S.A. Manufacturer reserves right of design improvement or modification, as warranted. Data S

heruntergeladen wurde: 4   Dateigröße: 4 mb   Hersteller: Cleveland Range  
Kategorie: Dampfgarer
@name

This procedure is recommended if the traps act sluggishly, as they may if contaminated by grease or other film. If cleaning fails to restore the trap’s proper functioning, replace the trap. For more detailed thermostatic trap servicing instructions, refer to Data Sheet 260-LH. CLEVELAND RANGE, INC., 1333 EAST 179th ST., CLEVELAND, OHIO 44110 Manuiacturer reserves right of design improvement or modification, as warranted. UTHO IN USA. 0388 7. Shelves, drain screens, and pan slides are stainle

heruntergeladen wurde: 2   Dateigröße: 4 mb   Hersteller: Cleveland Range  
Kategorie: Dampfgarer
@name

Repairs to the boiler must conform to the applicable provisions in the ASME Code or the National Board Rules for Repairs. A boiler will last many years before it has to be retired from service. Periodic inspection will reveal the approaching retirement time. It is better to schedule a convenient replacement time than to wait for the boiler to fail. When a boiler older than 10 years is replaced, the entire steam generator base assembly should be replaced for a number of reasons: — Replacement

heruntergeladen wurde: 10   Dateigröße: 4 mb   Hersteller: Cleveland Range  
Kategorie: Dampfgarer
@name

Rinse with a solution of bicarbonate of soda to neutralize any acid residue, and again, flush with water. Be sure to reconnectthe wire to the water level control board and to open the manual water feed valve. CAUTION: Never tighten the hand hole plate nut when the steam generator is in use, hot, or otherwise pressurized. Nevertighten nut over 15 footpounds torque. Overtightening may cause uneven stress, which may result in the weakening and possible breakage of the plate. CLEVELAND RANGE, INC.

heruntergeladen wurde: 1   Dateigröße: 4 mb   Hersteller: Cleveland Range  
Kategorie: Dampfgarer
@name

Super Steamcraft. or “D" Series Defroster With or Without Kettles N/A 10 psi 15 psi N/A 10 psi 10 psi 20 psi CLEVELAND RANGE, INC., 1333 EAST 179th ST., CLEVELAND, OHIO 44110 Manufacturer reserves right of design improvement y modification. as tuananted- 04SS UTHO IN U£J<. Data Sheet 260-BD-1 SERVICING INSTRUCTIONS PROBE SYSTEM: ELECTRIC WATER FILL AND ELECTRIC LOW WATER FUEL CUT OFF FOR STEAM GENERATOR — 3 PROBE TYPE WARNING: Service of the steam generator must be performed only by trai

heruntergeladen wurde: 1   Dateigröße: 4 mb   Hersteller: Cleveland Range  
Kategorie: Dampfgarer
@name

3%" 11 16833 Plunger Disc 12 43724 Water Regulator Valve Sub-Assembly 13 43895 Corrosion Resistor 14 22130 Safety Valve — 8 psi 22131 Safety Valve — 15 psi 15 22140 Air Vent 16 16820 Pigtail. Vi" ips 17 19947 Pressure Switch 1S 12161 Signal Light 115/220 Volt 19 19944 On-Off Power Switch. 115/220 Volt DPST 20 03503 Contactor for Side Heater. 50 amp. 208/240 Volt Coil 03505 Contactor for Side Heater. 75 amp. 208/240 Volt Coil 21 20532 Transformer — Optional (480/240/120 Volt Only)

heruntergeladen wurde: 1   Dateigröße: 4 mb   Hersteller: Cleveland Range  
Kategorie: Dampfgarer
@name

0388 uaa sneer zsvtx; («2} MODEL J DOOR AND DOOR ARM ASSEMBLY REFERENCE PART NUMBER NUMBER DESCRIPTION 1 253021 Door Arm W/Bushings, Polished 2 02568 Door Arm Hinge Bushing (2 Required) 3 41370 Standard Door Arm Screw With Ball (1" x 8 thread) 41371 Oversize Door Arm Screw With Ball (1%2* x 8 thread) 4 081001 Screw Handle Bar, Poiished S 16305 Pin 6 15250 Oil Cup 7 41360 Striker Plate and Pin 8 43723 Door Hanger w/Screws and Washers (2 Required) 9 53035 Door Arm Insert, Stainless





Kategorien