Login:
Stimmen - 4, Durchschnittliche Bewertung: 4.3 ( )

Anleitung DeWalt, modell A08184

Hersteller: DeWalt
Dateigröße: 2.85 mb
Dateiname: 2ffcc3a2-abb9-1e84-4119-0b06acf9b6b7.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Motor will stop when tank pressure reaches "cut-out" pressure. 2. Turn regulator knob clockwise to increase pressure and stop when desired pressure is reached. The compressor is ready for use. NOTE: Always operate the air compressor in well-ventilated areas free of gasoline or other combustible vapors. If the compressor is being used to operate a sprayer DO NOT place near the spray area. MAINTENANCE Customer Responsibilities Before each use Daily or after each use Frequently Yearly Check Safety Valve . Drain Tank . Air Filter .1 Air compressor pump intake and exhaust valves . 1- more frequent in dusty or humid conditions Unit cycles automatically when power is on. When performing maintenance, you may be exposed to voltage sources, compressed air, or moving parts. Personal injuries can occur. Before performing any maintenance or repair, disconnect power source from the compressor and bleed off all air pressure. A08184 14-ENG To ensure efficient operation and longer life of the air compressor outfit, a routine maintenance schedule should be prepared and followed. The following routine maintenance schedule is geared to an outfit in a normal working environment operating on a daily basis. If necessary, the schedule should be modified to suit the conditions under which your compressor is used. The modifications will depend upon the hours of operation and the working environment. Compressor outfits in an extremely dirty and/or hostile environment will require a greater frequency of all maintenance checks. NOTE: See "Operation" section for the location of controls. To Check Safety Valve If the safety valve does not work properly, over- pressurization may occur, causing air tank rupture or an explosion. 1. Before starting compressor, pull the ring on the safety valve to make sure that the safety valve operates freely. If the valve is stuck or does not operate smoothly, it must be replaced with the same type of valve. To Drain Tank 1. Set the On/Auto/Off lever to "OFF". 2. Turn the regulator knob counterclockwise to set the outlet pressure to zero. 3. Remove the air tool or accessory. 4. Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring. 5. Drain water from air tank by opening drain valve (counter-clockwise) on bottom of tank. Water will condense in the air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture. 6. After the water has been drained, close the drain valve (clockwise). The air compressor can now be stored. NOTE: If drain valve is plugged, release all air pressure. The valve can then be removed, cleaned, the reinstalled. Air Filter Inspection and Replacement Hot surfaces. Risk of burn. Compressor heads are exposed when filter cover is removed. Allow compressor to cool prior to servicing. Keep the air filter clean at all times. Do not operate the air compressor with the air filter removed. A dirty air filter will not allow the compressor pump to operate at full capacity. Before you use the compressor pump, check the air filter to be sure it is clean and in place. 15-ENG A08184 If it is dirty, replace it with a new filter. On some models,the filter may be removed by using a pair of needle nose pliers or a screwdriver. Pull or pry out the old filter and carefully clean the filter area. Push in the new air filter. Air Compressor Pump Intake and Exhaust Valves Once a year have a Trained Service Technician check the air compressor pump intake and exhaust valves. SERVICE AND ADJUSTMENTS Unit cycles automatically when power is on. When doing Maintenance, you may be exposed to voltage sources, compressed air or moving parts. Personal injuries can occur. Before performing any Maintenance or repair, unplug the compressor and bleed off all air pressure. ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE PERFORMED BY A TRAINED SERVICE TECHNICIAN. Before servicing: • Unplug or disconnect electrica supply to the air compressor. • Bleed tank of pressure. • Allow the air compressor to cool. To Replace or Clean Check Valve 1. Release all air pressure from air tank. See "To Drain Tank" in the Maintenance section. 2. Unplug outfit. 3. Using an adjustable wrench, loosen outlet tube nut at air tank and pump. Carefully move outlet tube away from check valve. 4. Using an adjustable wrench, loosen pressure relief tube nut at air tank and pressure switch. Carefully move pressure relief tube away from check valve. 5. Unscrew the check valve (turn counterclockwise) using a 7/8" open end wrench. Note the orientation for reassembly. Outlet TubeCheck ValveNutNutPressure Relief TubeIn closed position disc is visible. In open position nothing is visible. Screwdriver 6. Using a screwdriver, carefully push the valve disc up and down. NOTE: The valve disc should move freely up and down on a spring which holds the valve disc in the closed position; if not the check valve needs to be cleaned or replaced. 7. C...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien