Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.3 ( )

Anleitung Cleveland Range, modell PEM-24-3

Hersteller: Cleveland Range
Dateigröße: 91.74 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Solid State Controls operate Water Level and Steam Generator (boiler) Safety Functions. Automatic Steam Generator (boil- er) Blowdown with additional Manual Drain Valve. p15 psi for Kettle Operation, includes Power Take-Off (PTO) pKettle Interconnecting Kit (IMK) pStainless Steel base Frame (FSS) pStainless Steel gas flue cover, insulated (SSF) pSpecial compartment Slide Racks p12” x 20” Cafeteria Pans 1”, 2 1/2”, 4” or 6” deep pIntermediate Pull-Out Shelf (POS) pSpray Head with flexible Hose (SH) pVoltages, other than standard pWater Filters pCorrectional Packages Short Form Specifications PRESSURE STEAMERS 2 OR 3 COMPARTMENTS, CABINET MOUNTED ELECTRIC STEAM GENERATOR 24, 36 OR 48 KW, 36” WIDE CABINET BASE MODELS: 2 Compartments 3 Compartments cPEM-24-2 cPEM-24-3 cPEM-36-2 cPEM-36-3 cPEM-48-2 cPEM-48-3 SECT. VI PAGE 1 0707 (NOT TO SCALE) SECT. VI PAGE 2 0707 Litho in U.S.A. • Each compartment has capacity for: Eight, 12. x 20. x 21.2. Cafeteria Pans or Six, 12. x 20. x 4. Cafeteria Pans or Four, 12. x 20. x 6. Cafeteria Pans or Four, 18. x 26. Bun Pans • Many regional, state and local codes exist and it is the responsibility of the owner and installer to com- ply with those codes. • Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are: UL, NSF, ASME/N.Bd., CSA. WATER QUALITY REQUIREMENT The recommended minimum water quality standards whether untreated or pre-treated, based upon 10 hours of use per day, and a Daily Blowdown, are as follows: TOTAL DISSOLVED SOLIDS less than 60 parts per million TOTAL ALKALINITY less than 20 parts per million SILICA less than 13 parts per million pH FACTOR greater than 7.5 CHLORINE less than 30 parts per million Consult a local water treatment specialist for an on site water analysis for recommendations concerning steam generator feed water treatment (if required), in order to remove or reduce harmful concentrations of minerals. The use of highly mineralized water will mean that more frequent servicing of the steam generator will be necessary. The fact that a water supply is potable is not proof that it will be suitable for the generator. Cleveland Range reserves right of design improvement or modification, as warranted. KW Volts Watts Ph Amps Wire 24 208 21,500 1 103.4 2 220 24,000 1 109.1 2 240 24,000 1 100.0 2 440 20,200 1 45.9 2 480 24,000 1 50.0 2 208 21,500 3 59.7 3 220 24,000 3 63.1 3 240 24,000 3 57.8 3 440 20,200 3 26.5 3 480 24,000 3 28.9 3 600 24,000 3 23.1 3 360 21,500 3 34.5 4 380 24,000 3 36.5 4 415 24,000 3 33.4 4 KW Volts Watts Ph Amps Wire 36 208 32,200 3 89.5 3 220 36,000 3 94.6 3 240 36,000 3 86.7 3 440 30,200 3 39.7 3 480 36,000 3 43.4 3 600 36,000 3 34.7 3 360 32,200 3 51.7 4 380 36,000 3 54.8 4 415 36,000 3 50.1 4 48 208 42,900 3 119.2 3 220 48,000 3 126.1 3 240 48,000 3 115.6 3 440 40,300 3 52.9 3 480 48,000 3 57.8 3 600 48,000 3 46.2 3 360 42,900 3 68.9 4 380 48,000 3 73.0 4 415 48,000 3 66.9 4 ELECTRIC WATER DRAINAGE CLEARANCED The Floor Drain must be located outside the confines of the equipment base. 1 1/2. I.P.S. common drain. Do not connect other units to this drain. Do not use PVC pipe for drain. 1/4. NPT Cold Water Inlet 35 psi minimum 60 psi maximum Right - 3”, Left - 3”, Rear - 3” (12” on control side if adjoining wall or equipment is over 30” high for service access) Contact factory for variances to clearances. SECT. VI PAGE 2 0707 Litho in U.S.A. • Each compartment has capacity for: Eight, 12. x 20. x 21.2. Cafeteria Pans or Six, 12. x 20. x 4. Cafeteria Pans or Four, 12. x 20. x 6. Cafeteria Pans or Four, 18. x 26. Bun Pans • Many regional, state and local codes exist and it is the responsibility of the owner and installer to com- ply with those codes. • Cleveland Range equipment is built to comply with applicable standards for manufacturers. Included among those approval agencies are: UL, NSF, ASME/N.Bd., CSA. WATER QUALITY REQUIREMENT The recommended minimum water quality standards whether untreated or pre-treated, based upon 10 hours of use per day, and a Daily Blowdown, are as follows: TOTAL DISSOLVED SOLIDS less than 60 parts per million TOTAL ALKALINITY less than 20 parts per million SILICA less than 13 parts per million pH FACTOR greater than 7.5 CHLORINE less than 30 parts per million Consult a local water treatment specialist for an on site water analysis for recommendations concerning steam generator feed water treatment (if required), in order to remove or reduce harmful concentrations of minerals. The use of highly mineralized water will mean that more frequent servicing of the steam generator will be necessary. The fact that a water supply is potable is not proof that it will be suitable for the generator. Cleveland Range reserves right of design improvement or modification, as warranted. KW Volts Watts Ph Amps Wire 24 208 21,500 1 103.4 2 220 24,000 1 109.1 2 240 24,000 1 100.0 2 440 20,200 1 45.9 2 480 24,000 1 50.0 2 208 21,500 3 59.7 3 220 24,00...

Dieses Handbuch ist für folgende Modelle:
Dampfgarer - PEM-24-2 (91.74 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien