Login:
Stimmen - 1, Durchschnittliche Bewertung: 4 ( )

Anleitung Dimplex, modell SI 7CS

Hersteller: Dimplex
Dateigröße: 1.19 mb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


5CS to .. 17CS APPENDIX: 12.4 WIRING DIAGRAMS 0 VAC C 7 J1-G0 230 VAC - 50Hz 230 VAC 24 VAC T1 1 2 p o l . 1 2 p o l . PE Netz X1 3 N 4 , 0 A T r F3 L 4 , 0 A T r F2 J18-C13 X2-G X3 J2 B 2 24VAC 0 VAC R2 B 1 J1 J5-IDC1 G G 0 R7 B C 5 B 3 J3 + V D C G N D B 5 B 4 B C 4 J9 J10 N1 Verdi. N O 3 J11 J12 V2 N O 2 F2 (L) K1-A1 C 1 V1 N O 1 X2 24VAC J1-G V G J4 Y 1 Y 4 Y 3 Y 2 V G 0 Sto.-M1 A3 A4 A2 Sto.-M11 ID C 1 A1 SPR ID 1 EVS ID 8 J5 ID 7 ID 6 ID 3 ID 2 ID 4 ID 5 C 4 C 1 J13 N O 6 N O 5 C 4 N O 4 K5-A1 F3 (L) K5 A1 K1 A2 A1 A2 0 VAC J5-IDC1 N O 1 2 B 8 X4 R6 EGS J6 B 7 B 6 J13-C4 G N D J7 ID 1 0 ID 1 1 ID 1 2 ID C 9 ID 9 N O 9 C 9 J14 N O 7 J15 C 7 N O 8 C 8 N C 8 J16 N O 1 0 N O 1 1 C 9 Verd.1 J12/NO1 HD ND F5 P < P > F4 J8 ID 1 3 ID 1 4 ID 1 3 H ID C 1 3 ID 1 4 H PUP J12/NO3 C 1 2 J17 J18 N C 1 2 N C 1 3 N O 1 3 C 1 3 F4 F5 J12-C1 J12-C1 Mains system 30 12.4.2 Load .. 5CS to .. 17CS APPENDIX: 12.4 WIRING DIAGRAMS N7 3 M U V M1 Sanftanlasser nicht vorhanden in Sole/Wasser 5C und 7C W X5 3/PE 400VAC - 50Hz Netz 3 S 2 4 R 1 3 K1 6 T /1.8 5 PE L3 L2 L1 M11 Vor dem Einklemmen des M11 (PUP) -Motorschutzes (F15) (ab -9CS bis -17CS) die Drahtbrucke A3 entfernen. A3 ist die Brucke "Storung M11" X2 (24 VAC) Blatt1 / N1 3 M SSM F15 SSM J5 / ID5 L2 PE PE L1 X1 L3 K5 2 4 6 1 3 5 /1.8 Mains system No soft starter fitted in brine-to-water units 5C and 7C Sheet 1/N1 Remove wire jumper A3 prior to connecting M11 circulating pump motor protection (F15) (from –9CS to –17CS). A3 is the „M11 fault“ jumper 31 12.4.3 Terminal Diagram .. 5CS to .. 17CS APPENDIX: 12.4 WIRING DIAGRAMS 230 VAC - 50Hz 2ter Sperreingang Kontakt offen = WP gesperrt Sto.- M1 Sto.- M11 F3 4, 0 A Tr J11 F2 (L) J12 K5-A1 J13 F3 (L) B C 5 X3 R2 B 1 R1 G G 0 J1 N1 J9 J10 R3 C o d . -W P R7 B 2 B 3 J2 + V D C B C 4 G N D B 5 B 4 J3 Kontakt offen = WP gesperrt Die Funktion von E10 ist wahlbar B3 T< V G V G 0 Y 1 Y 4 Y 3 Y 2 J4 EVS B4 T< SPR ID 1 ID 8 ID 7 ID 6 ID 3 ID 2 ID 4 ID 5 J5 N O 1 N O 2 N O 3 K1-A1 C 1 C 1 Verdi. V1 V2 3L/PE 400VAC - 50Hz Netz L 2 X5 L 1 L 3 P E 4 xxxxx M11 2 C 4 N O 5 N O 4 N O 6 C 4 -PE -N X1 -N X1 -PE -N X1 X1 HK H e i z s t a b oder M13 E10 X1 12 p ol . 12 p ol . PE 3 N M18 Netz J14 J15 J16 J17 J18 X4 24VAC B 7 J6 A3 A4 0 VAC X2 R5 ID C 1 J1-G0 B 6 J1-G P< B2 G N D B 8 ID 1 0 ID 1 1 ID 1 2 ID C 9 ID 9 J7 ID 1 3 H ID C 1 3 ID 1 4 H ID 1 3 ID 1 4 J8 -N 4, 0 A Tr 4 3 N O 7 C 7 -PE -N MA N O 8 N C 8 C 7 C 8 -PE X1 MZ -N F2 N O 9 N O 1 0 N O 1 1 C 9 C 9 X1 -PE -N X1 L X1 3 2 3 4 C 1 3 N O 1 3 N O 1 2 N C 1 2 C 1 2 X1 -PE MAN -N MZN N C 1 3 3 K20 N10 M21 M16 K21 M15 M22 E9 K11 K12 T 1 L 1 max. 200W A 2 ( - ) A 1 ( + ) J 1 3 - C 4 L 1 T 1 M19 A 1 ( + ) A 2 ( - ) J 1 4 - C 7 H5 max. 200W N11 X1 - N K22 K23 R6 Leitungen sind bei Bedarf bauseits zu erstellen 0 VAC J5-IDC1 Mains system Contact open = HP disabled Function E10 is selectable 2nd disable input Contact open = HP disabled Lines to be field-connected, if required Mains system 230 VAC - 50 Hz APPENDIX: 12.4 WIRING DIAGRAMS 12.4.4 Legend .. 5CS to .. 17CS A1 Wire jumper, must be removed if a utility company disable contactor is used A2 Wire jumper, must be removed if 2nd disable input is used A3 Wire jumper, must be removed if a motor protection contact for primary pump is used A4 Wire jumper, must be removed if a motor protection contact for the compressor is used Open wire jumpers or contacts mean: lock-out or malfunction B2* Pressostat low pressure, brine B3* Thermostat, hot water B4* Thermostat, swimming pool water E9* Electr. immersion heater, hot water E10* Suppl. heating system (boiler or electr. heating element) F2 Load fuse for N1 relay outputs across J12 and J13 4.0 A slow F3 Load fuse for N1 relay outputs across J15 to J18 4.0 A slow F4 Pressostat high pressure F5 Pressostat low pressure (in SI 17CS, F5 is a limiter with manual reset) F15* Motor protection M11, from SI 9CS to SI 17CS integrated in primary pump H5* Lamp, remote fault indicator J1...J18 Terminal connector at N1 K1 Contactor, compressor K5 Contactor, primary pump K11* Electron. relay for remote fault indicator (relay module) K12* Electron. relay for swimming pool water circulating pump K20* Contactor, suppl. heating system K21* Contactor, electr. immersion heater, hot water K22* Utility company disable contactor K23* SPR auxiliary contactor M1 Compressor M11* Primary pump M13* Heating circulating pump M15* Heating circulating pump for heating circuit 2 M16* Suppl. circulating pump M18* Hot water circulating pump M19* Swimming pool circulating pump M21* Mixer heating circuit 1 M22* Mixer heating circuit 2 N1 Heat pump controller N7 Soft start control (not fitted in SI 5CS and SI 7CS appliances) N10* Remote control station N11* Relay module R1 External sensor R2 Return sensor R3 Hot water sensor (as an alternative to hot water thermostat) R5 Sensor for heating circuit 2 R6 Freeze protection sensor R7 Coding resistor 8k T1 Safety isolating transformer 230/24V AC-28V A X1 Terminal strip mains control L/N/PE-230V AC-...

Dieses Handbuch ist für folgende Modelle:
Pumps - SI 11CS (1.19 mb)
Pumps - SI 14CS (1.19 mb)
Pumps - SI 17CS (1.19 mb)
Pumps - SI 21CS (1.19 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien