mAINTENANCE Dehumidifier AIR FILTER Under normal circumstances, the filter in the dehumidifier should be cleaned or replaced once a year. A clean filter is necessary to prevent damage to the dehumidifier and allow it to function at full capacity. To remove the filter, first unplug or disconnect power to the dehumidifier, then remove the air filter via the access panel on the side of the dehumidifier. To clean, flush with warm water and detergent solution. After a clean or new filter is reinstalled, replace the access panel and reconnect power to the dehumidifier. The replacement filter for the dehumidifier is Model 4510 and is available from most HVAC contractors in your area or Aprilaire.com DRAIN The drain trap or outlet should be checked and cleaned of debris annually. NOTE: The drain trap needs to be primed with water prior to start-up and after extended periods of unit shut down (winter months). VII. LImITED WARRANTy Your Research Products Corporation Aprilaire® Dehumidifier is expressly warranted for five (5) years from date of installation to be free from defects in materials or workmanship. Research Products Corporation’s exclusive obligation under this warranty shall be to supply, without charge, a replacement for any component which is found to be defective within such five (5) year period and which is returned not later than thirty (30) days after said five (5) year period by you to either your original supplier or to Research Products Corporation, Madison, Wisconsin 53701, together with the model number and installation date of the dehumidifier. THIS WARRANTY SHALL NOT OBLIGATE RESEARCH PRODUCTS CORPORATION FOR ANY LABOR COSTS AND SHALL NOT APPLY TO DEFECTS IN WORKMANSHIP OR MATERIALS FURNISHED BY YOUR INSTALLER AS CONTRASTED TO DEFECTS IN THE DEHUMIDIFIER ITSELF. IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED IN DURATION TO THE AFORESAID FIVE YEAR PERIOD. RESEARCH PRODUCTS CORPORATION’S LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, OTHER THAN DAMAGES FOR PERSONAL INJURIES, RESULTING FROM ANY BREACH OF THE AFORESAID IMPLIED WARRANTIES OR THE ABOVE LIMITED WARRANTY IS EXPRESSLY EXCLUDED. THIS LIMITED WARRANTY IS VOID IF DEFECT(S) RESULT FROM FAILURE TO HAVE THIS UNIT INSTALLED BY A QUALIFIED HEATING AND AIR CONDITIONING CONTRACTOR. IF THE LIMITED WARRANTY IS VOID DUE TO FAILURE TO USE A QUALIFIED CONTRACTOR, ALL DISCLAIMERS OF IMPLIED WARRANTIES SHALL BE EFFECTIVE UPON INSTALLATION. Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages so the above exclusion or limitations may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. WARRANTy REgISTRATION Please… Take a few minutes to visit us online at to register your Aprilaire product. If you do not have on-line access, please mail a postcard with your name, address, phone number, email address, product purchased, model number, date of purchase and dealer name and address to: Research Products Corporation P.O. Box 1467 Madison, WI 53701 Thank you! your Warranty Registration information will not be sold or shared outside of this company. RESEARCH PRODUCTS CORPORATION 1015 E. Washington avE. • Madison, Wi 53703 • PhonE: 608/257-8801 • Fax: 608/257-4357 • 10007974 9.09 B2204572B Model 1710A Dehumidifier Installation & Owner’s Manual Includes Safety & Operating Instructions and Warranty Information READ AND SAVE THESE INSTRUCTIONS WARNINg CAUTION 120 volts may cause serious injury from electric shock. Disconnect electrical power before servicing. Do not use solvents/cleaners on or near the control board. Sudden operation may cause personal injury or property damage. Unplug the dehumidifier before servicing. Unit weight and dropping may cause personal injury or equipment damage. Handle with care. Corrosive environments can damage electrical equipment. Do not use in pool applications. INSTALLER – PLEASE NOTE! 1. INSTALLATION mUST CONFORm TO ALL APPLICAbLE STATE OR LOCAL CODES. 2. A 15 Amp circuit is required for proper operation of the dehumidifier. Do not use an extension cord. 3. For protection of the compressor, unit must be transported and installed in an upright position. If the unit was shipped or stored on its side, a 24 hour settling period is required before running the unit. I. PRINCIPLE OF OPERATION The purpose of the Aprilaire® Dehumidifier is to keep humidity in a space at acceptable limits to reduce the unwanted effects of high humidity. The dehumidifier measures the condition of the air in the space to decide when to run. IV. OPERATINg INSTRUCTIONS II. SPECIFICATIONS IV. OPERATINg INSTRUCTIONS II. SPECIFICATIONS Dimensions: 203/4” W x 24” L x 20 3/8”–23 5/8” H Design Airflow: 275 CFM @ 0.6 in. w.c. Weight: 93 lbs. Filter: MERV 8 Filter Capacity: 90 pints per day @ 60%RH, 80.F Cabinet Insula...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien