Login:
Stimmen - 1, Durchschnittliche Bewertung: 4 ( )

Anleitung AquaPRO, modell GPH550PRO

Hersteller: AquaPRO
Dateigröße: 316.74 kb
Dateiname: e985fa06-4e00-42c2-b509-798fac3608f3.pdf
Unterrichtssprache:enes
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference. Gas Powered Water Pump QUALITYASSURANCEPROGRAM Need Assistance? Call Us First! 1-877-278-2797 Description The Aqua Pro pumps are general use centrifugal water pumps. Safety Guidelines This manual contains information that is very important to know and understand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols. ! DANGER Danger indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Warning indicates ! WARNING a potentially hazardous situation which, if not avoided, could result in death or serious injury. Caution indicates a ! CAUTION potentially hazardous situation which, if not avoided, may result in minor or moderate injury. Notice indicates NOTICE important information, that if not followed, may cause damage to equipment. General Safety Information 1. Know the pump application, limitations, and potential hazards. Read these rules and the instructions carefully. Failure to follow them could cause serious bodily injury and/or property damage. ! DANGER Never run engine in an enclosed area. Exhaust gases contain deadly poisonous carbon monoxide, which has no odor or taste. ! WARNING Do not use to pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc. Do not use in flammable and/or explosive atmospheres. Pump should only be used with liquids compatible with pump component materials. Failure to follow this warning can result in personal injury and/or property damage. 2. Observe all safety precautions for the handling of the fuel. ! WARNING Do not refuel a hot engine. Fuel spilled on a hot engine could result in a fire or explosion. Do not refuel a running engine. 3. Pump should be located and should rest on a level solid foundation. Do not suspend pump by means of the discharge pipe. Be sure pump is on NOTICE secure footing so it doesn’t fall over. 4. Do not use torches or apply excessive heat, fire or flames to this pump as an explosion may result. 5. Before working on the unit, insulate the wire from the spark plug, disconnect the spark plug wire and mount it on the grounding clip. Complete pump NOTICE and piping system MUST be protected against below freezing temperature. Failure to do so could cause serious damage and voids the warranty. 6. Do not run pump dry. Water is required to lubricate the shaft seal. 7. Pumping chemicals or corrosive liquids with this pump may shorten the life of the pump and may be hazardous to the operator. 8. Personal Safety: a. Wear safety glasses at all times when working with pumps. b. Keep work area clean, uncluttered and properly lighted; replace all unused tools and equipment. c. Keep visitors at a safe distance from the work area. d. Make workshop child-proof with padlocks, master switches, and by removing starter keys. 9. Always use a suction strainer with this pump to filter large material. Installation This pump is designed to be self- priming when installed and operated as specified below. 1. The pump should be placed as close as possible to the liquid being pumped. A pump with 20 foot suction lift will not remove water as quickly as a pump with 5 foot suction lift (Figure 1). Figure 1 20 Ft. Suction Lift 5 Ft. Suction Lift 2. Suction hose and fitting must be airtight. REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping. 322600-013 03/06 Operating Instructions and Replacement Parts List Installation (Continued) An air leak in the NOTICE suction line may prevent priming of the pump. Use of thread sealant is recommended. Suction lines must be reinforced hose or rigid pipe. Non-reinforced hose will collapse due to the suction created by the pump and prevent pump from operating. 3. A check valve must be used in the suction line to maintain the self- priming capability. If no check valve is used the pump will need to be primed at the start of each operation. For best operation, the check valve should be installed at the intake of the suction line.(Figure 2). Figure 2 4. A suction strainer is required to filter abrasive material. 5. The discharge hose and fitting should be leak-tight. A leak in the discharge hose will allow water to spray around the work site, making the site hazardous. 6. Keep all pipes and hose lines as short and straight as possible. Long lengths and curves in the pipes and hose lines will reduce the pressure the pump develops. 7. Fill the engine crankcase with oil. Refer to the engine operating manual for the specific grade of oil and amount required. 8. Fill the engine fuel tank with gasoline. Refer to the engine operating manual for specific gasoline type that is most efficient for this engine. 9. Add water to the priming port...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien