Anleitung Zusammenfassung


Grounded Outlet Grounding Pin Figure 2 - Grounding Method MOISTURE IN COMPRESSED AIR Moisture in compressed air will form compressor pump. When humidity is high use for an extended period of time, this moisture hose. When using a paint spray or sandblast the tank through the hose, and out of the gun material. IMPORTANT: This condensation will cause water spots in a paint job, especially when spraying other than water based paints. cause the sand to cake and clog the gun, rendering it ineffective. the air line (MP3105), located as near to the gun as possible, eliminate this moisture. 3. Check with a qualified electrician or serviceman if grounding instructions are not completely understood, or if in doubt as to whether product is properly grounded. Do not modify plug provided; if it will not fit outlet, have proper outlet installed by a qualified electrician. Never connect ! WARNING green (or green and yellow) wire to a live terminal. Operation BREAK-IN PROCEDURE Do not attach air ! CAUTION chuck or other tool to open end of hose until start-up has been completed and unit checks OK. IMPORTANT: Do not operate compressor before reading instructions or damage may result. 1. With power switch OFF (O), turn regulator knob fully counterclockwise to minimum operating pressure. 2. While unit is still OFF (O), plug in power cord. 3. Turn switch to ON (I) position and run unit for 5 minutes to break in the pump parts. This unit is a NOTICE continuously running compressor. Normal operation causes the regulator to vent air. 4. Attach chuck or other tool to open end of hose. The compressor is now ready to use. The switch should ! CAUTION be in the OFF (O) position when connecting or disconnecting the power cord from the electrical outlet. REGULATOR 1. This regulator controls air pressure to the hose and attachment. 2. Turning knob clockwise increases air pressure at outlet. 3. Turning counterclockwise will lower air pressure at outlet. Wall Mounting This compressor is designed with an option to be hung on a wall or pegboard for convenient storage. It can also be operated while in the hanging position if one of the following conditions is met: 1. If mounted on a wall, mounting hardware is secured into wood or masonry with suitable fasteners. 2. If mounted on drywall or gypsum board, toggle bolts or mounting anchors are strong enough and are properly secure to resist vibration from the compressor. 3. If mounted on a pegboard, other items hung from the pegboard are secure enough to resist vibration from the compressor. Extension cords for 120V/5 Amp Unit Length of Cord (ft) 25 50 100 150 200 250 300 400 500 Gauge of Cord 18 18 14 12 12 10 10 8 8 3 Portable Handheld Air Wall Mounting (Cont.) On the bottom of the compressor are two keyhole-shaped mounting points that are spaced 4 inches apart. The compressor is designed to be hung with the hose outlet pointed downward. When installing on pegboard, hang from 1/4 or 1/8 inch hooks spaced 4 inches apart. When hanging from the wall, accurately space the fasteners exactly 4 inches apart horizontally or the compressor will not line up with the fasteners. The compressor is designed to hang from the head of the screw or nail. Maintenance ! WARNING Disconnect power source then release all pressure from the system before attempting to install, service, relocate or perform any maintenance. Troubleshooting Chart The compressor should be checked often for any visible problems and the following maintenance procedures should be performed each time the compressor is used. 1. Turn power OFF (O) and clean dust and dirt from air lines and vent openings. IMPORTANT: Locate unit as far from spraying area as possible. LUBRICATION This is an oilless NOTICE type compressor requiring no lubrication. THERMAL OVERLOAD PROTECTORS This compressor is ! CAUTION equipped with automatic reset thermal overload protectors which will shut off the motor if it becomes overheated. If thermal overload protectors shut motor OFF (O) frequently, look for the following causes. 1. Low voltage.. 2. Lack of proper ventilation. 3. High ambient temperature. If the thermal ! CAUTION overload protector is actuated, the motor must be allowed to cool down before start-up is possible. The motor will automatically restart without warning if left plugged into electrical outlet and unit is turned on. STORAGE 1. When not in use, store hose and compressor in a cool dry place. 2. Disconnect hose and hang open ends down, to allow any moisture to drain. Technical Service For information regarding the operation or repair of this product, please call 1-800-543-6400. If you are calling from Ohio or outside the continental United States, please call 1-513-367-1182. Symptom Possible Cause(s) Corrective Action Compressor will not run 1. No electrical power 2. Blown fuse 3. Breaker open 4. Thermal overload(s) open 1. Plugged i...

Dieses Handbuch ist für folgende Modelle:
Pumps - FP2032 (79.02 kb)
Pumps - FP2031 (79.02 kb)
Pumps - FP2033 (79.02 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien