Login:
Stimmen - 4, Durchschnittliche Bewertung: 4 ( )

Anleitung Aquacal, modell 100

Hersteller: Aquacal
Dateigröße: 1.63 mb
Dateiname: 75cd2bed-8a75-4829-8603-70aa16224363.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Dieses Gerät hat auch andere Anweisungen:
Pumps - 100 (2.64 mb)enesfr

Anleitung Zusammenfassung


Service adjustments are available to authorized installation and service personnel, only. CAUTION ! Failure to heed the following may result in equipment damage and voiding of manufacturer’s warranty. Heat pumps contain no owner-serviceable components. Owner-initiated adjustments, beyond the controller “LOC” code, must not be attempted. If adjustments are deemed necessary, the owner should contact installing dealer or AquaCal Customer Support at (800) 786-7751. HEATER CONTROLS...continued Start Up & Setting Operating Controls Owner-Level Programming Instructions (Complete) Covered within this section are features and settings typically accessed first by the installer, and then remaining accessible by the end user (owner). These features reside at the Level-1 access point within the microprocessor. 1. Applying Power to The Controller: A. When power is first applied, the controller performs a lamp test and the display will read [888]. Following [888] the software version will display briefly; B. The control will then display the actual water temperature, provided the circulating pump is operating, and adequate water is flowing through the heater; C. If the pool-circulating pump is off, the control will display: [FLO]. This code message indicates no (or insufficient) water is being circulated through the heat pump. 2. Starting the Heat Pump: A. Once electrical power is supplied to the heat pump, sufficient water is circulating, and the heater controller has successfully completed its self-test, the heater is ready to operate; B. The heat pump is shipped with the controller [MODE] function set to “OFF”. There are two ways to switch the heat pump OFF: First Method- One of the functions of the [MODE] button is “OFF”. Second Method- The thermostat set point can be lowered to a position below the minimum temperature setting (45oF); this action will cause the display to read “OFF”. To switch the unit ON, first use the mode button to select the HEAT mode— for Heat Only models—or, if the heat pump is a Heat and Cool model, use the mode button to select one of the following modes: HEAT, COOL, or ACH (Auto-changer over). In the [OFF] mode, the actual water temperature will be displayed as long as the circulating pump is operational and correct water flow is present. In the event water is not circulating through the heat pump (or flow is insufficient), the controller will display the [FLO] (No Water Flow) code message. C. Using the UP ARROW key, increase the desired temperature until it exceeds the value of the actual temperature displayed. (Note: See # “8,” later in this section, if “000” is displayed upon pressing either the up or down arrow keys.) Once the desired temperature has been entered, the display will read the actual temperature and the heat pump will start to operate. Both the compressor and the fan must be operating before the “Heating” LED will illuminate. (Note: When MODE function is OFF, the current water temperature will be displayed; no functions, values, or programming will be available for adjustment.) 3. Turning The Heat Pump Off: A. Method 1: using the [MODE] key, depress the key until the display reads “OFF” The heater will shut off and remain off until the [MODE] key is used the select an operational mode. This is the preferred method for shutting off the heat pump. B. Method 2: using the DOWN key, depress the key until the desired water temperature reaches 45oF (minimum setting); then, depress the DOWN key one more time, causing the display to read “OFF”. This method is typically used in conjunction with 2-wire external controllers; these controllers are equipped with their own thermostats. (Continued on Next Page) HEATER CONTROLS...continued Start Up & Setting Operating Controls Owner-Level Programming Instructions...continued: 4. Selecting Pool/Spa Thermostat Settings: A. Depress the [POOL/SPA] key to toggle between the pool and the spa temperature set points. B. The pool/spa LED indicator lights, located to the left of the temperature display, will confirm the selected set point. 5. Changing The Pool Temperature Set Point: A. Using the [POOL/SPA] key, select the POOL temperature set point. The pool set point indicator light will confirm the selection. B. The pool temperature set point is adjustable from a minimum of 45oF to a maximum of 104oF. Depressing the [UP ARROW] key will raise the set point 1-degree for every push of the button. Depressing the [DOWN ARROW] key will lower the set point 1-degree for every push of the button. 6. Changing The Spa Temperature Set Point: A. Using the [POOL/SPA] key, select the SPA temperature set point. The spa set point indicator light will confirm the selection. B. The spa temperature set point is adjustable from a minimum of 45oF to a maximum of 104oF. Depressing the [UP ARROW] key will raise the set point 1-degree for every push of the button. Depressing the [DOWN ARROW] key will lower the set point 1-degree for every push of the button. 7. Selecting Bet...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien