Hersteller: Amcor
Dateigröße: 1.28 mb
Dateiname: 3f0ffeb0-2def-4bb6-8df9-82007c181fd0.pdf
|
Anleitung Zusammenfassung
It must be operated in an enclosed area to be most effective. Close all doors, windows, and other outside openings to the room. 5. The appliance must not be modified in any way, as any modifications may be extremely dangerous. 6. Do not operate any appliance with a damaged cord or plug or after the appliance malfunctions, or has been damaged in any manner. Return appliance to the nearest authorized service facility for examination, repair or adjustment. 7. The use of accessory attachments is not recommended by the appliance manufacturer. It may cause injuries. 8. Do not use outdoors. 9. For your safety and protection, this dehumidifier is equipped with a three-prong grounding plug on the power cord. Do not, under any circumstances, cut or remove the round grounding prong from the plug. 10. Your dehumidifier must plug directly into a properly grounded and polarized three-prong outlet. If the wall outlet will not accept a three prong plug, or if you are not sure the outlet is adequately grounded or protected by a time delay (use or circuit breaker, have a qualified electrician install the proper outlet. Do not use an extension cord or an adapter plug. I I. Never unplug the dehumidifier by pulling on the power cord. Always grip the plug firmly and pull straight out from the outlet. Do not pinch, bend, or knot the power cord. 12. Always remove the plug from the socket before performing cleaning or maintenance operations and when not in use. 13. Do not place heavy or hot objects on the top of the appliance. 14. Clean the air filter every two weeks. 15. The appliance must always remain upright or laid on one side during transportation. Remember to drain the tank before transporting the appliance. I Specifications Model Number AD 400E Power Supply 120V / 60Hz / 1 Phase Power Consumption 446W / 3.92A Humidity Removal Capacity 43.5 pints / Day Refrigerant R-22 / 1 1.8 oz. Weight 46.3 lbs. Dimensions 16"W x 28"D x I0"H 2 Maintenance Always unplug the unit from the wall outlet before beginning cleaning. The unit is equipped with a washable filter. Follow the instructions below to remove and clean it. How to Remove Filter Take out the air filter by pressing the top of the air inlet grill (as shown in fig. I). Pull out the grill (fig.2) and extract the filter (fig.3). Cleaning the Filter • Wash filter in warm water. • Shake out excess water, lay flat, away from heat, until thoroughly dry. • Do not use hot water, solvents, detergent, or abrasive, material to clean filter. This may damage the element. • Clean filter every two weeks. To clean the outside of unit, use moist cloth. Avoid detergent and abrasive wipes. T3 ws fig-2 fig.3 7 Special Features 1. Automatic Dehumidification After setting the desired humidity, the unit will maintain the desired humidity automatically. 2. Continuous Drainage In order to remove excessive moisture from the air, with a minimum amount of attention, the humidifier is equipped with a pump to continually discharge condensed water. The continuous drainage point is high at the back of the unit, making it easy to reach and convenient to attach the supplied drainage tube. Water can be collected in a large container, or pumped to the outside. 3. Air Filter The dehumidifier features a cartridge type washable air filter. To access it press the top of the front grill. Once cleaned, again press the front grill back into position to lock the filter in place. IMPORTANT The operational temperature range for this unit is 41 °F to 95°F. This dehumidifier should not be used at temperatures below 41 °F. Running the unit above the temperature of 95°F will cause the compressor to stop as its over heat protector becomes activated. 4 Operation Operation instruction 1. POWER KEY Press to turn unit “ON” or “OFF”. 2. FAN SPEED Press to select fan speed “HI” or “LOW”. 3. TIMER a. Press the “TIMER” key to set the time desired (I -24 hour). b. Once the set time has come to an end, the unit will turn off automatically. c. Pressing the “POWER” key before the set time has been reached, the set time will be canceled when the unit turns off. 4. HUMIDITY SETTING Press to select the Humidity desired (RH 80% / 70 % / 60 % / 50 % / or CONTINOUS). When the room humidity is less than the selected humidity, the unitwill turn off automatically. The unit will turn on automatically when the room humidity is higher than the selected humidity. Actual Humidity and Indicated Humidity may vary by 5% (+ or -). 5. ALARM INDICATOR If this indicator illuminates, it means the water pump can not drain the water from the tank. Check to see that the drain hose is not blocked or bent, restricting the water flow. 6. DEFROST Periodically the defrost light will come on to indicate that the ice that forms as part of the process at low room temperatures is being melted off the cold internal coil. It should go off once the coil is sufficiently frost free to continue effective deh...