• Check the house fuse or circuit breaker box and replace the fuse or reset the breaker. • The dehumidifier automatically turns off when this occurs. Empty the bucket. • Make sure the bucket is in the right place. • Lower the humidity setting. • When first installed, allow at least 3 or 4 days to maintain the desired dryness. • Make sure there are no curtains, blinds or furniture blocking the front or back of the dehumidifier. • Press the _ Humidity Control button to lower the humidity. • Check that all doors, windows and other openings are securely closed. • Install the dehumidifier away from the dryer. The dryer should be vented to the outside. • The unit wilI not operate at maximum capacity if the room temperature is below 65°R (18°C.). • Check with your dealer to see if the capacity is adequate. • Close all doors and windows to the outside. • This is normal. Frost will usually disappear within 60 minutes. • This is normal. • Check the hose if one is attached. • See Removing and Emptying The Water Bucket. • Change the humidity setting. • Change the humidity setting. Owner's Manual 15 Friedrich FRIEDRICH AIR CONDITIONING CO, Posf Office Box ] 540 • San Anfonio, Texas 78295-1540 (210) 357-4400 * FAX (210) 357-4490 DEHUMIDIFIER LIMITED WARRANTY FIRST YEAR ANY PART: If any part supplied by FRIEDRICH fails because of a defect in wolkmanship ol rnaterial within twelve months from date of original purchase, FRIEDRICH will repair the product at no charge, provided dehumidifier is reasonably accessible for service. Any additional labor cost for removing inaccessible units and/or charges for mileage related to travel by a Service Agency that exceeds 25 miles one way will be the responsibility of the owner. This remedy is expressly agreed to be the exclusive remedy within twelve months from the date of the original purchase. SECOND THROUGH FIFTH YEAR SEALED REFRIGERANT SYSTEM: If the sealed refrigelation system (defined fol this pulpose as the compressor, condenser coil, evaporator coil, reversing valve, check valve, capillary, filter drier, and all interconnecting tubing) supplied by FRIEDRICH in your dehumidifier fails because of a defect in workmanship or material within sixty months from date of purchase, FRIEDRICH will pay a labor allowance and parts necessary to repair the Sealed Refrigeration System; PROVIDED FRIEDRICH will not pay the cost of diagnosis of the problem, removal, freight charges and transportation of the dehumidifier to and from the Service Agency, and the reinstallafion charges associated with repair of the Sealed Refrigeration System. All such cost will be the sole responsibility of the owner. This remedy is expressly agreed to be the exclusive remedy within sixty months flora the date of the original purchase. APPLICABILITY AND LIMITATIONS: This warranty is applicable only to units retained within the Fifty States of the U.S.A., District of Columbia, and Canada. This warranty is not applicable to: 1. All filters ol fuses. 2. Products on which the model and serial numbels have been lemoved. 3. Products which have defects or damage which results from improper installation, wiring, electrical current characteristics, or maintenance; or caused by accident, misuse or abuse, fire, flood, alterations and/or misapplication of the product and/or units installed in a corrosive atmosphere, default or delay in performance caused by war, government restrictions or restraints, strikes, material shortages beyond the control of FRIEDRICB, or acts of God. OBTAINING WARRANTY PERFORMANCE: Service will be provided by the FRIEDRICH Authorized Dealer or Service Organizatior, in your area. They are listed inthe Yellow Pages.If assistance is required in obtaining warranty performance, write to: Room Air Conditioner Service Manager, Fdeddch Air Conditioning Co., RO. Box 1540, San Antonio, TX 78295-1540. LIMITATIONS: THIS WARRANTY IS GIVEN IN LIEU OF ALL OTHER WARRANTIES. Anything in the warranty not with standing, ANY IMPLIED WARRANTIES OF FITNESS FOR PARTICULAR PURPOSE AND/OR MERCHANTABILITY SHALL BE LIMITED TO THE DURATION OF THIS EXPRESS WARRANTY. MANUFACTURER EXPRESSLY DISCLAIMS AND EXCLUDES ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGE FOR BREACH OF ANY EXPRESSED OR IMPLIED WARRANTY. NOTE: Some states do not allow limitations on how long an implied walranty lasts,or do not allow the limitation or exclusion of consequential or incidental damages,so the foregoing exclusions and limitations may not apply to you. OTHER: This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. PROOF OF PURCHASE: Owner must provide proof of purchase in order to receive any warranty related services. All service calls for explaining the operation of this product will be the sole responsibility of the consumer. All warranty service must be provided by an Authorized FRIEDRICH Service Agency, unless authorized by FRIEDRICH prior to repairs being made. In case of questions r...

Dieses Handbuch ist für folgende Modelle:
Entfeuchter - D30C (875.14 kb)
Entfeuchter - D40C (875.14 kb)
Entfeuchter - D50C (875.14 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien