Anleitung Kenmore, modell 580.5145
Hersteller: Kenmore Dateigröße: 322.1 kb Dateiname: 4ee04af9-866f-45a6-8cea-64a6e4079450.pdf
Unterrichtssprache:
|
|
|
|
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite
Anleitung Zusammenfassung
At temperatures below this, the coils can become covered with frost. (_65" F NOTE: If frost occurs, the unit will cycle on and off. This is normal. Unplug the unit (or turn the unit off) until the frost melts and the room temperature rises. (18"c) DEFROST CONTROL -65°F When the defrost control senses frost build-up on the evaporator coil, it will automatically shut off the compressor. The fan will continue to run to draw air across the coil and melt the frost. When the coil is defrosted, the compressor will automatically restart and dehumidifying resume. g8"c) • Use the dehumidifier in a basement prevent moisture damage. to help • Use the dehumidifier in cooking, bathing, and dishwashing areas excessive moisture. laundry, that have • Use the dehumidifier to prevent moisture damage anywhere books or valuables are stored. -7 Whenthebucketisfull,orwhenthebucketisnotintheproperposition,theBucketFulrlightturnson andtheunitautomatically shutsoff. Also,whenbucketisoutofposition,theunitwillbeep3times. Thebucketmustbereplacedintheproperpositionforthedehumidifierto work.Thelightwill beonandthedehumidifierwill notrunifthebucketisnotintheproperposition. The water bucket can be emptied Empty the bucket manually. When the bucket is full, remove and empty it into a large sink or tub. When finished, replace it properly. NOTE: To replace the bucket properly, make sure the slots on the back of bucket are positioned correctly. in one of three ways: Place the dehumidifier directly over drain. The bucket has a threaded hose connection which can be left open. Drill a 1/4" (6.4ram) to 1/2"(13mm) hole in the center of the hose connection. Once opened, the hose connection will continually drain water from the bucket. Attach a garden hose to the threaded bucket drain hose connection to carry water to the drain. (HANDTIGHTENONLY) When being attached to the bucket drain hose connection, be sure the hose doesn't kink or bend. It should lie fiat from the dehumidifier to the drain. -8o GRILLE AND CASE To clean the case: Use water and a mild detergent. Do not use bleach or an abrasive cleaner. To clean the grille: Use a vacuum with an attachment or brush. AIR FILTER The air filter is on the back of the dehumidifier. It should be checked and cleaned at least every 30 days or more often if necessary. TO REMOVE: Flex the filter at the lower right corner and slide the upper right side to the left. Release all of the tabs and remove the filter. Wash it in warm soapy water. Rinse and let the filter dry before replacing it. CLEANING INSIDE THE UNIT After removing the air filter, clean the coil on the inside with a soft brush to remove any soft and wet soil. NOTE: Do not allow water to enter the electrical/machine compartment through the circular opening behind the coil. Do not spray the coil with a hose. GENERAL CLEANING • Dust the front grille and the side panels with a soft brush or use the dusting attachment of your vacuum. • If cabinet paint chips, you can touch up the paint with a good grade enamel to prevent rust. WATER BUCKET CLEANING • Every few weeks, rinse the inside of the water bucket with a mild detergent to prevent growth of mold, mildew, and bacteria. / -9 Problem<..:i_, Dehumidifier does not start Dehumidifier does not dry the air as it should Dehumidifier runs too much Frost appears on the coils Fan noise Water on floor ,_ _Possuble Causes >_ v,,=_ ,-_.,--._-_m,_ -,_ " The dehumidifier power cord is unplugged The fuse is blown or circuit breaker is tripped, Water bucket is full Bucket is not installed. Did not allow enough time to remove the moisture, Airflow is restricted. The Humidity Control may not be set low Humidity. Doors and windows may not be closed tightly, Clothesdryermaybe blowing moisture-ladenairIntotheroom. Room temperature is too low. Area to be dehumidified is too large, Doorsandwindowsare open. Dehumidifier has been recently turned on or room temperature is below 65°F. (18°C.). Air is moving through the dehumidifier. Bucket drain hose connection may be loose. Water bucket is not all the way in. _ . ._,wnat-o Do --_ '_,,_._. -,,_:,_,_ ...... ..,r,-'_.,,_ •' " • Make sure the dehumidifier plug is pushed completely into the outlet. • Check the house fuse or circuit breaker box and replace the fuse or reset the breaker • The dehumidtfier automatically turns off when th_s occurs Empty the bucket. • Make sure a bucket in the right place • When first installed, allow at least 3 or 4 days to maintain the desired dryness. • Make sure there are no curtains, blinds or furniture blocking the front or back of the dehumidifier. o Press the O Humidity Control button to lower the humidity. • Check that all doors, windows and other openings are securely closed. • Install the dehumidifier away from the dryer. The dryer should be vented to the outside. • The unit will not operate satisfactorily if the room temperature is below 65°F. (18°C.) • Check with your dealer to see if the capacity is adequate • Close all doors and windows ...