Anleitung Zusammenfassung


evaporator above condenser (See Longline Guide for more information.) • Low ambient (down to -20 _F) with accessory kit Warranty Single Phase • 5 year limited compressor warranty • 5 year limited parts warranty Three Phase • 5 year limited compressor warranty • 1 year limited parts warranty 213R MODEL NUMBER NOMENCLATURE 1 2 3 N N N 2 1 3 Prod- uct Family Tier SEER 1 = 2 = HP Legacy 3 = 13 SEER RNC 4 5 6 A A/N N R N A Major Series Voltage Variations N = 208/230-1 A = Standard R = R-22 P=208/230 G = Dense Coil -3 Guard E=460/3 7 8 9 10 N N N A/N 0 3 6 0 Cooling Capacity Open 0=Not Defined 11 12 14 A/N N A 0 0 0 Open Open Series 0=Not 0=Not A = Defined Defined Original ENERGYSTAR PARTNER As an Energy Star® Partner, Bryant Heating &Cooling Systems has determined that this product meets the ENERGY STAR® guidelines for energy efficiency. Refer to the combination ratings in Product Data for system combinations that meet Energy Star guidelines. STANDARD FEATURES Feature 18 24 30 36 42 48 60 13 SEER X X X X X X X Scroll Compressor X X X X X X X Wire Coil Guard X X X X X X X Field Installed Filter Drier X X X X X X X Front Seating Service Valves X X X X X X X Internal Pressure Relief Valve X X X X X X X Internal Thermal Overload X X X X X X X Long Line capability X X X X X X X Low Ambient capability with Kit X X X X X X X Loss of Charge Pressure Switch X X X X X X X 2 PHYSICAL DATA UNIT SIZE - SERIES 018-A 024-A 030-A 036-A 042-A 048-A 060-A Operating Weight (lb) 159 160 208 211 233 269 295 Shipping Weight (lb) 184 185 240 242 262 300 327 Compressor Type Scroll REFRIGERANT Freon® (R-22) Control TXV (R- 22 Hard Shutoff) Charge (lb) 5.5 6 7.5 8 10 14 15.5 COND FAN Propeller Type, Direct Drive Air Discharge Vertical Air Qty. (CFM) 2233 2614 2614 3334 3334 4046 4046 Motor HP 1/12 1/10 1/10 1/8 1/8 1/5 1/5 Motor RPM 800 1100 1100 800 800 800 800 COND COIL Face Area (Sq. ft.) 15.09 15.09 25.87 22.63 17.6 22.63 25.15 Fins per In. 20 20 20 20 20 20 20 Rows 1 1 1 1 2 2 2 Circuits 5 6 6 6 7 8 9 VALVE CONNECT. (In. ID) Vapor 5/8” 5/8” 3/4” 3/4” 7/8” 7/8” 7/8” Liquid 3/8” REFRIGERANT TUBES* (In. OD) Vapor (0-80 Ft. Tube Length) 5/8” 5/8” 3/4” 3/4” 7/8” 7/8” 1-1/8” Liquid (0-80 Ft. Tube Length) 3/8” * For tubing sets between 80 and 200 ft. horizontal or 20 ft. vertical differential, consult the Longline Guideline. Note: See unit Installation Instruction for proper installation. VAPOR LINE SIZING AND COOLING CAPACITY LOSS 1-STAGE HEAT PUMP APPLICATIONS LONG LINE APPLICATION: An application is considered ”Long line” when the total equivalent tubing length exceeds 80 ft. or when there is more than 20 Ft. vertical separation between indoor and outdoor units. These applications require additional accessories and system modifications for reliable system operation. The maximum allowable total equivalent length is 250 ft. The maximum vertical separation is 200 ft. when outdoor unit is above indoor unit, and 60 ft. when the outdoor unit is below the indoor unit. Refer to Accessory Usage Guideline below for required accessories. See Long -Line Application Guideline for required piping and system modifications. Also, refer to the table below for the acceptable vapor tube diameters based on the total length to minimize the cooling capacity loss. Acceptable Vapor Line Diameter OD (in.) Cooling Capacity Loss (%) Total Equivalent Line Length (ft.) Unit Nominal Size (Btuh) Standard Application Long Line Application Requires Accessories 25 50 80 80+ 100 125 150 175 200 225 250 18000 5/8 0 1 1 1 2 3 3 4 5 5 6 R-22 HP 3/4 0 0 0 0 0 1 1 1 1 2 2 24000 5/8 0 1 3 3 3 5 6 7 8 9 10 R-22 HP 3/4 0 0 0 0 1 1 1 2 2 3 3 30000 3/4 0 1 1 1 2 3 3 4 5 5 6 R-22 HP 7/8 0 0 0 0 1 1 1 2 2 2 3 36000 3/4 0 1 2 2 3 4 5 6 7 8 9 R-22 HP 7/8 0 0 1 1 1 2 2 3 3 4 4 42000 R-22 HP 7/8 0 1 1 1 2 2 3 4 4 5 5 48000 R-22 HP 7/8 0 1 2 2 2 3 4 5 5 6 7 60000 R-22 HP 7/8 1 2 3 3 4 5 7 8 9 10 11 1 1/8 0 0 1 1 1 1 2 2 2 3 3 Standard Length = 80 ft. or less total equivalent length Applications in this area are long line. Accessories are required as shown recommended on Long Line Application Guidelines Applications in this area may have height restrictions that limit allowable total equivalent length, when outdoor unit is below indoor unit See Long Line Application Guidelines 3 213R 213R ACCESSORY THERMOSTATS THERMOSTAT / SUBBASE PKG. DESCRIPTION TSTATBBPRH01 -B* Thermidistat™ Control — Non-Programmable/Programmable Thermostat with Humidity Control (For use in Dual Fuel, AC, HP and 2S applications. Includes Outdoor Air Temperature Sensor.) TSTATBBPHH01 -B* HybridHeat™ (Dual Fuel) Thermostat — Auto Changeover, 7-Day Programmable, °F/°C, Includes Outdoor Sensor (TSTATXXSEN01 -B) TSTATBBPHP01 -B Thermostat — Auto Changeover, 7-Day Programmable, °F/°C, 2-Stage Heat, 1 - Stage Cool TSTATBBNHP01 -C Therm...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien