DESCRIPTION PART NO. Q'TY PER SET REMARKSDH4010B DH5010B 1 POWER CORD ASSEMBLY 6411A20001Q 1 S, A 2 SWITCH, ROTARY 6600A20001A 1 S 3 MOTOR ASSEMBLY SINGLE 4681A20040A 1 S 4 CAPACITOR 0CZZA20001Q 1 S 5 COMPRESSOR (ROTARY) 2520UABC2FA 5416AR2179J 1 S 6 O.L.P. 6750U-L039A 1 S 7 LAMP, NEON 6912A30001F 1 S 8 THERMOSTAT 2H01127K 2H01127J 1 S 9 HUMIDISTAT 5216A20001A 1 S, A 10 SWITCH ASSEMBLY, MICRO 6600A30003C 1 S . S: SERVICE PARTS A: ALTERNATE PARTS N: NOT SERVICE PARTS —9— 3.1 MECHANICAL PARTS 3.1.1 BUCKET AND AIR FILTER 1. Disconnect the power supply. 2. Turn the Humidity Control off. 3. Remove the bucket. (See Figure 5) 4. Flex the filter at the lower right corner and take it off. (See Figure 5) 3.1.2 FRONT GRILLE 1. Remove 2 screws which fasten the front grille. 2. By pushing the both sides of front grille, pull the front grille forward and upward. (See Figure 6) 3.1.3. CABINET AND CONTROL BOX 1. Remove the Bucket, the Air filter and Front grille according to the procedure above. 2. Remove 3 screws that fasten Control box. (See Figure 7) 3. Remove 9 screws on all sides of the cabinet. 4. Lift the Cabinet from the base.(See Figure 8) 5. Remove a screw fasten the earth wire on the front of control box. 6. Unhook control box from two hooks on the shroud. (See Figure 8) —10— 3. DISASSEMBLY INSTRUCTIONS 1 2 Push Push Figure 5 Figure 6 Figure 7 Figure 8 3.2 CONTROL PARTS 3.2.1 ROTARY SWITCH, HUMIDISAT AND NEON LAMP 1. Unfasten screws located in the bottom side of control box (see Figure 9) and fasten capacitor clamp. (DH5010B/DH4010B) And then unfold two sides of control box. (See Figure 9) 2. Disconnect housing and all leads of rotary switch, humidistat and neon lamp. 3. Remove 4 screws which fasten the rotary switch and humidistat. 4. Pull the neon lamp out. 3.2.2 CAPACITOR 1. Remove each screw that fastens capacitor after control box is stretched upper wand.(See Fig. 9) 2. Disconnect all leads of capacitor then remove them from control box. 3.2.3 DEFROST CONTROL (Some Models) 1. Disconnect all leads of the defrost control in the Control Box. 2. Remove the defrost control from the suction tube. (See Figure 10) 3.2.4 THERMOSTAT CONTROL(Some Models) 1. Disconnect all leads of the thermostat on the control box. 2. Remove the capacitor in the control box.(some models) 3. Remove two screws that fasten the thermostat from the control box. (See figure 11) 3.2.5 MICRO SWITCH ASSY 1. Disconnect the housing with three leads connected in the Micro switch. 2. Turn the nut left and take off the micro switch from the barrier. (See Figure 12) 3.2.6 POWER CORD ASSY 1. After the control box opens, remove a screw that fastens the earth wire of the Power cord. 2. Disconnect housing and all leads of power cord then remove it from the unit. (See Figure 13) —11— DH5010B DH3010B DH4010B Defrost control Figure 9 Figure 10 Figure 12 Figure 11 Figure 13 3.2.7 FAN AND MOTOR 1. Turn the nut left and full out the Fan by hands carefully. 2. Remove 2 screws that fasten Heat Exchange. 3. Lift the H/E and open the H/E around 45 degree clockwise carefully. (See Figure 14) 4. Unfasten 3 screws that secure the Motor and earth wire. (See Figure 15) 5. Remove the Motor. 3.2.8 SHROUD AND BARRIER 1. Discharge the refrigerant by using a refrigerant Recovery System. 2. After purging the unit completely, unbrace the Discharge and the Suction tube connected compressor carefully. 3. Remove 2 screws that fasten the H/E. 4. Unfasten 3 screws that secure the shroud on back and sides and upward the shroud from Barrier. 5. Unfasten 2 screws that secure the Barrier to base pan. 6. Pull the Barrier backward then take it up from the base. —12— Figure 14 Figure 15 Figure 16 —13— 3.3 REFRIGERATING CYCLE 3.3.1 CONDENSER, EVAPORATOR AND CAPILLARY TUBE(HEAT EXCHANGE ASSEMBLY) 1. Remove the insulation on the H/E assembly 2. Pierce the pinch-off tube to discharge the refrigerant, using a FREONTM recovery system. 3. After discharging the refrigerant completely, remove 2 screws between the shroud and H/E. (See Figure 17) 4. Lift the H/E and open the H/E around 45 degree clockwise carefully. 5. Unbrace two interconnecting tubes of the evaporator and condenser carefully. 6. Remove the H/E assembly from the shroud. (See Figure 18) 7. Unbrace the capillary tube at the connections of each condenser and evaporator. (See Figure 19) 8. Remove 4 screws between condenser and evaporator. (See Figure 19) Figure 17 Figure 18 Figure 19 3.3.2 P.T.C. OR OVERLOAD PROTECTOR (O.L.P.) FOR RECIPROCATING COMPRESSOR 1. Remove the cabinet. (Refer to section 3.1.3) 2. Remove a screw or a nut which fastens the terminal cover 3. Disconnect the lead wire from the overload protector or P.T.C. assembly. 4. Remove the overload protector(O.L.P) or P.T.C. assembly. (See Figure 20) Using Recipro Compressor model Figure 20 3.3.3 ROTARY COMPRESSOR 1. Remove the cabinet. (Refer to section 3.1.3) 2. Discharge the refrigerant by using a refrigerant Recovery System. 3. After purging the unit completely, unbrace...

Dieses Handbuch ist für folgende Modelle:
Entfeuchter - DH3010B (1.35 mb)
Entfeuchter - DHA3012DL (1.35 mb)
Entfeuchter - DHA5012DL (1.35 mb)
Entfeuchter - DH5010B (1.35 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien