Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.7 ( )

Anleitung Kenmore, modell 251.50701

Hersteller: Kenmore
Dateigröße: 1.2 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


6 CHOOSING THE PROPER LOCATION AUTOMATIC SHUT OFF Use the dehumidifier: When the bucket is full, or when the buck et is not in the proper position, the Bucket in the basement to help prevent moisture Full light goes on and the unit automati damage. cally shuts off. in the kitchen, laundry room, bathroom, The bucket must be placed in the and spa/exercise areas that have exces proper position for the dehumidifier to sive moisture. work. The light will stay on and the dehuto prevent moisture damage anywhere midifier will not run if the bucket is not in books or valuables are stored. the proper position. during construction or remodeling to The dehumidifier will shut off once the reduce drying time for drywall and paint desired humidity setting is reached plus or however check and clean filter often. minus 5% Relative Humidity(RH). WARNING To reduce the risk of fire, electric shock or injury to persons, read the important SAFETY INSTRUCTIONS found on page 3 before operating this appliance. HANDLE ............... CONTROL m • PANEL m GRAVITY DRAIN FRONT GRILL CASTER BUCKET @Mlcroban ° antimicrobial prodllct {_otectiorl Microban ® antimierobial protection inhibits the growth of odor causing bacteria on the dehmnidifier Bucket MI(ROBAN is a registered trade '-...................... AIRINLET mark of Microban h-c, dttet s Cklmpany. FILTER Model: 50501/50701 25012/25013 7 ® ®® ® ® ®®®® ® ®®® ® POWER ON/OFF (1) Cycle Timer Setting (10) Pressing Power button once turns the In this setting, the unit will run for dehumidifier "ON" and pressing it again either 3, 6, or 12 hours, then shut offfor 3, 6, turns the dehumidifier "OFF." or 12 hours. Cycle time can be adjusted by pushing the timer arrow up or down (4/5) Setting (2) repeatedly to set operating time for 3, 6, or By pressing this button, unit will cycle through 12 hours. The cycle timer function will continue each setting with every press. The order d until you change the setting or turn the unit off. settings are Humidity -Cycle Timer-Delay Start -Humidity ... Delay Start (11) Unit can be programmed to turn on at a desired Humidity (9) delay time by pushing the timer arrow and key When the unit is turned on, the unit will default (4/5). Time can be adjusted in 1 hour increments to Humidity mode. In this setting, Humidity ranging from 1 to 12 hours. Delay time will be allows you to manually set the desired humidity shown in window (8) and will count down to level by using the humidity arrow or key (4/5). start time in 1 hour increments. Humidity values are changed in 5% increments ranging from 35% to 70%. Humidity is shown FAN SPEED (3) in window (8). When pressing v arrow key Press Fan Speed to toggle between Low and when the value is 35%, the unit will operate High fan speeds. Speed will be shown in continuously, tn this continuous operation, Lo FAN SPEED INDICATOR (6). will be displayed in the window (8). To leave continuous operation, press the arrow up or BUCKET FULL INDICATOR (7). change the setting. When the collection bucket is full, BUCKET FULL indicator (7) will come on. The dehumidifier will not run until the bucket is empty. IMPORTANT: When the unit is turned off and restarted, the unit will operate at the previous operation setting, NOTICE: A power failure will require the unit to be turned back on manually and adjusted to the desired setting. 8 ® POWER ON/OFF (1) Pressing Power button once turns the dehumidifier "ON" and pressing it again turns the dehumidifier "OFF." Setting (2) By pressing this button, unit will cycle through each setting with every press. The order of settings are Auto -Humidity -Cycle Timer- Delay Start -Auto ... Auto (9) When the unit is turned on, the unit will default to Auto mode. AUTO (9) and "50%" humidity value will be displayed in window (8). In this setting, humidity level is automatically set for 50% RH. Because lower temperatures usually correlate with lower humidity levels, the unit will not run frequently. At higher temperatures higher humidity is normal so the unit will run more often. Humidity (9) Inthissetting, Humidityallowsyouto manuallyset the desired humidity level by using the humidity V arroworkey(4/5).Humidityvaluesarechanged in 5% increments ranging from 35% to 70%. Humidityisshown inwindow...

Dieses Handbuch ist für folgende Modelle:
Entfeuchter - 251.25011 (1.2 mb)
Entfeuchter - 251.25012 (1.2 mb)
Entfeuchter - 251.25013 (1.2 mb)
Entfeuchter - 251.50351 (1.2 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien