Login:
Stimmen - 2, Durchschnittliche Bewertung: 5 ( )

Anleitung Hitachi, modell 210-208

Hersteller: Hitachi
Dateigröße: 176.99 kb
Dateiname: 308043F.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


INSTRUCTIONS Displacement Pump 1000 psi (70 bar, 7 MPa) Maximum Working Pressure Model 210–208, Series F 308–043 Rev. F Supersedes Rev. C and PCN D GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441 COPYRIGHT 1990, GRACO INC. Graco Inc. is registered to I.S. EN ISO 9001 Table of Contents Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Setup/Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 . ............................................................................. . Parts Drawing and Parts List. . . . . . . . . . . . . . . . . . . . 10 Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Graco Phone Numbers. . . . . . . . . . . . . . . . . . . . . . . . . 12 Symbols Warning Symbol WARNING This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions. Caution Symbol . This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions. . . EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury. . This equipment is for professional use only. . Read all instruction manuals, tags, and labels before operating the equipment. . Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor. . Do not alter or modify this equipment. Use only genuine Graco parts and accessories. . Check equipment daily. Repair or replace worn or damaged parts immediately. . Do not exceed the maximum working pressure stated on the equipment or in the Technical Data for your equipment. Do not exceed the maximum working pressure of the lowest rated component in your system. . Use fluids and solvents which are compatible with the equipment wetted parts. Refer to the Technical Data section of all equipment manuals. Read the fluid and solvent manufacturer’s warnings. . Handle hoses carefully. Do not use hoses to pull equipment. . Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose Graco hoses to temperatures above 66C (150F) or below –40C (–40F). . Wear hearing protection when operating this equipment. . Do not lift pressurized equipment. . Comply with all applicable local, state, and national fire, electrical, and safety regulations. . . . INJECTION HAZARD Spray from the gun, leaks or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury. . Fluid injected into the skin might look like just a cut, but it is a serious injury. Get immediate medical attention. . Do not point the gun/valve at anyone or at any part of the body. . Do not put your hand or fingers over the spray tip/nozzle. . Do not stop or deflect leaks with your hand, body, glove or rag. . Do not “blow back” fluid; this is not an air spray system. . Always have the tip guard and the trigger guard on the gun when spraying/dispensing. . Be sure the gun trigger safety operates before spraying. . Lock the gun trigger safety when you stop spraying/dispensing. . Follow the Pressure Relief Procedure on page 5 if the spray tip/nozzle clogs and before cleaning, checking or servicing the equipment. . Tighten all fluid connections before operating the equipment. . Check the hoses, tubes, and couplings daily. Replace worn or damaged parts immediately. Do not repair high pressure couplings; you must replace the entire hose. . Fluid hoses must have spring guards on both ends, to help protect them from rupture caused by kinks or bends near the couplings. . . . Moving parts can pinch or amputate your fingers. . Keep clear of all moving parts when starting or operating the pump. . Before checking or servicing the equipment, follow the Pressure Relief Procedure on page 5 to prevent the equipment from starting unexpectedly. . . . FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury. . Ground the equipment and the object being sprayed. Refer to Grounding on page 5. . If there is any static sparking or you feel an electric shock while using this equipment, stop spraying immediately. Do not use the equipment until you identify and correct the problem. . Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid being sprayed. . Keep the spray/dispense area free of debris, including solvent, rags, and gasoline. . Before operating this equipment, electrically disconnect all equipment in the spray/dispense area. . Before operating this equipment, extinguish all open flames or pilot lights in the spray/dispense area. . Do not smoke in the spray/dispense area. . Do not turn on or...

Dieses Handbuch ist für folgende Modelle:
Pumps - SERIES F (176.99 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien