Login:
Stimmen - 2, Durchschnittliche Bewertung: 4 ( )

Anleitung Giant, modell THE EAGLE LINE P219

Hersteller: Giant
Dateigröße: 163.2 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Gas engine power outputs must be approximately twice the pump power requirements shown above. We recommend a 1.15 service factor be specified when selecting an electric motor as the power source. To compute specific pump horse power requirements, use the following formula: HP = (GPM X PSI) / 1450 5 Specifications Model P220A U.S...............................Metric Flow.....................................................................4.7 GPM......................17.8 LPM Pressure (Continuous).......................................2000 PSI......................140 Bar Pressure (Intermittent) .......................................2500 PSI......................175 Bar Maximum Crankshaft Speed ................................................................... 1750 RPM Maximum Inlet Pressure....................................145 PSI........................10 bar Plunger Diameter...............................................0.71”............................18 mm Stroke..................................................................0.56”............................14.1 mm Max. Temperature of Pumped Fluids...............160o F...........................71oC Inlet Ports...................................................................................................(2) 1/2" BSP Discharge Ports.........................................................................................(2) 3/8" BSP Shaft Rotation.......................................................Top of Pulley Towards Fluid End Crankshaft Diameter..........................................0.98”............................24 mm Key Width..........................................................0.31”............................8 mm Shaft Mounting...................................................Right Side Facing Manifold Weight.................................................................11.7 lbs........................5.3 Kg Crankcase Oil Capacity.....................................7.5 fl.oz.......................0.22 Liter Extended Crankcase Oil Capacity....................9.0 fl.oz.......................(0.27 Liter Volumetric Efficiency @ 1750 RPM ...................................................... 0.94 Volumetric Efficiency @ 3450 RPM ...................................................... 0.87 Mechanical Efficiency @ 3450 RPM...................................................... 0.86 Consult the factory for special requirements that must be met if the pump is I to operate beyond one or more of the limits specified above. I NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o’clock position. Exchange the oil fill and the oil drain plugs, also. Refer to the repair instructions as necessary for the proper assembly sequence. P220A HORSEPOWER REQ UIREMEN TS RPM GPM 1000 PS 1500 PSI 1750 PSI 2000 PSI 2500 PSI* 250 0.7 0.5 0.7 0.8 1.0 1.2 500 1.3 0.9 1.3 1.6 1.8 2.2 1000 2.7 1.9 2.8 3.1 3.7 4.7 1450 3.9 2.7 4.0 4.6 5.4 6.7 1750 4.7 3.2 4.9 5.5 6.5 HORSEPOWER RATINGS: The rating shown are the power requirements for the pump. Gas engine power outputs must be approximately twice the pump power requirements shown above. We recommend a 1.15 service factor Intermittent duty only be specified when selecting an electric motor as the power source. To compute specific pump horse power requirements, use the following formula: HP = (GPM X PSI) / 1450 6 Specifications Model P221A U.S...............................Metric 1750 RPM+ Flow (Continuous) @ 2000 PSI (140 Bar)......2.3 GPM......................8.9 LPM Flow (Intermittent) @ 2500 PSI (175 Bar)......2.3 GPM......................8.9 LPM 3450 RPM+ Flow (Continuous) @ 2000 PSI (140 Bar)......4.2 GPM......................15.9 LPM Flow (Intermittent) @ 2500 PSI (175 Bar)......4.2 GPM......................15.9 LPM Maximum Inlet Pressure....................................145 PSI........................10 bar Plunger Diameter...............................................0.71”............................18 mm Stroke..................................................................0.28”............................7.0 mm Max. Temperature of Pumped Fluids...............160o F...........................71oC Inlet Ports...................................................................................................(2) 1/2" BSP Discharge Ports.........................................................................................(2) 3/8" BSP Shaft Rotation.......................................................Top of Pulley Towards Fluid End Crankshaft Diameter..........................................0.98”............................24 mm Key Width..........................................................0.3...

Dieses Handbuch ist für folgende Modelle:
Pumps - THE EAGLE LINE P218 (163.2 kb)
Pumps - THE EAGLE LINE P217 (163.2 kb)
Pumps - THE EAGLE LINE P220 (163.2 kb)
Pumps - THE EAGLE LINE P221 (163.2 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien