Login:
Stimmen - 2, Durchschnittliche Bewertung: 3 ( )

Anleitung HP, modell 020598

Hersteller: HP
Dateigröße: 412.29 kb
Dateiname: 24013e9b-59c6-4991-b24d-c6a400f5f1e7.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference. Self-Priming Engine-Driven Centrifugal Pumps Description These centrifugal pumps include a precision mechanical seal with stainless steel spring, EPDM seals, carbon face and ceramic seat, and a built-in check valve for better self-priming capabilities (up to 20 ft. suction lift). Clog resistant impeller is capable of handling solids up to 7/16" diameter. Pumps include molded carrying handle, rubber foot pads, and two 2" NPT pipe nipples. Handle liquids from 40. to 130. F (4. to 54. C). For use with nonflammable, non-abrasive liquids compatible with pump component materials. Applications include pumping clear, clean water, salt water, and some liquid fertilizers and herbicides. An optional Buna N Seal/O-ring/Flapper Kit (see Repair Parts List) is available for pumping additional liquids. If the liquid is not compatible with Buna-N (optional) or EPDM (standard) rubber materials, do not use these pumps. Specifications Suction inlet . . . . . . . . . . . . . . . . . . 2" † Discharge outlet. . . . . . . . . . . . . . . 2" † (†) Standard NPT (female) pipe thread. Dimensions (overall) 020598. . . . . . . . 13" H x 15" W x 18" L 020599 . . . . . . . . . 183.8L x 173.8W x 151.4H Engine 020598. . . . . . . . . . . . . . . . . 3.5 HP B&S 020599 . . . . . . . . 5.5 HP B&S OHV Intek Oil type . . . . . . . . . SAE 30W Detergent Weight 020598. . . . . . . . . . . . . . . . . . . . 38 lbs. 020599. . . . . . . . . . . . . . . . . . . . 43 lbs. Material . . . . Glass-filled polypropylene Safety Guidelines Failure to follow any warnings/ cautions can result in personal injury, pump damage, and/or property damage. This manual contains information that is very important to know and under stand. This information is provided for SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help recognize this information, observe the following symbols: Danger indicates an imminently hazardous situation which, if not avoided, WILL result in death or serious injury. Warning indicates a potentially hazardous situation which, if not avoided, COULD result in death or serious injury. Caution indicates a potentially hazardous situation which, if not avoided, MAY result in minor or moderate injury. NOTE: Indicates important information that, if not followed, may cause damage to equipment. Unpacking After unpacking the unit, inspect carefully for any damage that may have occurred during transit. Make sure to tighten fittings, bolts, etc., before putting unit into service. 3824-254-00 FW0520 0703 Supercedes NEW 7/2003 Operating Instructions and Parts Manual 020598 and 020599 020598 and 020599 Self-Priming Engine-Driven Centrifugal Pumps Unpacking (continued) Do not operate unit if damaged during shipping, handling or use. Damage may cause injury or property damage. General Safety Information 1. Know the pump application, limitations, and potential hazards. Read all manuals included with this product carefully. Be thoroughly familiar with the pump and the proper use of the equipment. Do not use to pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc. Do not use in flammable and/or explosive atmospheres. Pump should only be used with liquids compatible with pump component materials. Failure to follow this warning can result in death, serious personal injury and/or property damage. 2. Make certain that the power source (gas engine) conforms to the requirements of your equipment. 3. Provide adequate protection and guarding around moving parts. 4. Release all pressure within the system before servicing any component. 5. Drain all liquids from the system before servicing. 6. Secure the discharge line before starting the pump. An unsecured discharge line will whip, possibly causing personal injury and/or property damage. 7. Check hoses for weak or worn condition before each use, making certain that all connections are secure. 8. Periodically inspect pump and system components. Perform routine maintenance as required (See Maintenance section). 9. Provide a means of pressure relief for pumps whose discharge line can be shut-off or obstructed. 10. Personal Safety: a. Wear safety glasses at all times when working with pumps. b. Wear a face shield and proper apparel when pumping hazardous chemicals. c. Keep work area clean, uncluttered and properly lighted; replace all unused tools and equipment. d. Keep visitors at a safe distance from the work area. e. Make workshop child-proof – with padlocks, master switches, and by removing starter keys. 11. Carefully read instruction manuals supplied by engine manufacturer before attempting to assemble, operate, or service the engine or any part. The WARNING statements indicate potentially hazardous conditions for operator or equipment. TAKE NECESSARY STEPS TO PROTECT PERSONNEL AND EQUIPMENT. Gasoline is a hig...

Dieses Handbuch ist für folgende Modelle:
Pumps - 020599 (412.29 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien