Login:
Stimmen - 4, Durchschnittliche Bewertung: 4.3 ( )

Anleitung Hitachi, modell 240353

Hersteller: Hitachi
Dateigröße: 624.57 kb
Dateiname: 2ada3407-d055-4935-8beb-efeefa1a1abf.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Dieses Gerät hat auch andere Anweisungen:
Pumps - 240353 (576.5 kb)

Anleitung Zusammenfassung


C First choice when quality counts. This gun and hose for Delta Spray Air Spray package or Delta Spray HVLP package This gun and hose for PRO 3500sc Electrostatic package INSTRUCTIONS–PARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. ACETAL HUSKY 307, WALL-MOUNT PUMP, DRUM SUCTION PRO/ Delta Spray Packages Metal fluid fittings and hose couplings are stainless steel. 100 psi (0.7 MPa, 7 bar) Maximum Fluid Working Pressure 100 psi (0.7 MPa, 7 bar) Maximum Air Inlet Pressure Packages with Fluid Pressure Regulators Model No. 240–349 with hoses and Delta Spray air spray gun Model No. 240–350 with hoses and Delta Spray HVLP gun Model No. 240–351 no hoses or gun Model No. 240–352 with hoses and PRO 3500sc electrostatic gun Model No. 240–353 with hoses and PRO 4500sc electrostatic gun Packages with Surge Tanks Model No. 240–361 with hoses and Delta Spray air spray gun Model No. 240–362 with hoses and Delta Spray HVLP gun Model No. 240–363 no hoses or gun GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441 Graco Inc. is registered to I.S. EN ISO 9001 This manual contains changes not included throughout the contents. Please see the second page of this book (page 1A) for a description of the revisions and additions. Parts Contents Instruction Manual – Parts List Changes This page contains a summary of changes or additions that do not appear in the contents of the manual. (Text Box comment Improve pressure control instructions (Graco Ref. 6557). Change 30psi HVLP fluid regulator and gauge to a 60psi gauge and regulator. Obsolete suction tube (Graco Ref. 6557).) 308845 1A Notes 308845 1B Table of Contents Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Parts List and Parts Drawing 240–349 to 240–353 . . . . . . . . . . . . . . . . . . 10 240–361 and 240–363 . . . . . . . . . . . . . . . . 12 Fluid Filter Kit 240–440 . . . . . . . . . . . . . . . . . . . 14 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Wall Mounting Hole Layout . . . . . . . . . . . . . . . . 15 Graco Standard Warranty . . . . . . . . . . . . . . . . . 16 Graco Phone Number. . . . . . . . . . . . . . . . . . . . . 16 Symbols Warning Symbol WARNINGWARNING This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions. Caution Symbol CAUTION This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the corresponding instructions. WARNING PRESSURIZED FLUID HAZARD Spray from the gun, hose leaks, or ruptured components can splash fluid in the eyes or on the skin and cause serious injury. . Do not stop or deflect fluid leaks with your hand, glove, or rag. . Follow the Pressure Relief Procedure on page 6 before cleaning, checking, or servicing the equipment. . Tighten all fluid connections before each use. . Check the hoses, tubes, and couplings daily. Replace parts immediately if worn, damaged, or loose. Permanently coupled hoses cannot be repaired. FIRE AND EXPLOSION HAZARD Improper grounding, poor air ventilation, open flames, or sparks can cause a hazardous condition and result in fire or explosion and serious injury. . Ground the equipment, personnel in or close to the spray area, the object being sprayed, and all other electrically conductive objects in the spray area. See Grounding on page 5. . If there is any static sparking while using the equipment, stop spraying immediately. Identify and correct the problem. . Provide fresh air ventilation to avoid the buildup of flammable vapors from the solvent or the fluid being sprayed. . Do not smoke in the spray area. . Extinguish all open flames or pilot lights in the spray area. . Do not turn on or off any light switch in the spray area. . Electrically disconnect all equipment in the spray area. . Keep the spray area free of debris, including solvent, rags, and gasoline. . Do not operate a gasoline engine in the spray area. . . WARNING INSTRUCTIONS EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture, malfunction, or start unexpectedly and result in a serious injury. . This equipment is for professional use only. . Read all the instruction manuals, tags, and labels before operating the equipment. . Use the equipment only for its intended purpose. If you are uncertain about usage, call your Graco distributor. . Do not alter or modify this equipment. Use only genuine Graco parts and accessories. . Check the equipment daily. Repair or replace worn or damaged parts immediately. . Do not exceed the maximum working pressure of the lowest rated system component. This package has a 100 psi (0.7 ...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien