Login:
Stimmen - 6, Durchschnittliche Bewertung: 4.2 ( )

Anleitung Campbell Hausfeld, modell FP2090

Hersteller: Campbell Hausfeld
Dateigröße: 1.26 mb
Dateiname: ecc95808-3b25-4880-9a2c-728d890506eb.pdf
Unterrichtssprache:enesfr
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Make sure the product is connected to an outlet having the same configuration as the plug. This product must be grounded. In the event of an electrical short circuit, grounding reduces risk of electrical shock by providing an escape wire for electric current. This product is equipped with a cord having a grounding wire with an appropriate grounding plug. Plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances. Figure 1 - Grounding Method Grounding Pin Grounded Outlet Improper use of grounding plug can result in a possible risk of electrical shock! Do not use a grounding adapter with this product! 2 FP2090, FP2091, FP2094 Series 3 2. If repair or replacement of cord or plug is necessary, do not connect grounding wire to either flat blade terminal. The wire with insulation having an external surface that is green (with or without yellow stripes) is the grounding wire. Never connect green (or green and yellow) wire to a live terminal. 3. Check with a qualified electrician or serviceman if grounding instructions are not completely understood, or if in doubt as to whether product is properly grounded. Do not modify plug provided; if it will not fit outlet, have proper outlet installed by a qualified electrician. Overheating, short circuiting and fire damage will result from inadequate wiring, etc. Operation Definition of Terms ON / OFF Switch ( I / O ) - Push switch to the ON ( I ) position to turn compressor on. Push switch to the OFF ( O ) position to turn compressor off. This switch should be in the OFF ( O ) position when connecting / disconnecting power cord from electrical outlet or when changing tools. Pressure Switch (located internally)- When the compressor is turned ON, this switch will shut compressor off automatically when tank pressure reaches maximum shut-off / cut-out pressure. If compressor remains on and air is depleted from tank, this switch will allow compressor to automatically restart at the restart / cut-in pressure. Regulator - The regulator controls the amount of air pressure released at the hose outlet. Turning the regulator knob clockwise (to the right) will increase air pressure at the outlet. Turning the knob counter-clockwise (to the left) will lower air pressure to the outlet. Turning knob fully counter-clockwise will shut off flow of air completely. Pressure Gauges - There are two gauges located next to the regulator. These gauges read air pressure in pounds per square inch (psi) The larger gauge shows pressure at the outlet. Make sure this gauge reads ZERO (by adjusting the regulator) BEFORE changing air tools or disconnecting hose from outlet. The small gauge shows pressure in the tank indicating compressor is building pressure properly. ASME Safety Valve - This valve automatically releases air if the tank pressure exceeds the preset maximum. Handle - Designed to move the compressor. Drain Valve - This valve is located on the bottom of the tank. Use this valve to drain moisture from the tank daily to reduce the risk of corrosion. Motor Reset - (not shown, located inside motor). Designed to keep the motor from overheating. The motor has an auto reset protector. To reset once the motor has cooled, turn the switch to the OFF position, then to the ON position. This compressor is equipped with an overload protector which will shut off motor if it becomes overloaded. If the overload protector is actuated, the motor must be allowed to cool down for approximately 30 minutes before it will reset. LUBRICATION This is an oilless product and DOES NOT require lubrication to operate. BEFORE FIRST STARTUP BREAK-IN PROCEDURE (Complete this procedure before using compressor for the first time. Once completed, it is not necessary to repeat.) 1. Turn regulator knob fully clockwise (to the right) to open air flow. 2. Do not attach a hose or any other fitting to the compressor. 3. Turn on/off switch to OFF position. 4. Plug in power cord. 5. Turn on/off switch to ON position. Allow compressor to run for 5 minutes. 6. Turn on/off switch to OFF position. ON/OFF Switch Drain Valve Figure 2 - Unit Identification Handle Pressure Gauges Safety Valve Air Outlet Regulator OFF Position Figure 3 ON Position Figure 4 Installation (Continued) Oilless Compressors Operation (Continued) 7. Unplug power cord. BEFORE EACH STARTUP OPERATING PROCEDURE 1. Turn switch to OFF ( O ) position and plug in power cord. 2. Turn regulator knob counterclockwise to close air flow. 3. Turn switch to ON ( I ) position. 4. Compressor will build to maximum pressure and shut off. 5. With hose attached to outlet of compressor, attach tire chuck or other tool to open end of hose. 6. Adjust regulator to proper pressure for tool or tire. Operate tool per instructions. As air is depleted from the tank by use of a tire chuck, tool, etc., the compressor will restart automatically at its preset “cut-in” pressure. When a tool is being used continuously, the compressor will cy...

Dieses Handbuch ist für folgende Modelle:
Pumps - FP2094 (1.26 mb)
Pumps - FP209000 (1.26 mb)
Pumps - FP2091 (1.26 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien