Anleitung Friedrich, modell DUCTLESS SPLIT SYSTEMS M36TYF1

Hersteller: Friedrich
Dateigröße: 127.25 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


in 1/4" 1/4" 1/4" 1/4" 1/4" 1/4" SUCTION LINE O.D. in 3/8" 3/8" 3/8" 3/8" 1/2" 3/8" FACTORY PRECHARGE ft 165' 165' 165' 165' 165' MAx. LINE LENGTH ft Each unit:82 Total:230 Each unit:82 Total:230 Each unit:82 Total:230 Each unit:82 Total:230 Each unit:82Total:230 MAx. HEIGHT DIFFERENCE ft 49' 49' 49' 49' 49' DIMENSIONS & WEIGHT INDOOR UNIT W x H x D in 31 1/8" x 10 7/8" x 8 1/2" ea. 31 1/8" x 10 7/8" x 8 1/2" ea. 31 1/8" x 10 7/8" x 8 1/2" 31 1/8" x 10 7/8" x 8 1/2" 31 1/8" x 10 7/8" x 8 1/2" NET WEIGHT lbs 21 ea. 21 ea. 21 21 21 ea. 21 ea. 21 21 ea. SHIPPING WEIGHT lbs 26 ea. 26 ea. 26 26 26 ea. 26 ea. 26 26 ea. OUTDOOR UNIT W x H x D in 35 3/8" x 32 5/8" x 13" 35 3/8" x 32 5/8" x 13" 35 3/8" x 32 5/8" x 13" 35 3/8" x 32 5/8" x 13" 35 3/8" x 32 5/8" x 13" NET WEIGHT lbs 149 149 149 149 149 SHIPPING WEIGHT lbs 167 167 167 167 167 NOTE: All models have low ambient capabilities built-in. Capacity is reduced as 0 degrees Fahrenheit is approached. NOTE: All R410A models have 1/2. UNF 20 thread per inch charging and vacuuming ports. An adapter must be used for 1/4. gauges. Adapter part number 67270018 is available through Friedrich parts distributors. Due to continuing research in new energy-saving technology, specifications are subject to change without notice. Refrigeration line sets USED WITH: LENGTH-FT. LIQUID SUCTION kIT# All 9000 and 12000 Btu indoor units 15' 1/4” 3/8” T32150 35' 1/4” 3/8” T32350 MW18Y3FM 15' 1/4” 1/2” T42150 indoor units 35' 1/4” 1/2” T42350 Insulated line sets are available for all Friedrich split systems in 15 ft. and 35 ft. lengths. Each line set is equipped with flare nuts on both ends. Both liquid and suction lines are insulated. Line sets can be joined together with field supplied double female connectors. Each system requires one line set for each indoor unit installed. On multi-zone systems, line sets should be ordered based on individual indoor unit capacities not total system capacity. For example, a M18DYF uses 2 line sets for 9,000 Btu units, not 1 for the 18,000 Btu product. Ductless_Tri_Zone_Heat_Pump_Submittal_11 ...

Dieses Handbuch ist für folgende Modelle:
Pumps - DUCTLESS SPLIT SYSTEMS M30TYF (127.25 kb)
Pumps - DUCTLESS SPLIT SYSTEMS M27TYF (127.25 kb)
Pumps - DUCTLESS SPLIT SYSTEMS M33TYF (127.25 kb)
Pumps - DUCTLESS SPLIT SYSTEMS M36TYF2 (127.25 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien