Login:
Stimmen - 3, Durchschnittliche Bewertung: 4 ( )

Anleitung Crane, modell EE-4109

Hersteller: Crane
Dateigröße: 278.52 kb
Dateiname: crane-ee-4109.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


POLARIZED PLUG This appliance has a polarized plug (one blade is wider than the other). As a safety feature to reduce the risk of electrical shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature. SAFETY WARNING Although your appliance is easy to operate, for your safety, the below warnings must be followed: 1. Do not place the appliance near a heat source. 2. Never leave the appliance unattended while connected to the electrical outlet. 3. To avoid any accidents, never cover mist vent when the appliance is in operation. 4. Use the appliance on a stable surface away from water. 5. Do not unplug from the wall socket by pulling on the supply cord. 6. The appliance must be unplugged: A. Before either filling or emptying B. Before any cleaning or maintenance C. After use D. If it appears to be faulty THIS PRODUCT IS INTENDED FOR HOUSEHOLD USE ONLY. LIST OF MAIN PARTS PARTS DESCRIPTION Fig. 1 (Central Body) 1. Night Light Switch 2. On/Off Switch/Regulator Control Knob 3. Power Cord 4. Central Body with water basin 5. Humidity Output Indication 6. Red/Green Power Light 3 6 5 1 2 4 6 Fig. 1 Fig. 2 (Top of Water Tank) 7. Vapor Outlet Channel 8. Water Tank Handle 87 Fig. 2 Fig. 3 (Water Basin) 9. Nebulizer 10. Vaporization Chamber 11. Fan Vent 12. Valve Opener 13. Water Level Sensor 13 9 10 11 12 Fig. 3 Fig. 4 (Bottom of Water Tank) 14. Water Tank Valve 15. Water Tank Cap 16. Vapor Outlet channel 14 15 16 Fig. 4 Fig. 5 (Water Tank Lid) 17. Water Tank Lid 18. Vapor Output Slots 17 18 Fig. 5 TECHNICAL SPECIFICATIONS: Rating Voltage 120V Frequency 60Hz Power 45W Water Tank Capacity Approx. 1.0 Gallon / 3.78 Liter Output Per 24 Hours Approx. 2.1 Gallon / 8 Liter Run Time Per Tank Min. 11 Hours Humidifying Capacity Up to 500 sq.ft. / 46 m2 Noise < 36.5 (dB) A CONTENTS OF PACKAGING a. Instruction Manual b. Central Humidifier Body c. Water Tank d. Water Tank Lid with Vapor Output Slots If any of the above items are missing, please contact our service department at 1-888- 599-0992 (for replacement. Business hours Mon-Fri 9:00am - 4:00pm CT OPERATION AND USE BEFORE EACH USE CHECK HUMIDIFIER PLACEMENT - Place the Humidifier on an elevated non-metallic waterproof surface for best performance. This is to help disperse the mist in the air, and prevent it from being knocked or tipped over. CHECK WATER LEVEL SENSOR - Make sure that the water level sensor is secured properly. Refer to “cleaning and maintaining water level sensor” on page 9 for instructions on how to clean water level sensor. CHECK FAN VENT - This fan vent is located on the bottom of the humidifier. The purpose of the fan vent is to blow the cool mist through the vapor outlet slots. It is important that this part is kept clean and free of obstructions. We recommend checking the fan vent before using this item (i.e. lint, paper) Do not place Humidifier on top of a towel, or a carpeted surface. The air vent on the bottom may become blocked, and overheat the humidifier. CAUTION: DO NOT operate the humidifier without water in the water tank. DO NOT plug in the cord with wet hands; electric shock could happen ASSEMBLY 1. Lift the water tank off the central body. 2. Turn over the water tank and unscrew the water tank cap at the bottom of the tank by turning it counterclockwise. (See Fig. 6) Fig. 6 3. Fill water tank with cold water; do not fill all the way to the rim. (See Fig. 7) Note: To avoid possible white dust due to hard water it is recommended to use distilled water. DO NOT use hot water. Use cool tap water. DO NOT add any medication or other additives to the water DO NOT pour water into Vapor Outlet Channel (Fig.2 on page 4) Fig. 7 4. Replace the water tank cap, aligning the threads on the tank with the threads on the cap, and turn it clockwise. (See Fig. 8) Fig. 8 5. Turn the tank over, holding it by the top handle, and place it on the central body, making sure it fits perfectly. Place the water tank cap with output slots on top of the water tank. (see Fig. 9) Fig. 9 6. Plug the power cord into a wall socket and turn on the unit. The On/Off switch is located at the turning knob (see figure 10). 7. The Power Light will turn on red. In a few seconds it will switch to green, indicating that enough water is in the water basin, and vapor will start emitting through the openings at the water tank lid. 8. Use the humidity output regulator control knob to adjust the intensity of the vapor output. Turning the knob clockwise will increase the moisture output, turning the knob counterclockwise will reduce the moisture output. (see Fig. 10) Fig. 10 9. When the humidifier runs out of water the power light will turn red, and the mist output will stop. This is a safety feature to prevent the humidifier from possibly over heating and damaging the nebulizer. This safety fe...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien