Login:
Stimmen - 1, Durchschnittliche Bewertung: 4 ( )

Anleitung Dimplex, modell LI AS

Hersteller: Dimplex
Dateigröße: 236.9 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


packaging kg 5 ELECTRICAL CONNECTIONS 5.1 Nominal voltage; fusing V/A 5.2 Nominal power consumption 1) A2 W35 kW 5.3 Starting current with soft starter A 5.4 Nominal current A2 W35/cos A /--6 COMPLIES WITH EUROPEAN SAFETY REGULATIONS 7 OTHER DESIGN CHARACTERISTICS 7.1 Defrosting Type of defrosting Defrost pan available 7.2 Heating water inside unit protected against freezing 2) 7.3 Performance settings 7.4 Controller internal / external LI11MS IP 21 Indoors Max. 55 / min. 18 -20 to +35 7.5 7.6 / 2.9 9.1 / 3.4 9.0 / 2.5 10.9 / 4.1 12.0 / 4.6 55 / 61 1.0 / 3000 4200 / 0 2500 / 25 R404A / 2.5 1360 x 750 x 850 G 1” ext. thread 500 x 500 200 230 / 25 2.65 38 14.4 / 0.8 4) Automatic Cycle reversal Yes (heated) Yes 1 External LI16AS IP 21 Indoors Max. 55 / min. 18 -20 to +35 7.5 9.8 / 2.6 12.2 / 3.2 11.5 / 2.4 15.4 / 3.7 16.1 / 3.8 57 / 62 1.4 / 4500 5200 / 0 4000 / 25 R404A / 3.1 1570 x 750 x 850 G 1” ext. thread 570 x 570 235 400 / 20 3.81 25 6.9 / 0.8 4) Automatic Cycle reversal Yes (heated) Yes 1 External 1) This data characterises the size and performance capacity of the system. For economic and energy consumption reasons, additional factors such as defrosting behaviour, bivalence point and control need to be taken into consideration. Abbreviations have the following meaning e.g. A2 / W55: heat source temperature 2°C and heating water supply temperature 55°C. 2) The heat circulating pump and the controller of the heat pump must be on standby at all times. 3) See operating limits diagram. 4) See CE Declaration of Comformity. Subject to technical modifications DIMENSIONS AND CONNECTIONS 4x Internal screw thread M8x15 Condensate drain inside 30mm Heating water supply. Heat pump outlet 1" external threadHeating water return. Heat pump inlet 1" external threadElectrical lines Direction of air flow 750 850 1360 / 1570 TYPICAL SYSTEM CONFIGURATION AND ACCESSORIES The diagram below shows a typical LI MS / LI AS heat LKL LKB Heat Pump Qty pump configuration for heating and domestic hot water Heat Pump LKK LI 11 MS or Indoor air source heat pump (single phase) 1 including typical accessories required for a single Control 600/700 LI 16 AS Indoor air source heat pump (three phase) 1 Heating and Hot Water Accessories PSP 890 140L built-under buffer tank 1 KPV25 Compact manifold 1 LI 11MS / LI 16AS Heat Pump Buffer Tank VTB25 Heating Circuit DHW Cylinder heating circuit. (Note this is for illustrative purposes only and is not intended as a full hydraulic schematic) RSG 600/700 KPV25 WWM25 WWM25 Heating circuit/hot water module 1 VTB25 Manifold bar 1 Controller Accessories EVL 995/6/7/8 – 1 Heat pump/controller connecting cable 1 Ducting Accessories LKL 600/700 Long, short or 90° elbow ducts LKB 600/700 1 or 2 (dependent on requirement) LKK 600/700 DMK 600/700 Sealing collar 1 pair RSG 600/700 Rain guard 2 TRUST OUR EXPERIENCE As the world's largest manufacturer of electrical heating technology, Dimplex has been at the forefront of product development and innovation for nearly 60 years. We are well respected within the construction industry for producing products of the highest specification and quality and for our pre and post sales support. At our manufacturing plant in Kulmbach, Germany, we have been developing and producing innovative heat pumps for over 30 years. EVERYTHING'S A MATTER OF PROPER PLANNING Heat pumps are one of the most efficient and economical Heat Pump Installer Partner APPRO ED heating systems provided the individual components of the heat pump system, including the heat source, heat pump and connected heating system are properly matched. SPECIFICATIONS Dimplex policy is one of continuous improvement; the Company therefore reserves the right to alter specifications without notice. Although every care has been taken in the reproduction of product finishes in this brochure, photographs should be taken only as a guide. The information is correct at the time of printing. CE MARK Products carrying the CE mark comply with European safety standards and the European Standard for electro-magnetic compatibility. FURTHER INFORMATION For more information on Dimplex heat pumps please speak to your local Designed by (Bournemouth). Dimplex can provide advice and guidance on the correct Dimplex Installer Partner or contact us directly: heat pump for your application and our network of experienced, fully trained Tel: 0870 077 7117 Fax: 0870 727 0114 installers will provide complete system planning assistance, installation and Email: marketing@glendimplex.com Website: comprehensive after-sales service. CERTIFIED QUALITY Maximum operational reliability of all Dimplex appliances is ensured at all times due to continuous quality assurance during production and quality certification to EN ISO 9001. The international heat pump quality label for heat pump heating systems guarantees highest safety and quality standards.The tests conducted by recognised testing institutes provide comparability of results, ensu...

Dieses Handbuch ist für folgende Modelle:
Pumps - LI MS (236.9 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien