Login:
Stimmen - 2, Durchschnittliche Bewertung: 3.5 ( )

Anleitung Central Pneumatic, modell 65903

Hersteller: Central Pneumatic
Dateigröße: 1.58 mb
Dateiname: 65903.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our website at: Read this material before using this product. Failure to do so can result in serious injury. Save this manual. Copyright© 2008 by Harbor Freight Tools®. All rights reserved. No portion of this manual or any artwork contained herein may be reproduced in any shape or form without the express written consent of Harbor Freight Tools. Diagrams within this manual may not be drawn proportionally. Due to continuing improvements, actual product may differ slightly from the product described herein. Tools required for assembly and service may not be included. For technical questions or replacement parts, please call 1-800-444-3353. Revised Manual 10g SKU 65903 For technical questions, please call 1-800-444-3353. Page 2 PRODUCT SPECIFICATIONS Motor 240 V~ / 60 Hz / 9 A (Load) / Single Phase / 4 HP Peak / 3 HP Working / 3,400 RPM / Two Capacitor (Run & Start) Overload Reset Button 15 A Power Cord 12 Gauge, 3-Wire (Stripped), 10 Ft. Long 240 Volt Power Cord Plug Not Included. Air Tank Capacity 29 Gallons SCFM Airflow 8.74 @ 40 PSI / 7.7 @ 70 PSI / 7.47 @ 90 PSI / 6.67 @ 115 PSI Compressor Pump Type Dual V-Head Cylinder / Belt Driven Safety Valve Setting 120 PSI Air Pressure Gauge Indicators 0-200 PSI in 5 PSI Increments Automatic Shut Off Capability Shut Off at 115 PSI / Starts at 80 PSI Required Air Quick Connector (Not Included) 1/4”-18 NPT Quick Connector V-Belt Size A1118 Li Base Mounting Holes Qty. 4 @ 1/2” Diameter UNPACKING When unpacking, check to make sure all the parts shown on the Parts List at the end of the manual are included. If any parts are missing or broken, please call Harbor Freight Tools at the number shown on the cover of this manual as soon as possible. SAVE THIS MANUAL You will need this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures, parts list and assembly diagram. Keep your invoice with this manual. Write the invoice number on the inside of the front cover. Keep this manual and invoice in a safe and dry place for future reference. GENERAL SAFETY RULES WARNING! READ AND UNDERSTAND ALL INSTRUCTIONS Failure to follow all instructions listed below may result in electric shock, fire, and/or serious injury. SAVE THESE INSTRUCTIONS WORK AREA Keep your work area clean and well lit.1. Cluttered benches and dark areas invite accidents. Do not operate compressors in explosive atmospheres, such as in the pres2. ence of flammable liquids, gases, or dust. Compressors create sparks which may ignite the dust or fumes. Keep bystanders, children, and visitors away while operating a compressor. 3. Provide barriers or shields as needed. ELECTRICAL SAFETY Grounded compressors must be plugged into an outlet properly installed 1. and grounded in accordance with all codes and ordinances. Never remove the grounding prong or modify the plug in any way. Do not use any adapter plugs. Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded. If the compressors should electrically malfunction or break down, grounding provides a low resistance path to carry electricity away from the user. Do not expose compressors to rain or wet conditions. 2. Water entering an electric motor will increase the risk of electric shock. Do not abuse the Power Cord.3. Never use the Power Cord to pull the Plug from an outlet. Keep the Power Cord away from heat, oil, sharp edges, or moving parts. Replace damaged Power Cords immediately. Damaged Power Cords increase the risk of electric shock. An extension cord must 4. never be used with this item. Connecting this item to an outlet through an extension cord may cause electrical damage to the motor and could present a fire hazard. PERSONAL SAFETY Stay alert. Watch what you are doing, and use common sense during use. 1. Do not use while tired or under the influence of drugs, alcohol, or medication. A moment of inattention while operating may result in serious personal injury. Dress properly. Do not wear loose clothing or jewelry. Contain long hair. 2. Keep your hair, clothing, and gloves away from moving parts. Loose clothes, jewelry, or long hair can be caught in moving parts. Avoid accidental starting.3. Be sure the Power Switch Lever is turned off before plugging in. Plugging in compressors with the Power Switch Lever on, invites accidents. Remove adjusting keys or wrenches before turning the compressor on. 4. A wrench or a key that is left attached to a rotating part of the compressor may result in personal injury. Do not overreach. Keep proper footing and balance at all times.5. Use safety equipment. Always wear eye protection. 6. Make sure you are wearing your protective clothing, safety glasses with side shields and dust mask or air respirator, if appropriate. TOOL USE AND CARE Do not force the compressor. Use the correct compressor for your applica1. tion. The correct compressor will ...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien