Login:
Stimmen - 3, Durchschnittliche Bewertung: 4.3 ( )

Anleitung Fedders, modell CH42ACD1VF

Hersteller: Fedders
Dateigröße: 131.37 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Mounting Pad Size (inches) Ship / Operating Weight (lbs) CH18ABD1VF 1 1.2 R-22 18,000 13.5 20 32 1.2 X 21 1.2 X 21 1.2 24 x 24 132 / 127 CH24ACD1VF 2 R-22 24,000 16.0 25 32 1.2 X 29 1.2 X 29 1.2 32 x 32 195 / 186 CH30ACD1VF 2 1.2 R-22 30,000 18.8 30 32 1.2 X 29 1.2 X 29 1.2 32 x 32 195 / 186 CH36ACD1VF 3 R-22 36,000 20.5 35 32 1.2 X 29 1.2 X 29 1.2 32 x 32 197 / 188 CH42ACD1VF 3 1.2 R-22 42,000 24.8 40 32 1.2 X 29 1.2 X 29 1.2 32 x 32 208 / 201 CH48ACD1VF 4 R-22 48,000 27.3 45 32 1.2 X 29 1.2 X 29 1.2 32 x 32 212 / 203 CH60ACZ1VF 5 R-410A 60,000 38.4 60 39 X 29 1.2 X 29 1.2 32 x 32 258 / 249 Product Specifications PHYSICAL DATA MODEL SIZE 18 24 30 36 42 48 60 PERFORMANCE DATA NOMINAL CAPACITY (BTUH) 18,000 24,000 30,000 36,000 42,000 48,000 60,000 FAN DATA FAN MOTOR TYPE PSC PSC PSC PSC PSC PSC PSC HP 1/5 1/3 1/3 1/3 1/3 1/3 1/3 DIAMETER 18" 22" 22" 22" 22" 22" 24" BLADE 3 3 3 3 3 3 3 RPM 1,050 1,050 1,050 1,050 1,050 1,050 950 CFM 1,800 3,400 3,400 3,400 3,400 3,400 4,000 OUTDOOR COIL TYPE Enhanced Aluminum Plate Fin / Rifled Copper Tube COIL FACE AREA (ft2) 12.2 18.2 18.2 18.2 18.2 18.2 22.2 O.D. 3/8" 7mm 7mm 7mm 7mm 7mm 7mm FPI / ROWS 18-1 18-2 18-2 18-2 18-3 18-3 18-3 ELECTRICAL DATA (208/230 – 1-60, VOLTAGE RANGE 197V - 253V) MINIMUM CIRCUIT AMPACITY - MCA (amps) 2 13.5 16.0 18.8 20.5 24.8 27.3 38.5 MAXIMUM OVERCURRENT PROTECTIVE DEVICE-MOCP(amps)3 20 25 30 35 40 45 50 COMPRESSOR RLA (Rated Load Amps) 10.0 11.4 13.6 15 18.4 20.9 29.4 COMPRESSOR LRA (Locked Rotor Amps) 41 56 67 73 95 109 134 FAN MOTOR FLA (Full Load Amps) 1.4 1.8 1.8 1.8 1.8 1.8 1.9 REFRIGERANT CONNECTIONS LIQUID LINE CONNECTION SIZE (In. OD) 3/8 3/8 3/8 3/8 3/8 3/8 3/8 SUCTION LINE CONNECTION SIZE (In. OD) 3/4 3/4 7/8 7/8 7/8 7/8 7/8 RECOMMENDED LINE SET LIQUID TUBE DIAMETER (In. OD) 3/8 3/8 3/8 3/8 3/8 3/8 3/8 RECOMMENDED LINE SET SUCTION DIAMETER (In. OD) 3/4 3/4 7/8 7/8 7/8 1 1/8 1 1/8 FACTORY CHARGE - OZ. 103 164 154 164 207 233 233* NOTE: Control circuit is 24V on all units and requires external power source. Copper wire must be used from service disconnect to unit. ALL motors/compressors contain internal overload protection. 1. Wire size should be determined in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes. 2. Time delay fuses may be used in place of HACR circuit breaker. * Unit uses R-410A refrigerant. 2 Specifications subject to change without notice. Product Specifications ARI CERTIFIED COMBINATION RATINGS UNIT SIZE OUTDOOR MODEL INDOOR MODEL FACTORY SUPPLIED ENHANCEMENT COOLING HEATING TOTAL CAPACITY SEER EER HIGH TEMP LOW TEMP HSPF CAPACITY COP CAPACITY COP 18 CH18ABD1VF AFPB24A1 TXV, TDR 18,000 13.0 11.0 17,300 3.42 11,100 2.36 8.2 CH18ABD1VF AFPB24B1 TXV, TDR 18,000 13.0 11.0 17,300 3.42 11,100 2.36 8.2 24 CH24ACD1VF AFPB24B1 TXV, TDR 24,000 13.0 11.4 24,000 3.42 15,000 2.20 8.2 30 CH30ACD1VF AFPB36A1 TXV, TDR 28,000 13.0 11.5 28,000 3.50 18,200 2.30 8.2 36 CH36ACD1VF AFPB36A1 TXV, TDR 34,000 13.0 11.5 34,000 3.50 ...

Dieses Handbuch ist für folgende Modelle:
Pumps - CH18ABD1VF (131.37 kb)
Pumps - CH24ACD1VF (131.37 kb)
Pumps - CH30ACD1VF (131.37 kb)
Pumps - CH36ACD1VF (131.37 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien