Login:
Sortierung : Dateiname ↑   heruntergeladen   Bewertung   Dateigröße ↑  
heruntergeladen wurde: 0   Dateigröße: 177 kb   Hersteller: Danby  
Kategorie: Entfeuchter
@name@name

DIRECT DRAIN NOTE: The drain hose is not included with the unit. The direct drain feature is intended FEATURE for use in basements inclusive of a floor drain only. NOTE: Do not attempt to operate the direct drain feature using drain/stem pipes above ground level. CONNECTING THE DIRECT DRAIN: 1) Remove (cut away) drain cover located at the rear of the unit (see Fig. 3) and remove the water tank located at the front of the unit. 2) Cut provided drain hose (O 13.5mm/0.53in.) to required length (to

heruntergeladen wurde: 0   Dateigröße: 258 kb   Hersteller: Danby  
Kategorie: Entfeuchter
@name@name

The nameplate contains electrical and other technical data specific to this unit. 5) To avoid the possibility of personal injury, always disconnect the power supply before attempting to clean and/or service the unit. UNIT SPECIFICATIONS Model Number: DDR2509EE DDR3009EE DDR4009EE Dehumidifying Capacity (Pints / Liters) 25 / 11.8 30 / 14.2 40 / 18.9 Electrical Requirements 115 Volts / 60 Hz 115 volts / 60 Hz 115 volts / 60 Hz Power Input (Watts) 380 420 525 Rated Amperage (Dehumidifying) 3.8 4.2

heruntergeladen wurde: 0   Dateigröße: 719 kb   Hersteller: Danby  
Kategorie: Entfeuchter
@name

IMPORTANT: Never operate the unit without the air filter in place. AIR FILTER CLEANING STEPS: 1) Pull the air filter out gently (Fig. 4). 2) Clean the filter with a vacuum cleaner, or wash it with clean water and dry with a dry cloth. 3) Put the clean air filter back in place and continue to operate the dehumidifier. Fig. 4 Fig. 5 9 CONTINUOUS DRAIN INSTRUCTIONS When using the continuous drain function, the PVC hose must be placed horizontally INSTALLING PVC below the drainage hole. Avoid uneven

heruntergeladen wurde: 0   Dateigröße: 177 kb   Hersteller: Danby  
Kategorie: Entfeuchter
@name@name

NOTE: The LED readout is programmed to default to display the ambient relative humidity conditions. To view the Set Operating Relative Humidity Value, press the “up” or “down” button (once) and the set RH operating value will flash for approximately 5 seconds in the LED window, then revert back to display the internal RH value. 2) ON/OFF Button: Each time this button is pressed the unit turns ON (adjacent indicator light illuminates) orOff (adjacent indicator light is not illuminated) 3) CONTINU

heruntergeladen wurde: 0   Dateigröße: 250 kb   Hersteller: Danby  
Kategorie: Entfeuchter
@name@name

PRECAUTION: Veuillez lire attentivement les consignes de securite et les directives d’utilisation avant l’utilisation initiale de ce produit. CAUTION: Read and follow all safety rules and operating instructions before first use of this product. PRECAUTION: Veuillez lire attentivement les consignes de securite et les directives d’utilisation avant l’utilisation initiale de ce produit. PORTABLE DEHUMIDIFIER Owner’s Use and Care Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

heruntergeladen wurde: 0   Dateigröße: 739 kb   Hersteller: Danby  
Kategorie: Entfeuchter
@name@name

: Used to adjust Clock and Timer On/Off settings backward (1 min./1hr. increments). Used to adjust Temperature settings backward (1°C / °F increments). Note: This appliance allows you select the temperature scale displayed in either “Celsius” or Fahrenheit” according to your preference. To change temperature scale displayed on the control panel display, press both the “Temp/Timer” adjust arrows simultaneously to alternate between “Celsius” & “Fahrenheit”. TIMER ON : Used to initiate the AUTO ON

heruntergeladen wurde: 0   Dateigröße: 1 mb   Hersteller: Danby  
Kategorie: Entfeuchter
@name

Danby OWNER'S MANUAL MANUEL D'UTILISATION Model • Modèle DDR3008EE DDR4588EE DDR6588EE CAUTION: Read complete installation and operating instructions before installing and/or using the dehumidifier. ATTENTION : Lire attentivement les consignes de sécurité et les instructions d'utilisation avant l'utilisation initiale de ce produit. KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE. If the Dehumidifier changes ownership, be sure this manual accompanies the unit. CONSERVER CES INSTRUCTIONS

heruntergeladen wurde: 3   Dateigröße: 259 kb   Hersteller: Danby  
Kategorie: Entfeuchter
@name@name

2 FACTORY Each time the unit is disconnected/re-connected and/or in the event of a power failure, DEFAULT SETTING the electronic circuitboard automatically defaults to the following factory setting: Humidity Setting: 60%program setting was different from the above (defaultFan Speed: Low setting) it will be necessary to re-program your settings.When the unit is switched “Off” manuallyNOTE: In the event of a power failure, all previous(using the on/off keypad) the unit will always defaultsettings

heruntergeladen wurde: 1   Dateigröße: 250 kb   Hersteller: Danby  
Kategorie: Entfeuchter
@name@name

Keep all doors and windows closed. FEATURES • Soft touch (Electronic) Control Key Pads • Full Bucket Indicator Light • Auto-Sensing Humidity Control • Easy Roll Castors (4) • Adjustable Humidity Settings (35% - 80%) • Front Mounted Water Tank (Removable) • 2 Fan Speed Settings (High / Low) • Direct Drain Option (HOSE NOT INCLUDED) • Delay Start Protection (Compressor) • Quiet Operation • Auto-Defrost (De-Icer) • Removable Air Filter Control Panel Handle Moist Air Intake Air Filter Drain Bucket C

heruntergeladen wurde: 0   Dateigröße: 8 mb   Hersteller: Danby  
Kategorie: Entfeuchter
@name@name

1. NE JAMAIS utiliser d’essence, benzene, de peinture, diluant ou autre compose chimique pour nettoyer cet appareil; toutes ces substances feront subir des dommages ou deformations aux composants de plastique et degraderont la finition. 2. Ne jamais verser de l’eau directement sur l’appareil; ceci pourrait faire subir des dommages aux composants electriques et a l’isolant des conducteurs electriques. 3. Utiliser uniquement de l’eau tiede, un detergent pour lavevaisselle et un chiffon doux pour e