Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.7 ( )

Anleitung KitchenAid, modell 4176199

Hersteller: KitchenAid
Dateigröße: 309.92 kb
Dateiname: 4552693b-f08d-4c84-922e-dbb4477329bb.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


A Pure Delivery Water Pump IMPORTANT: Read and save these instructions. IMPORTANT: Installer: Leave Installation Instructions with the homeowner. Homeowner: Keep Installation Instructions for future reference. Save Installation Instructions for local electrical inspector’s use. Before you start... Check location where water pump will be The water pump can be connected to the refrig- installed. Proper installation is your erator ice maker and water dispensing system. responsibility. Make sure you have everything Electrical Shock Hazard necessary for correct installation. It is the customer’s responsibility: The rating information is located on the base of To contact a qualified electrical installer. pump. To assure that the electrical installation l Personal Injury Hazard l Important: Observe all governing codes and is adequate and in conformance with l ordinances. Do Not use water pump to pump any National Electrical Code, ANSVNFPA 70- other liquids, use only for bottled water. Grounded electrical outlet is required. See latest edition**, and all local codes and l Electrical requirements. Clean system after extended periods of ordinances. non-use. Water connections to pump Do Not require Failure to do so could result in fire, sealing compounds to prevent leaking. Failure to follow these instructions may electrical shock or other personal injury. result in personal injury. L A separate water faucet can be connected to **Fire Protection Association the water pump. The water pump can be Batterymarch Park connected to any water faucet that can handle Quincy, Massachusetts 02269 40-60 PSI. A water faucet kit, Part No. 4319154 is available from your KitchenAid dealer or authorized parts distributor. Property/Product Damage l Do Not store water bottle and water pump in an area where temperatures fall below 32°F. Failure to follow these instructions may result in product or property damage. L Tools needed for installation: knife or 6 tubing cutter 12. Parts supplied for installation: \ outlet P Q bottle captubing \\ water bottle 4 tubing + \ \? \ l/4” outside / diameter 318” outside tubing diameter tubing ‘arts not supplied ‘or installation: -faucet kit Model -“T” fittings to route KWPFHXWO (Part tubing to multiple No. 4319154) locations (Part No. 4319152) If additional tubing is I required, you will need I tubing connector, Part switch No. 4319153 and 114” O.D. tubing, Part No. 4319151 If codes permit and a separate grounding Electrical requirements wire is used, it is recommended that a qualified electrician determine that the grounding path is adequate. A 120-volt, 60-HZ, AC-only, fused electrical supply is required. The total circuit ampere Electrical Shock Hazard load used including the water pump must not l Electrical ground is required on this Check with a qualified electrician if you exceed 90% of circuit-rated ampere capacity. l appliance. are in doubt as to whether the appliance The ampere rating of the water pump is l If cold water pipe is interrupted by is properly grounded. located on the base of the pump. l plastic, non-metallic gaskets or other This appliance is equipped with a power insulating materials, Do Not use for supply cord having a 3-prong grounding grounding. plug. To minimize possible shock hazard, 3-prong grounding-type . Do Not ground to a gas pipe. the cord must be plugged into a mating wall receptacle l 3-prong grounding-type wall receptacle, Do Not modify the power supply cord grounded in accordance with National plug. If it does not fit the outlet, have a Electrical Code, ANSVNFPA 70-latest 3-prong proper outlet installed by a qualified \ grounding edition and all local codes and ordin- electrician. antes. See Figure 1. If a mating wall Do Not have a fuse in the neutral or l receptacle is not available, it is the grounding circuit. A fuse in the neutral or personal responsibility and obligation of grounding circuit could result in the customer to have a properly electrical shock. grounded 3-prong wall receptacle ding . Do Not use an extension cord with this installed by a qualified electrician. appliance. Failure to follow these instructions could supply cord result in a serious injury or death. Figure 1 Panel A Now start... With pump in room where it will be installed. Determine where you wish to locate water pump and water bottle. The water bottle and water pump should be installed on the same level. The water bottle and water pump must be located close together since the tubing connecting the pump to the water bottle is 6 feet long. Use existing tubing between water pump and water bottle. Do Not cut this tubing or add tubing between pump and water bottle. Do Not remove clamp on end of tubing that connects inner tubing to outer tubing. Suggested locations: l Under the sink - especially for faucet connection. l Cabinet next to outlet connection. 21 21 Determine where you will need to run . water lines and the length of tubing that will be needed. If more tubing is needed than what i...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien