Anleitung Dri-Eaz, modell 2400 LG

Hersteller: Dri-Eaz
Dateigröße: 99.41 kb
Dateiname: 81978888-2ce7-4efe-b066-d3b1ad33f2b8.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


When the unit is first plugged in, the display cycles through three messages: DEHUMIDIFER OFF, TOTAL HOURS , and JOB HOURS. Press the ON-OFF key to turn the unit on. The display often reads CMPRSR DELAY 00, with the numeral counting down from a maximum of 60 seconds to 0. At that point the unit begins to operate and the display reads DEHUMIDIFIER ON. (The delay prevents damage from accidental power interruptions, where power to the compressor stops and then starts again when pressure in the system is still high.) PURGE. Push this key to run the purge before tipping the unit. This empties water from the pump reservoir to prevent leakage. If the unit has been operating, turn the power OFF but leave the cord plugged in for about 10 minutes while water drips from the coil; then press PURGE to remove residual water. The purge also runs automatically every six minutes during operation, and whenever the reservoir is full. While the purge is running, the display reads PUMP PURGING. DISPLAY. Press the DISPLAY key to stop the display at DEHUMIDIFER ON or OFF, TOTAL HOURS, or JOB HOURS, when it is cycling. Press again to make the dis play cycle again. CLEAR. To clear the JOB HOURS reading, first press the DISPLAY key to make the display read JOB HRS steadily. Then press the CLEAR key to re-set the numerals to 00000. NOTE: the TOTAL HOURS reading cannot be re-set. Defrost On The display will read DEFROST ON whenever the unit is in a defrost cycle. During normal operation, frost forming on the coils is detected by the temperature sensor, causing a defrost cycle to start. Dehumidification is suspended as hot gas flows through the coils and melts the frost. At the end of the defrost cycle, the display returns to its normal condition. Changing Language Shown on Display The default language is English. To change to another language, follow these steps. (1) The unit must be unplugged from the power outlet. Hold down the DISPLAY key while plugging the unit in. The display now reads "ENGLISH." (2) Press the DISPLAY key or the CLEAR key to adjust the reading to FRANCAIS, DEUTSCH, or ESPANOL. (3) Then unplug the unit from the power outlet, which sets the language. CAUTION: While in the change-language mode, pressing other keys can change operating parameters of the unit. Do NOT press other keys or change parameters, except when following guidelines from the Dri-Eaz Service Department. Error Messages In case of certain problems, the display may show the error message "GET SERVICE," followed by "ER01" or another numeral. Follow these steps: 1. First, unplug the unit and then plug it back in. This may reset the electronics. 2. If that does not fix the problem, try the solution if one is listed in the table below. 3. If that does not fix the problem, contact the Dri-Eaz Service Department ( contact information above). ER 1-2-3-5-6 Problem with the electronic control panel. Contact Service. ER4 Problem with temperature sensor or cable. ER8 Problem with a touchpad key. Press and release each key several times. ER9 Check for obstructions in pump or drain hose, or that pump wiring is correct. ELECTRICAL CONNECTIONS DrizAir Dehumidifiers are designed to operate on a 115V/60 Hz electrical connection. Make sure that the electrical outlet is grounded and that all safety precautions are taken. MAINTENANCE Always turn off the power before performing maintenance procedures. All the service procedures below are to be executed with the unit unplugged. Perform before each use or as needed. INSPECT ELECTRICAL SYSTEM: Inspect the electrical cord for damage at regular intervals. Periodically, remove the housing and inspect internal wiring for bare wires, insecure fasteners, and discoloration. Remove and repair any damaged wiring as needed. Failure to do so may lead to electrical shock or a fire hazard. Copyright 2000, 2002 Dri-Eaz Products, Inc. 2 PUMP TUBE: Make sure the pump tube is completely unwrapped and not kinked. Failure to do so can cause water to back up in the pump and leak out. The control panel may signal this problem by displaying .ER9.. KEEP OUT DUST. Keep dust from drywall, demolition, and other sources out of the coils. Failure to do so can cause the unit to overheat, leading to compressor failure or other problems. Do not run the unit during sanding, painting or other operations producing airborne particulate. When dust is present, use the optional pleated paper filter to keep more dust out of the unit; also, inspect and clean the coils as required. USE A CLEAN FILTER. Keep a clean filter in the unit at all times to keep out dust. When using a foam filter, clean with a vacuum, or wash with water and mild detergent and allow it to dry. When using paper filters, discard the filter when visibly dirty and insert a clean one. SHINE EXTERIOR: Use a sponge and mild detergent for regular cleaning. Do not pour or run water onto the unit or allow water to soak the touchpad control. Bring back the original shine with a vinyl cleaner-polish. P...

Dieses Handbuch ist für folgende Modelle:
Entfeuchter - 2000 LG (99.41 kb)
Entfeuchter - 1200 (99.41 kb)
Entfeuchter - 80 (99.41 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien