Login:
Stimmen - 2, Durchschnittliche Bewertung: 4 ( )

Anleitung Franklin, modell TB2CI

Hersteller: Franklin
Dateigröße: 1.52 mb
Dateiname:
Unterrichtssprache:enesfr
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Figure 9 Diffuser Motor Bracket Diffuser Bolt Diffuser Bolt Diaphragm Grommet 8 PARTS FOR TURF BOSS SELF-PRIMING SPRINKLER PUMP Figure Number Description Kit Grouping Identifi er* Repair Part Order Codes by Model Number TB1CI TB15CI TB2CI 1 Plug Kits A 305390901 2 Pump Case B 305491901 3 Grommet C 305392901 G 305396901 305396902 305396903 4 Diaphragm C 305392901 G 305396901 305396902 305396903 5 Fastener Kit* D 305393901 6 Diffuser E 305394901 305394902 305394903 G 305396901 305396902 305396903 7 Wear Ring E 305394901 305394902 305394903 G 305396901 305396902 305396903 8 Impeller E 305394901 305394902 305394903 G 305396901 305396902 305396903 9 Mechanical Seal F 305395901 G 305396901 305396902 305396903 10 Motor Bracket H 305397901 11 Motor I 305398901 305398902 305398903 12 Base Assembly J 305399901 * Items with like identifi ers are sold/packaged together ** Fastener kits (5D) is a complete set of the hardware used to assemble the Turf Boss. As a convenience all other repair kits contain the fasteners needed for the reassembly of its components. 11I 5D 5D 10H 9F,G 5D 5D 8E,G 7E,G 6E,G 5D 5D 4C,G 3C,G 1A 2B 5D 5D 1A 12J APPENDIX I APPENDIX II - TROUBLESHOOTING A. Pump does not deliver water or pressure E. Motor will not start Cause: The pump is not full of water. Cause: Open switches, blown fuses or loose connections. Remedy: Stop the pump, fill it with water, check all pipe connections to make sure there are no air leaks Remedy: Check switches, fuses, and connections. and try again. Cause: Improper connections to motor. Remedy: Make sure connections are tight. B. Low pressure Cause: The motor is not up to speed. F. Air logging (excessive air in pipe) Remedy: Check for proper voltage and tight wiring Cause: Air leaks in pipe connections. Remedy: Check connections. Cause: The impeller is partially plugged. Cause: Water drops below the end of the pipe. Remedy: Check impeller for rocks or debris. Refer Remedy: Pump is out-producing well. Tighten down to disassembly instruction for getting to impeller. control valve gradually until pump starts operatingCause: Air is leaking into suction line. properly. Remedy: Check suction line connections. G. Gravelly noises inside pump (cavitation) C. Low capacity Cause: Pump running over capacity Cause: Your water level is deeper than 25 feet. (NPSHR exceeds NPSHA) Remedy: Pump can’t pump below 25 feet. Call your Remedy: Call your Franklin Pump Systems dealer. Franklin Pump Systems dealer. Cause: Suction pipe is too small or length of pipe is Cause: You are using too long a pipe from the too long. water to the pump. Remedy: Use a larger diameter pipe. Remedy: You should use a larger diameter pipe. Cause: End of suction pipe is in mud or sand. Cause: You have a plugged impeller. Remedy: Raise end of suction pipe or clean Remedy: Check impeller. Refer to disassembly out well. instructions above. Cause: The pipe from the pump to the water is partially plugged. Remedy: Check pipe. D. Motor overheats Cause: Improper voltage or wiring connections. Remedy: Check to see if your voltage is the same as indicated on the motor name on dataplate. Be sure all wiring connections are tight. Cause: Improper ventilation for the motor. Remedy: Check to see if motor is clean and properly vented. APPENDIX III - PERFORMANCE CURVE 40 35 30 25 20 15 10 5 0 0 10 20 30 40 50 60 70 80 0 1 2 3 4 5 0 10 00 30 40 50 60 70 80 90 20 100 110 METERSPSIFEET 5 10 15 20 25 30 35 40 45 130 140 120 50 55 60 2 HP 1.5 HP 1 HP GPM LPS 3 M PH 2 4 6 8 1012141618 10 APPENDIX IV - FRICTION LOSS TABLES 1” 1.” Schedule 40 pipe 1.049 in. i.d. / Type L Copper tube 1.025 in. i.d. GPM Velocity Ft/S Friction Loss Ft Hd./100 of pipe Velocity Ft/S Ft Hd./ 100 Pipe Fric. Loss C=130 Steel C=100 PVC C=140 2.0 0.74 0.60 0.32 .078 0.41 4.0 0.86 3.0 1.11 1.26 0.68 1.17 0.87 6.0 1.29 4.0 1.49 2.14 1.15 1.56 1.48 8.0 1.72 5.0 1.86 3.24 1.75 1.95 2.23 10 2.15 6.0 2.23 4.54 2.45 2.34 3.13 12 2.57 8.0 2.97 7.73 4.16 3.11 5.35 14 2.00 10 3.71 11.7 6.31 3.89 8.08 16 3.43 12 4.46 16.4 8.85 4.67 11.3 18 3.86 14 5.20 21.8 11.8 5.45 15.0 20 4.29 16 5.94 27.9 15.1 6.22 19.2 25 5.36 18 6.68 34.7 18.7 7.00 23.9 30 6.43 20 7.43 42.1 22.8 7.78 29.0 40 8.58 25 9.29 63.6 34.6 9.74 43.9 50 10.7 30 11.1 89.2 48.1 11.7 61.4 60 12.9 40 14.9 152 82.0 15.5 105 80 17.2 0.56 0.30 1.02 0.52 1.20 0.65 1.53 1.12 2.04 1.10 2.04 1.92 3.08 1.67 2.55 2.90 4.31 2.33 3.06 4.04 5.73 3.10 3.57 5.35 7.34 3.96 4.08 6.85 9.13 4.93 4.59 8.52 11.1 6.00 5.10 10.4 16.8 9.06 6.38 15.7 23.5 12.7 7.65 22.1 40.0 21.6 10.2 37.6 60.4 32.6 12.8 56.7 84.7 45.6 15.3 79.5 144 77.9 20.4 136 1.5” 2” Schedule 40 pipe 1.380 in. i.d. / Type L Copper tube 1.265 in. i.d. GPM Velocity Ft/S Friction Loss Ft Hd./100 of pipe Velocity Ft /S Ft Hd./ 100 Pipe Fric. Loss C=130 Steel C=100 PVC C=140 6.0 0.95 0.57 0.31 1.08 0.49 10 0.96 8.0 1.26 0.96 0.52 1.44 0.82 15 1.44 10 1.58 1.45 0.79 1.80 1.24 20 1.91 12 1.89 2.04 1.10 2.16 1.73 25 2.39 15 2.36 2.95 1.59 2.70 2.62 30 2.87 20 3.15 5.24 2.83 3.60 ...

Dieses Handbuch ist für folgende Modelle:
Pumps - TB15CI (1.52 mb)
Pumps - TB1CI (1.52 mb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien