Hersteller: Carrier
Dateigröße: 323.05 kb
Dateiname: 16824533-aad7-482a-89bd-6ba02f9f0362.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


‡ Required for Low-Ambient Controller (full modulation feature) and MotorMaster Control only. 4 The unit cabinet must have an uninterrupted or unbroken ground to minimize personal injury if an electrical fault should occur. The ground may consist of electrical wire or metal conduit when installed in accordance with existing electrical codes. Failure to follow this warning can result in an electric shock, fire, or death. CONNECT GROUND AND POWER WIRES Connect ground wire to ground connection in control box for Step 12—Start-Up To prevent compressor damage or personal injury, observe the following: • Do not overcharge system with refrigerant. • Do not operate unit in a vacuum or at negative pressure. • Do not disable low-pressure switch. In scroll compressor applications: • Dome temperatures may be hot. safety. Connect power wiring to contactor as shown in Fig.8. DISCONNECT PER N. E. C. AND/OR To prevent personal injury wear safety glasses, protective LOCAL CODES CONTACTOR GROUND FIELD GROUND WIRING FIELD POWER WIRING clothing, and gloves when handling refrigerant and observe the following: • Back seating service valves are not equipped with Schrader valves. Fully back seat (counter clockwise) valve stem before removing gage port cap. Do not vent refrigerant to atmosphere. Recover during system LUG repair or final unit disposal. A91056 Fig. 8—Line Power Connections CONNECT CONTROL WIRING Route 24-v control wires through control wiring grommet and connect leads to control wiring. (See Fig. 9-13.) Use No. 18 AWG color-coded, insulated (35°C minimum) wire. If thermostat is located more than 10 ft from unit, as measured along the control voltage wires, use No. 16 AWG color-coded wire to avoid excessive voltage drop. All wiring must be NEC Class 1 and must be separated from incoming power leads. Use furnace transformer, fan coil transformer, or accessory transformer for control power, 24-v/40-va minimum. NOTE: Use of available 24-v accessories may exceed the minimum 40-va power requirement. Determine total transformer loading and increase the transformer capacity or split the load with an accessory transformer as required. IMPORTANT: Check factory wiring and wire connections to ensure terminations are secured properly. Check wire routing to ensure wires are not in contact with tubing, sheet metal, etc. Step 10—Compressor Crankcase Heater When equipped with a crankcase heater, furnish power to heater a minimum of 24 hr before starting unit. To furnish power to heater only, set thermostat to OFF and close electrical disconnect to outdoor unit. A crankcase heater is required if refrigerant tubing is longer than 50 ft. Step 11—Install Electrical Accessories Refer to the individual instructions packaged with kits or accessories when installing. Follow these steps to properly pumpdown a system and avoid negative suction pressure. 1. Fully back seat (open) liquid and vapor tube service valves. 2. Unit is shipped with valve stem(s) front seated (closed) and caps installed. Replace stem caps after system is opened to refrigerant flow. Replace caps finger-tight and tighten with wrench an additional 1/12 turn. Use a backup wrench on valve body flats to prevent distortion of sheet metal. 3. Close electrical disconnects to energize system. 4. Set room thermostat to desired temperature. Be sure set point is below indoor ambient temperature. 5. Set room thermostat to HEAT or COOL and fan control to ON or AUTO mode, as desired. Operate unit for 15 minutes. Check system refrigerant charge. SEQUENCE OF OPERATION NOTE: Defrost control board is equipped with 5-minute lockout timer which may be initiated upon any interruption of power. With power supplied to indoor and outdoor units, transformer is energized. Cooling On a call for cooling, thermostat makes circuits R-O, R-Y, and R-G. Circuit R-O energizes reversing valve, switching it to cooling position. Circuit R-Y energizes contactor, starting outdoor fan motor and compressor circuit. R-G energizes indoor unit blower relay, starting indoor blower motor on high speed. When thermostat is satisfied, its contacts open, de-energizing the contactor and blower relay. Compressor and motors should stop. NOTE: If indoor unit is equipped with a time-delay relay circuit, the blower runs an additional 90 sec to increase system efficiency. Heating On a call for heating, thermostat makes circuits R-Y and R-G. Circuit R-Y energizes contactor, starting outdoor fan motor and compressor. Circuit R-G energizes indoor blower relay, starting blower motor on high speed. Should temperature continue to fall, R-W2 is made through second-stage room thermostat bulb. Circuit R-W2 energizes a sequencer, bringing on first bank of supplemental electric heat and 5 CARRIER PROGRAMMABLE ONE CARRIER THERMOSTAT FA, FB, FC, FD, FF, FH HEAT OUTDOOR PROGRAMMABLE FA, FB, FC, MODEL HP FAN COILPUMP THERMOSTAT THERMOSTAT FD, FF, FH HEAT MODEL HP FAN COIL PUMP 24 VAC HOT R G W/W1 Y/Y2 O/W2 R W2 W3 E RVS COOLING C B S1 S2 W2 G...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien