Anleitung Zusammenfassung
Loud noise and/ Is the unit on a level surface? Move the unit to a level surface. CLEANING THE BUCKET or vibration during Pull the bucket out. Lift off bucket cover. operation. (Fig.1) Clean the inside d bucket every week Sounds. Sounds like flowing water This is the normal sound of the using mild detergent in order to block buildup during and after operation. refrigerant flowing through the coils. d mold and bacteria. (Fig.2) It makes a pinging sound. Normal sound of expansion and Fig.3 Fig.4 After cleaning, replace the bucket cover and slide the bucket into the unit. (Fig.3) contraction changes. caused by temperature CLEANING SIDE GRILLS AND AIR FILTERS 1. Snap open the bottom tab of filter located below the of side grill. (Fig.l) Grills are located on both sides of unit. Check the float switch to make sure it is not obstructed. Proper position of the bucket and the float switch is required for the dehumidifier to turn on. Dehumidification function is inefficient Are the filters and grills dirty? Is indoor temperature under 65°F? Clean the SIDE GRILL and AIR FILTER. Although the unit will dehumidify at temperatures below 65 degrees, there is a potential for frost to develop which may inhibit the unit's efficiency 2. Pull the filter down and away from unit until it is all the way out. (Fig.2) Unit is discharging warm air. Normal: Compressor and electric motor discharge nominal heat. Note: The filter is extremely flexible. This action will not damage the filter. Water does not through hose. drain Check the DRAIN CONNECTOR. Is it installed correctly? Check the drain hose for Re-install drain hose according to this manual. Flatten the hose or remove block3. Wash with mild detergent. Rinse thoroughly. Fig .2 kinks or obstructions. age. Air dry away from direct sunlight. Float Switch Is PUMP light on? Turn on the pump. 4. Using both hands, insert the top edge d the filter into the slot below the side grill and slide into place. (Fig.3) Snap the Waterdoes notdrain through garden hose. Check the DRAIN NECTOR making installed securely. CON- sure it is Re-install it according to this manual. bottom tab into the closed position. Check the garden hose for Flatten the hose or remove block5. SIDE GRILLS can be cleaned using a vacuum cleaner or a soft brush to remove Fig.3 tangles or folds. age. dust. (Fig.4) Water does not drain through pump drain Check the connecting for tangles or folds. hose Re-install drain this manual. hose according to 6. SIDE GRILLS can be cleaned using a vacuum cleaner or a soft brush to hose. Flatten the hose or remove blockage. remove dust. CHECK YOUR FILTERS Does pump display light Turn on the pump. PERIODICALLY TO INSURE PROPER appear? OPERATION. (Fig.4) Error Code Error Type Possible Causes Corrective Actions E0 E 1 Temperature Sensor Defrost 1. Sudden changein the surrounding 1. Unplug the dehumidifier. 2. Check the surrounding area for possible reasons for sudden temperature changes. 3. Wait 30 minutes before plugging the Sensor temperature. dehumidifier back in and resuming normal E2 Humidity i2. Faulty sensor. operation. 4. If the "Error" is still indicated, please Sensor contact your nearest service center. E3 Pump Drain 1. Improperbucket 1. Unplug the dehumidifier. 2. Remove the bucket. installation. 3. Check to make sure that there is nothing 2. Blockage to drain hose blocking the connection pump or the bucket. at the base of the system. 4. Reinstall the bucket, taking care that it is 3. Back flow of installed properly. water through 5. Check to make sure that the pump drain pump drainhose. hose is not crimped or blocked. 6. Check to make sure that the pump drain 4. Improper pump hose is not both under water and sitting at drain hose installation. a height above the dehumidifier -this can cause a "back flow" of water from the hose 5. Faulty drain to the dehumidifier. pump. 7. Remove and reinstall the pump drain hose, taking care that the pump drain hose is installed properly. 8. Plug the dehumidifier in and restart 9. If the "E3" error is still indicated, please contact your nearest service center. Classification Spec Remark Model 251.90701 Power Supply AC 115V/60(Hz) Moisture Removal 70 Pint(33.11iters) 24-Hour Period Control Type Electronic Refrigerant R410A/11.29 oz. 320g Humidity Humidity Setting: 35%-70% 5% Increments Display Display Range: 20%-90% 1% Increments. Current Humidity. Temperature Display Range: Lo, 36-99°F, Hi 1° F Increments. Current Temp. Display Display Range: Lo, 2-37°C, Hi 1° C Increments. Current Temp. Timed Shut-off Setting Range: 1Hr-12Hr 1 Hour Increments Fan Motor Speed 3 Speeds Auto/High/Low Dimensions 15.74x25.59x13.6 in 400x650x346mm Net Weight 49 lbs 22.3Kg Operating Temp. 36°F-99°F Drain Pump 12V DC Pump Drain Hose .25 in x 18 ft 6.35x5,486mm 10 The remote monitoring station is a receiver with a receiving range of only 330 feet in open air with no obstructions. Actual receiving range will vary depending on what is in the path of the signal transmitte...