|
Anleitung Zusammenfassung
A suggested multiple discharge to service is shown in Figure 3. Do not use in a pressure tank or booster pump application. Pump/Piping Installation PUMP INSTALLATION NOTICE: Use Teflon tape supplied with the pump for making all threaded connections to the pump itself. Do not use pipe joint compounds on the pump: they can react with the plastic in the pump components. 1. Bolt pump to solid, level foundation. 2. Support all piping connected to the pump. 3. Wrap 1-1/2 to two layers of Teflon tape clockwise (as you face end of pipe) on all male threads being attached to pump. 4. Tighten joints hand tight plus 1-1/2 turns. Do not overtighten. NOTICE: Install pump as close to water source as possible. Long piping runs and many fittings create friction and reduce flow. Use schedule 80 or iron pipe. See "Well Pipe Installation" for more information. Figure 4 -Bolt Pump Figure 5 -Independently Down Support All Piping Attached To Pump (IN GALLONS PER MINUTE) 390.262553 390.262653 1-1/2 H,P. 2 H.P. ABOVE TO WATER 10' 15' 20' 5' 10' 15' 20' 61 56 46 69 67 65 62 58 55 45 65 63 60 58 56 54 44 59 56 54 52 52 51 43 52 50 48 45 45 44 37 47 45 42 40 37 34 28 42 38 35 32 27 20 11 34 30 27 23 14 8 -25 18 13 10 14 7 1-1/2" NPT 2" NPT 1-1/2" NPT 2" NPT ELECTRICAL Connection diagram for dual voltage, single-phase motors. Your dual-voltage motor's terminal board (under the motor end cover) will match one of the diagrams below. Follow that diagram if necessary to convert motor to 115 Volt power. 230 Volt to 115 Volt Conversion, Plug-inType: 1. Pull plug 2. Plug in again straight with arrow out from on plug terminal pointing to board; '115 Volts'. Clamp the power cable to prevent strain on the terminal screws. Connect the green (or bare copper) ground wire to the green ground screw. Connect power supply wires to L1 and L2. For 3-phase motors, or if motor does not match these pictures, follow the connection diagram on the motor nameplate. 230 Volt to 115 Volt Conversion, Plug-in Type: Move plug to change voltage. V ,gPoinl Power Supply Wires Clamp the power cable to prevent strain on the spade connectors. Connect the green (or bare copper) ground wire to the green ground screw. 3782tooo Figure 6 -I 15/230V Dual Voltage Single Phase Wiring Diagram. [AWARNIN_Hazardous voltage. Can shock, burn, or cause death. Disconnect power to motor before working on pump or motor. Ground motor before connecting to power supply. WIRING AGround motor before connecting to electrical power supply. Failure to ground motor severe or fatal electrical shock hazard. ADo not ground to a gas supply line. A To avoid dangerous or fatal electrical OFF power to motor before working cal connections. can cause shock, turn on electri- A Supply voltage must be within +10% of name plate voltage. Incorrect voltage can cause fire or damage motor and voids warranty. If in doubt consult a licensed electrician. A Use wire size specified in Wiring Chart (Page 6). If possible, connect pump to a separate branch circuit with no other appliances on it. A Wire motor according to diagram on motor nameplate. If nameplate diagram differs from diagrams above, follow nameplate diagram. 1. Install, ground, wire and maintain this pump in accordance with electrical code requirements. Consult your local building inspector for information about codes. 2. Provide a correctly fused disconnect switch for protection while working on motor. Consult local or national electrical codes for switch requirements. 5 ELECTRICAL (Continued) 3. Disconnect power before servicing motor or pump. If the wiring diagram on motor nameplate against Figure 6. If the disconnect switch is out of sight of pump, lock it open motor wiring diagram does not match the diagrams in and tag it to prevent unexpected power application. Figure 6, follow the diagram on the motor. 4. Ground the pump permanently using a wire of the same IMPORTANT: 115/230 Volt single phase models are size as that specified in wiring chart (below). Make shipped from factory with motor wired for 230 volts. If ground connection to green grounding terminal under power supply is 115 volts, remove motor canopy and re- motor canopy marked GRD. or @. connect motor as shown in Figure 6. Do not try to run motor as received on 115 volt current. 5. Connect ground wire to a grounded lead in the service panel or to a metal underground water pipe or well cas-8. Motor has automatic internal thermal overload protecing at least 10 feet long. Do not connect to plastic pipe or tion. If motor has stopped for unknown reasons, thermal insulated fittings. overload may restart it unexpectedly, which could cause injury or property damage. Disconnect power before ser 6. Protect current carrying and grounding conductors from vicing motor. cuts, grease, heat, oil, and chemicals. 9. If this procedure or the wiring diagrams are confusing, consult a licensed electrician. 7. Connect current carrying conductors to terminals L1 and L2 under motor canopy. When replacing motor, chec...
Dieses Handbuch ist für folgende Modelle:Pumps - HYDROGLASS 390.262653 (477.44 kb)
Pumps - HYDROGLASS 390.262553 (477.44 kb)