Login:
Stimmen - 2, Durchschnittliche Bewertung: 3.5 ( )

Anleitung Honeywell, modell H46C

Hersteller: Honeywell
Dateigröße: 147.14 kb
Dateiname: 7e74eb00-580a-49e7-a96c-d637582e7164.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


3. Installer must be a trained, experienced service technician. 4. After installation is complete, check out product operation as provided in these instructions. CAUTION Electrical Shock Hazard. Can cause electrical shock or equipment damage. Disconnect power supply before connecting wiring. Location Select a location about 5 ft (1.5m) above the floor in an area with good circulation at average temperature and humidity for the area to be controlled. Avoid locations near hot or cold air ducts and discharged air from the controlled equipment. Mounting 1. Remove the setting knob. 2. To remove cover, pull cover forward from device. 3. Install a 2 in. x 3 in. (51 mm x 76 mm) vertical switch box at the selected location. 4. Using the two screws provided, fasten the adapter plate to the switch box, as shown. 5. Pull the wires from the switch box through the opening in the adapter plate and connect to the H46 leadwires with the solderless connectors provided. See Fig. 2 and 3 for typical hookup. 6. Push the wires back into the switch box. 7. Place the H46 against the adapter plate, making certain the tab at the bottom of the plate fits into the notch on the H46. 8. Fasten the H46 to the adapter plate by tightening the captive screw. 9. Replace the cover and the setting knob. 2 X 3 IN. H46 (COVER OFF) H46 CAPTIVE MOUNTING SCREW ADAPTER PLATE SCREWS (2) SWITCH BOX NYLON ELEMENT H46 LEADWIRES (2) PLATE TAB ADAPTER PLATE WALL SURFACE M7907 Fig. 1. Mounting H46C on vertical switch box. Wiring Disconnect power supply before connecting wiring to avoid electrical shock or equipment damage. All wiring must comply with local codes or equipment damage. All wiring must comply with local codes and ordinances. Do not exceed contact and coil ratings when wiring into system. See Fig. 2. ® U.S. Registered Trademark Copyright © 2003 Honeywell International Inc. • • All Rights Reserved 95-5367-4 H46C HUMIDITY CONTROLLER H46C HUMIDITY CONTROLLER RISE DEHUMIDIFIER L1 EXHAUST FAN (HOT) 1 1 OR AIR POWER CONDITIONER SUPPLY L2 PROVIDE DISCONNECT MEANS AND OVERLOAD M7923 PROTECTION AS REQUIRED. Fig. 2. Typical H46C wiring diagram. Connections and Operation A dehumidistat in combination with the thermostat can be used to run the air conditioner to control relative humidity levels. The dehumidistat and thermostat can be wired in parallel or in series. Wiring in parallel allows the dehumidistat to independently control the humidity level, but could cause overcooling of the home. During unoccupied times, the homeowner should set the thermostat to a relatively high setting and control moisture using the dehumidistat. Wiring in series prevents overcooling but the air conditioner runs only when both the thermostat and dehumidistat are calling. During unoccupied times, the homeowner should set the thermostat to a relatively low setting and control moisture using the dehumidistat. SETTING AND ADJUSTMENT The H46 makes contact on a relative humidity rise to the setpoint to start the dehumidifier. On a decrease in relative humidity to the setpoint (minus the differential), the switch breaks contact to stop the dehumidifier. Turn the knob clockwise to the setting stop to place the H46 in the On position. Turn the knob counterclockwise to the setting stop to place the H46 in the Off position. CHECKOUT After completing all mounting and wiring, turn on the power supply. Place the system into operation by turning the setting knob toward the low end of the scale until the dehumidifier motor starts. Turn the setting knob slowly toward the high end of the scale until the dehumidifier motor stops. H46C T87F/Q539A INTERNALSCHEMATIC TEMPERATURE FALL 1 2 3 PROVIDE OVERLOAD PROTECTION AND DISCONNECT MEANS AS REQUIRED. HEATING DAMPER MOTOR, IF USED. CLOGGED FILTER SWITCH OR COOLING PANEL CONNECTION. 1 3 2 BX O R1 W Y W1 Y1 G RHR HEAT OFF FANAUTO ONCOOL HEAT OFF COOL FIXED COOL ANTICIPATOR ADJUSTABLE HEAT ANTICIPATOR HEATING RELAY OR VALVE COIL COOLING CONTACTOR COIL FAN RELAY COIL FILTER LIGHT T87F M7913 Fig. 3. Typical parallel wiring hookup for H46C with T87F/Q539A combinationfor dehumidification and mildew control. 95-5367-4 2 H46C HUMIDITY CONTROLLER H46C T87F/Q539A INTERNALSCHEMATIC TEMPERATURE FALL 1 2 3 PROVIDE OVERLOAD PROTECTION AND DISCONNECT MEANS AS REQUIRED. HEATING DAMPER MOTOR, IF USED. 3 2 BX O R1 W Y W1 Y1 G RHR HEAT OFF FANAUTO ONCOOL HEAT OFF COOL FIXED COOL ANTICIPATOR ADJUSTABLE HEAT ANTICIPATOR HEATING RELAY OR VALVE COIL COOLING CONTACTOR COIL FAN RELAY COIL FILTER LIGHT T87F CLOGGED FILTER SWITCH OR COOLING PANEL CONNECTION. 1 M7914 Fig. 4. Typical series wiring hookup of H46C with T87F/Q539A combinationfor dehumidification and mildew control. 3 95-5367-4 H46C HUMIDITY CONTROLLER Automation and Control Solutions Honeywell International Inc. Honeywell Limited-Honeywell Limitee 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Scarborough, Ontario M1V 4Z9 Printed in U.S.A. on recycled 95-5367-4 G.H. Rev. 07-03 paper containing a...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien