|
Anleitung Zusammenfassung
2. Turn regulator knob counterclockwise to close air flow. 3. Turn switch to ON ( I ) position. 4. Compressor will build to maximum pressure and shut off. 5. With hose attached to outlet of compressor, attach tire chuck or other tool to open end of hose. 3 Oilless Compressors Operation (Continued) 6. Adjust regulator to proper pressure for tool or tire. Operate tool per instructions. As air is depleted from the tank by use of a tire chuck, tool, etc., the compressor will restart automatically at its preset “cut-in” pressure. When a tool is being used continuously, the compressor will cycle on and off automatically. 7. Turn switch to OFF ( O ) position, unplug power cord and drain tank of air when finished using compressor. Maintenance Disconnect power source then release all pressure from the system before attempting to install, service, relocate or perform any maintenance. The compressor should be checked often for any visible problems and the following maintenance procedures should be performed each time the compressor is used. aSMe SaFety ValVe Do not remove or attempt to adjust the safety valve! Figure 5 Check the safety valve by performing the following steps: 1. Plug the compressor in and run until shut off pressure is reached (see Operating Procedure). 2. Wearing safety glasses, pull the ring on the safety valve to release pressure from compressor tank. Use your other hand to deflect fast- moving air from being directed toward your face. MOIStUre In COMPreSSeD aIr Moisture in compressed air will form into droplets as it comes from an air compressor pump. When humidity is high or when a compressor is in continuous use for an extended period of time, this moisture will collect in the tank. When using a paint spray or sandblast gun, this water will be carried from the tank through the hose, and out of the gun as droplets mixed with the spray material. IMPOrtant: This condensation will cause water spots in a paint job, especially when spraying other than water based paints. If sandblasting, it will cause the sand to cake and clog the gun, rendering it ineffective. A filter in the air line (MP3105), located as near to the gun as possible, will help eliminate this moisture. 3. The safety valve should automatically close at approximately 40-50 psi. If the safety valve does not allow air to be released when you pull on the ring, or if it does not close automatically, it MUST be replaced. DraIn tank With compressor shut off and pressure released, drain moisture from tank by opening drain valve underneath tank. Figure 6 CleanInG Turn power OFF and clean dust and dirt from pump cover, tank, and air lines. IMPOrtant: Unit should be located as far from spraying area as hose will allow to prevent over-spray from clogging air filter. lUbrICatIOn This is an oilless type compressor requiring no lubrication. therMal OVerlOaD PrOteCtOr This compressor is equipped with a thermal overload protector which will shut off motor if it becomes overheated. If thermal overload protector shuts motor OFF frequently look for the following causes: 1. Low voltage 2. Lack of proper ventilation If the thermal overload protector is actuated, the motor must be allowed to cool down before start-up is possible. lUbrICatIOn 1. Turn ON / OFF switch to the OFF position. 2. Unplug power cord from wall outlet and wrap around handle area to prevent damage when not in use. 3. Wearing safety glasses drain tank of air by pulling the ring on the safety valve. Use other hand to deflect fast moving air from being directed toward your face. 4. Drain tank of condensation by opening drain valve on bottom of tank. Tank pressure should be below 10 psi when draining tank. 5. Air hose should be disconnected from compressor and hung open ends down to allow any moisture to drain. 6. Compressor and hose should be stored in a cool, dry place. 4 FP209800 notes 5 Oilless Compressors troubleshooting Chart Symptom Possible Cause(s) Corrective action Compressor will not run 1. Switch in OFF position 2. No electrical power at wall outlet 3. Compressor has reached automatic shutoff pressure 4. Motor overheated 5. Loose electrical connection 6. ON / OFF switch bad 7. Pressure switch bad 8. Defective motor 1. Make sure compressor is plugged in and switch is ON 2. Check circuit breaker or fuse at electrical panel. 3. Release air from tank until compressor restarts automatically 4. Allow compressor to cool for approximately 30 minutes so thermal overload switch will reset. Make sure compressor is run in a clean, well-ventilated area where temperature will not exceed 100°F. 5. Check all electrical connections 6. Replace ON / OFF switch 7. Replace pressure switch 8. Replace pump / motor assembly Thermal overload 1. Lack of proper ventilation/room 1. Move compressor to a clean,well ventilated area where protector cuts out temperature too high temperature will not exceed 100°F. repeatedly 2. Decrease usage or purchase unit with h...
Dieses Handbuch ist für folgende Modelle:Pumps - FP209800 (2.86 mb)