Anleitung Zusammenfassung


The green status light below the control setting flashes when the dehumidifier is circulating the air. If the humidity of the air is higher than the setting, the compressor turns on and the green Status light is lit continuously. The dehumidifier turns off after the humidity level of the air has dropped below the setting. Optional – Heating and Cooling System Blower Operation Your installing contractor may have configured the dehumidifier to turn on the heating and cooling system blower when the dehumidifier turns on to allow for improved circulation of the dry air. How Does the Optional Ventilation Work? With the ventilation option installed (if you are unsure if this option has been installed, contact your installing contractor), the dehumidifier will bring in outside air for the amount of time set on the Cycle Time adjustment during the set Cycle Period. Your dehumidifier will work with your heating and cooling system blower to satisfy the ventilation requirements that have been set. For example, if the Cycle Time is set for 20 minutes and the Cycle Period for 1 hour, you will get outdoor air introduced to your home for 20 minutes every hour. When your heating and cooling system blower operates the dehumidifier blower will turn on and will open a normally-closed damper in the duct that brings in outdoor air. If it is getting close to the end of the Cycle Period and your heating and cooling system blower has not operated, the dehumidifier will turn on the system blower. Using the 20 minute per hour settings as an example, if the heating or cooling comes on for only 10 minutes, the dehumidifier control will turn on the system blower for the final 10 minutes of the 1-hour cycle period to deliver the required amount of fresh air. Outdoor air that is brought in will mix with the air circulating through your heating and cooling system. The dehumidifier will continuously monitor the mixed air and if the humidity level gets higher than the setting, it will turn on the compressor to remove the moisture. An outdoor sensor, if installed with the ventilation option, will monitor the temperature of the outdoor air and if the temperature exceeds 100°F (38°C) or drops below 0°F (-18°C) ventilation will not occur. If the outdoor temperature is between 20°F (-7°C) and 0°F (-18°C), ventilation will only occur when your heating system operates. 90-1561 3 CAUTION Do not use spray solvents or cleaners on or near the inlet side of the dehumidifier. If desired, apply cleaner to a cloth and use to clean the cabinet. Maintenance Clean or Replace the Air Filter After initial installation, check the air filter after 6 months. If it appears matted with dust, pet hair or other debris, maintain a 6-month cleaning schedule. If it appears clean or lightly loaded, maintain a 12-month cleaning schedule. Replacement filters are Aprilaire Part No. 4510 and can be purchased from your installing contractor. Filter Cleaning Procedure 1. Turn the ON/OFF switch OFF. 2. Remove the filter access door from either side of the dehumidifier. 3. Slide the filter out of the dehumidifier. 4. Flush the filter with warm water and a mild detergent solution. 5. Shake off the excess water from the filter. 6. Replace the filter – make sure the filter seats in both the top and bottom filter rails. 7. Replace the filter access door. 8. Turn the ON/OFF switch ON. Check the Drain The drain should be checked annually to ensure there is no blockage or air lock in the drain system. If the unit is not properly draining, have it checked by a qualified service professional. Procedure to Check Drain System 1. Turn the ON/OFF switch OFF. 2. Remove the filter access door from either side of the dehumidifier. 3. Slide the filter out of the dehumidifier to expose the evaporator coil. 4. Slowly pour a pint of water into the dehumidifier drip pan near the bottom of the evaporator coil so that the water flows into the drain pan. 5. Check where the drain piping flows into the floor drain. If water does not flow out, the unit is not properly draining. 6. Turn on the ON/OFF switch ON. Limited Warranty 90-1558 WARRANTY REGISTRATION P.O. Box 1467 • Madison, WI 53701-1467 • Phone: 800/334-6011 • Fax: 608/257-4357 • 10009173 4.11 B2205270B Printed in U.S.A. © 2011 Aprilaire – A division of Research Products Corporation Your Research Products Corporation Aprilaire® Dehumidifier is expressly warranted for five (5) years from date of installation to be free from defects in materials or workmanship. Research Products Corporation’s exclusive obligation under this warranty shall be to supply, without charge, a replacement for any component which is found to be defective within such five (5) year period and which is returned not later than thirty (30) days after said five (5) year period by you to either your original supplier or to Research Products Corporation, Madison, Wisconsin 53701, together with the model number and installation date of the dehumidifier. THIS WARRAN...

Dieses Handbuch ist für folgende Modelle:
Entfeuchter - 1750A (597.09 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien