|
Anleitung Zusammenfassung
Notes: • MC coils available with a factory installed horizontal drain pan option (H). COOLING CAPACITY - COIL ONLY* Model Rated CFM Entering Air °F (Wet Bulb) MBH @ EVAPORATOR TEMPERATURE AND CORRESPONDING PRESSURE °F / PSIG 35/61.5 40/68.5 45/76.0 50/84.0 HC18A 600 72 26.4 24.0 21.5 18.6 67 24.3 22.0 19.4 16.8 62 20.0 17.7 15.3 12.9 57 16.1 14.0 11.8 9.2 HC30A 1000 72 42.7 38.9 34.7 30.6 67 34.3 30.3 26.5 22.5 62 26.7 22.5 24.5 19.8 57 22.9 21.2 19.6 18.3 HC36B 1200 72 73.4 63.1 52.5 41.5 67 58.8 49.3 40.2 30.7 62 45.8 36.4 29.7 24.8 57 39.3 34.4 28.1 23.2 HC42C 1400 72 84.9 73.0 60.1 48.1 67 68.0 58.9 46.5 35.6 62 53.1 42.2 34.4 28.8 57 45.5 40.0 32.0 26.7 HC60C 1800 72 112.8 95.0 77.0 58.4 67 90.3 74.5 58.8 43.1 62 70.3 55.1 43.4 34.9 57 60.4 52.1 40.4 31.9 * See Condensing Unit or Heat Pump Technical Guide for Total Cooling Capacity and Sensible Capacity. 4 Unitary Products Group 258931-BTG-A-0606 COOLING CAPACITY - COIL ONLY* Model Coil Rated CFM Entering Air °F (Wet Bulb) MBH@ Evaporator Temperature and Corresponding Pressure “F / PSIG Зб / 61.б 40 / 68.б 4б / 76.0 б0 / S4.0 uncased upflow 72 23.3 21.3 19.0 17.5 ÜC1SA б0 б7 21.5 19.5 17.3 14.9 ÜC1SB б2 17.7 15.6 13.5 11.4 57 14.4 12.4 10.4 S.0 72 27.4 25.0 22.3 19.4 ÜC24A S00 б7 25.3 22.9 20.3 17.5 UC24B б2 20.S 1S.4 15.9 13.4 57 16.9 14.6 12.2 9.4 72 35.2 32.0 2S.6 24.S ÜC30A 1000 б7 32.4 2S.6 25.3 21.9 ÜC30B б2 2б.б 23.6 21.5 1S.7 57 25.2 22.7 20.2 17.6 72 46.S 42.7 37.9 33.0 UC36A 1150 б7 43.1 39.2 34.9 30.4 б2 35.3 32.1 2S.6 24.9 57 33.3 26.9 2б.9 23.4 72 49.3 44.9 39.9 34.7 UC36B 1200 б7 45.4 41.3 3б.7 32.0 UC36C б2 37.2 33.S 30.1 2б.2 57 35.0 2S.3 2S.3 24.б 72 S6.7 73.0 59.2 44.9 UC42B 1400 б7 б9.4 57.2 45.2 33.1 UC42C б2 54.0 42.3 33.4 26.S 57 46.4 40.0 33.4 26.S 72 62.4 56.S 50.5 44.4 UC4SC 1600 б7 57.4 53.2 4б.5 40.5 UC4SD б2 47.1 42.S 3S.1 33.2 57 44.3 40.3 35.S 31.2 72 95.4 S2.1 6S.4 54.0 UC60C 1S00 б7 7б.4 64.1 52.2 39.9 UC60D б2 59.б 47.4 3S.6 32.4 57 51.2 44.S 3S.6 32.4 * See Condensing Unit or Heat Pump Technical Guide for Total Cooling Capacity and Sensible Capacity. APPLICATION FACTOR-RATED CFM VS. ACTUAL CFM % OF RATED AIR FLOW S0% 90% RATED CFM 110% 120% CAPACITY FACTOR 0.96 0.9S 1.00 1.02 1.03 NOTE:Do not exceed minimum/maximum CFM limits shown under Air Flow Data. APPLICATION LIMITATIONS These units must be installed in accordance with all national and local safety codes. Air flow must be within the minimum and maximum limits approved for electric heat, evaporator coils and outdoor units. Entering Air Temperature Limits Wet Bulb Temp. °F Dry Bulb Temp. °F Min. Max. Min. Max. 57 72 65 95 Unitary Products Group 5 258931-BT G-A-0606 STATIC PRESSURE VS. AIRFLOW (BASED ON UPFLOW CASED "A" TYPE Model Airflow Wet Coil FC18A PC18A 600 0.16 800 0.23 1000 0.30 FC18B PC18B 600 0.14 800 0.20 1000 0.26 FC24A PC24A 600 0.15 800 0.21 1000 0.27 FC24B PC24B 600 0.13 800 0.18 1000 0.23 FC30A PC30A 800 0.21 1000 0.27 1200 0.33 FC30B PC30B 800 0.18 1000 0.23 1200 0.29 FC35B PC35B 800 0.16 1000 0.22 1200 0.29 FC35C PC35C 800 0.14 1000 0.20 1200 0.27 FC36A PC36A 1000 0.24 1200 0.32 1400 0.40 FC36B PC36B 1000 0.15 1200 0.22 1400 0.28 FC36C PC36C 1000 0.10 1200 0.15 1400 0.20 1200 0.21 FC42B 1400 0.28 PC42B 1600 0.34 1800 0.40 1200 0.14 FC42C 1400 0.19 PC42C 1600 0.24 1800 0.28 1600 0.29 FC48C 1800 0.35 PC48C 2000 0.40 2200 0.46 1600 0.25 FC48D 1800 0.30 PC48D 2000 0.35 2200 0.40 1600 0.28 FC60C 1800 0.33 PC60C 2000 0.38 2200 0.43 1600 0.21 FC60D 1800 0.27 PC60D 2000 0.32 2200 0.38 WET COIL) HORIZONTAL - DUCT TYPE Model Airflow Wet Coil HD24A 600 0.02 800 0.09 1000 0.19 HD36B 1000 0.19 1200 0.28 1400 0.38 HD48C 1200 0.14 1400 0.19 1600 0.25 1800 0.32 HD60D 1600 0.16 1800 0.20 2000 0.25 2200 0.30 HORIZONTAL CASED Model Airflow Wet Coil HC18A 600 0.07 800 0.12 1000 0.19 HC30A 800 0.21 900 0.25 1150 0.30 1200 0.31 HC36B 1000 0.20 1100 0.24 1200 0.27 1300 0.30 HC42C 1400 0.25 1500 0.28 1550 0.30 1600 0.33 HC60C 1700 0.25 1800 0.28 1850 0.30 1900 0.31 2000 0.34 6 Unitary Products Group 258931-BTG-A-0606 CASED "A" TYPE MULTI-POSITION Model Airflow Wet Coil MC18A 600 0.22 800 0.29 1000 0.36 MC18B 600 0.20 800 0.26 1000 0.32 MC24A 600 0.21 800 0.27 1000 0.33 MC24B 600 0.19 800 0.24 1000 0.29 MC30A 600 0.21 800 0.27 1000 0.33 MC30B 600 0.19 800 0.24 1000 0.29 MC35B 600 0.22 800 0.26 1000 0.34 MC35C 600 0.20 800 0.24 1000 0.32 MC36A 800 0.22 1000 0.30 1200 0.38 MC36B 800 0.15 1000 0.21 1200 0.28 MC36C 1000 0.16 1200 0.21 1400 0.26 MC42B 1200 0.27 1400 0.34 1600 0.40 MC42C 1200 0.20 1400 0.25 1600 0.30 1800 0.34 MC48C 1200 0.24 1400 0.30 1600 0.35 1800 0.41 MC48D ...
Dieses Handbuch ist für folgende Modelle:Pumps - HC (622.08 kb)
Pumps - HD (622.08 kb)
Pumps - MC (622.08 kb)
Pumps - PC (622.08 kb)