Anleitung Zusammenfassung


To Drain Tank 1. Set the Auto/On/Off switch to "OFF". 2. Turn regulator knob counterclockwise to set the outlet pressure to zero. 3. Remove the air tool or accessory. 4. Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring. 5. Drain water from air tank by opening drain valve (counter-clockwise) on bottom of tank. NOTE: Tilt tank forward to drain tank completely. Water will condense in the air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture. 6. After the water has been drained, close the drain valve (clockwise). The air compressor can now be stored. NOTE: If drain valve is plugged, release all air pressure. The valve can then be removed, cleaned, then reinstalled. ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE PERFORMED BY TRAINED SERVICE TECHNICIAN. 13 641915-00,FSCP200 Compressor 3/14/06 7:31 AM Page 14 STORAGE Before you store the air compressor, make sure you do the following: 1. Review the "Maintenance" section on the preceding pages and perform scheduled maintenance as necessary. 2. Set the Auto/On/Off lever to "OFF". 3. Turn regulator knob counterclockwise and set the outlet pressure to zero. 4. Remove the air tool or accessory. 5. Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring. 6. Drain water from air tank by opening drain valve on bottom of tank. Water will condense in the air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture. 7. After the water has been drained, close the drain valve. NOTE: If drain valve is plugged, release all air pressure. The valve can then be removed, cleaned, then reinstalled. 8. Protect the electrical cord and air hose from damage (such as being stepped on or run over). Wind them loosely around the compressor handle. (If so equipped) 9. Store the air compressor in a clean and dry location. 14 641915-00,FSCP200 Compressor 3/14/06 7:31 AM Page 15 TROUBLESHOOTING Performing repairs may expose voltage sources, moving parts or compressed air sources, personal injury may occur. Maintenance other than that recommended in the “Troubleshooting” section of this manual is not recommended and should be performed by trained service personnel. PROBLEM CAUSE CORRECTION Compressor does not turn off when compressor reaches "cut-out" pressure. Pressure switch "cut-out" too high. Set Auto/On/Off switch to the "OFF" position, if the unit does not shut off contact a Trained Service Technician. Contact a Trained Service Technician. Excessive tank pressure - safety valve pops off. Tube fittings are not tight enough. Using a soapy water solution check all exposed fittings for leaks. If needed reseal fittings with pipe sealant tape and retighten securely. Do Not Overtighten. If leaks continue contact a Trained Service Technician. Air leaks at fittings. Air leaks in air tank or at air tank welds. Defective air tank. Air tank must be replaced. Do not repair the leak. Do not drill into, weld or otherwise modify air tank or it will weaken. The tank can rupture or explode. Low voltage. Extension cord is wrong length or gauge. Check extension cord. Thermal overload protector cuts out repeatedly. Improper ventilation/ temperature too high. Operate compressor in a well ventilated area. Defective check valve. Contact a Trained Service Technician. Defective valves. Contact a Trained Service Technician. 15 641915-00,FSCP200 Compressor 3/14/06 7:31 AM Page 16 PROBLEM CAUSE CORRECTION Air leak from safety valve. Possible defect in safety valve. Operate safety valve manually by pulling on ring. If valve still leaks, it should be replaced. Pressure reading on the regulated pressure gauge drops when an accessory is used. It is normal for "some" pressure drop to occur. If there is an excessive amount of pressure drop when the accessory is used, adjust the regulator following the instructions in the "Description of Operation" paragraph in the "Operation Section. NOTE: Adjust the regulated pressure under flow conditions (while accessory is being used). Compressor is not supplying enough air to operate accessories. Prolonged excessive use of air. Compressor is not large enough for air requirement. Decrease amount of air usage. Check the accessory air requirement. If it is higher than the SCFM or pressure supplied by your air compressor, you need a larger compressor. Hole in hose. Check and replace if required. Air leaks. Tighten fittings. Excessive "auto" starting and stopping Condensation in tank Drain tank 16 641915-00,FSCP200 Compressor 3/14/06 7:31 AM Page 17 PROBLEM CAUSE CORRECTION Motor will not run. Check fuse box for blown fuse and replace as necessary. Reset circuit breaker. Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch circuit. Check for proper fuse. You should use a time delay f...

Dieses Handbuch ist für folgende Modelle:
Pumps - FSCP200 (497.56 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien