Login:
Stimmen - 4, Durchschnittliche Bewertung: 3 ( )

Anleitung HP, modell Pressure Booster Pumps 0306

Hersteller: HP
Dateigröße: 467.7 kb
Dateiname: 3ee57179-00af-4632-b645-5f27ef94b938.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference. Supersedes 0306 Pressure Booster Pumps Description Pressure booster pumps increase water pressure from city mains or private water systems. Applications include providing high water pressure for washing buildings, dairy walls or floors, hog parlors, poultry houses, rinsing or spray cooling equipment, lawn sprinkling and insecticide spraying. Stainless steel models can handle salt-water and contaminated water in reverse osmosis filter and other aggressive water applications. Single-phase models are equipped with a capacitor start, thermal protected motor. Three-phase models require separate overload protection. H Inlet I Unpacking When unpacking the unit, inspect carefully for any damage that may have occurred during transit. NOTE: Use pump with clear water only. Discharge J G E F Figure 1 A C D B IL0391 60 Hz Motor Driven Pump Dimensions (See Figure 1) • Chart A Stainless Steel Fitted Powder-Coated Cast Iron Fitted Cast Iron Fitted Dimensions In Inches Lbs. Ship Wt.A B C D E F G H I J PB0508S031 PB0512S051 PB0516S071 PB0712S071 PB1014S101 PB1016S151 PB1914S201 PB2711S201 PB3506S201 PB2714S301 PB3508S301 - - - - PB0508C031 PB0512C051 PB0516C071 PB0712C071 PB1014C101 PB1016C151 PB1914C201 PB2711C201 PB3506C201 PB2714C301 PB3508C301 - - - - PB0508A031† PB0512A051† PB0516A071 PB0712A071 PB1014A101 PB1016A151 PB1914A201 PB2711A201 PB3506A201 PB2714A301 PB3508A301 PB5504A201 PB5506A301 PB8504A201 PB8505A301 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-3/4 3-3/4 3-3/4 3-3/4 3-3/4 3-3/4 3-3/4 3-3/4 3-3/4 3-3/4 3-3/4 3-3/4 3-3/4 3-3/4 3-3/4 10-3/16 13-3/8 16-1/2 13-3/8 16-5/16 17-5/8 18-1/8 15-3/8 13-15/16 18-1/2 17-1/8 13-3/4 18-1/16 16-1/2 19-5/16 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 6-1/2 6-1/2 6-1/2 6-1/2 6-1/2 6-1/2 6-1/2 6-1/2 6-1/2 6-1/2 6-1/2 6-1/2 6-1/2 6-1/2 6-1/2 19-15/16 23-3/8 27 23-7/8 27-1/4 29-3/16 29-11/16 27-1/2 25-7/8 30-9/16 29-3/16 25-15/16 30-3/16 28-5/8 31-1/2 7-3/8 7-3/8 7-3/8 7-3/8 7-3/8 7-3/8 7-3/8 7-3/8 7-3/8 7-3/8 7-3/8 7-3/8 7-3/8 7-3/8 7-3/8 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 2-1/8 2-1/8 2-1/8 2-1/8 3/4 3/4 3/4 3/4 3/4 3/4 3/4 1 1 1 1 2 2 2 2 3/4 3/4 3/4 3/4 3/4 3/4 3/4 1 1 1 1 2 2 2 2 35 38 43 42 48 51 51 52 51 54 53 57 57 58 58 50 Hz Motor Driven Pump Dimensions (See Figure 1) •58 PB0508Y031 PB0514Y051 PB0714Y071 PB1020Y101 PB1023Y101 PB2717Y201 - PB1021Y101 PB1920Y151 - - - - - PB1023Z101 - - - - PB1922Z201 PB0508X031 PB0514X051 PB0714X071 PB1020X101 PB1023X101 - PB3508X151 - - - 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-1/4 3-3/4 3-3/4 3-3/4 3-3/4 3-3/4 3-3/4 3-3/4 3-3/4 3-3/4 3-3/4 10-3/16 14-7/16 14-15/16 21-11/16 24-3/8 21-5/16 16-13/16 22-1/2 24-1/16 26-1/8 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 3-7/8 6-1/2 6-1/2 6-1/2 6-1/2 6-1/2 6-1/2 6-1/2 6-1/2 6-1/2 6-1/2 20-3/16 25-7/16 25-15/16 33-5/16 36 33-7/16 29-11/16 34-3/16 34-3/8 37-3/16 7-3/8 7-3/8 7-3/8 7-3/8 7-3/8 7-3/8 7-3/8 7-3/8 7-3/8 7-3/8 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 1-7/16 3/4 3/4 3/4 3/4 3/4 1 1 3/4 3/4 3/4 3/4 3/4 3/4 3/4 3/4 1 1 3/4 3/4 3/4 34 41 47 53 55 56 52 54 56 59 (*) NOTE: Figure 1, holes in mounting base are open slotted 3/8” wide x 1/2” long; dimension A & B are centerline from these open slotted holes. These holes are suitable for 1/4 to 3/8” bolts. Dimensions also apply to three phase models. (†) Equipped with carrying handle. 132079 handle available as an option on other models. Add 1-3/8” to “G” if handle is included. 1 FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 • 132934 PERFORMANCE SPECIFICATIONS PRESSURE ADDED - PSI 10 20 40 60 80 100 120 140 160 180 200 Max. Press. PSI Suction Pipe Tap NPT Disch. Pipe Tap NPT Stainless Steel Fitted Powder- Coated Cast Iron Fitted Cast Iron Fitted HP Stage Output - Gallons per Minute PB0508C031 PB0508A031• 1/3 8 9.5 8.7 7.3 5.8 3.5 87 3/4” 3/4” PB0512S051 PB0512C051 PB0512A051• 1/2 12 9.8 9.2 8.2 7.3 6.3 5.2 3.5 131 PB0516S071 PB0516C071 PB0516A071 3/4 16 9.9 9.5 8.7 8.0 7.3 6.5 5.8 4.8 3.5 175 PB0712S071 PB0712C071 PB0712A071• 3/4 12 14.0 13.4 12.2 10.9 9.5 7.9 6.0 3.6 152 PB1014S101 PB1014C101 PB1014A101 1 14 * * 14.5 13.4 12.3 11.2 9.8 8.3 6.3 3.3 185 PB1016S151 PB1016C151 PB1016A151 1-1/2 16 * * 14.7 13.8 12.9 11.9 10.8 9.7 8.2 6.6 4.3 211 PB1914S201 PB1914C201 PB1914A201 2 14 27.5 27.0 25.7 24.2 22.6 20.8 18.7 16.2 13.0 7.8 190 PB3506S201 PB3506C201 PB3506A201 2 6 41.5 41.1 40.5 34.2 23.3 90 1” 1” PB2711S201 PB2711C201 PB2711A201 2 11 * * 31.3 29.3 26.8 23.8 19.8 13.0 150 PB3508S301 PB3508C301 PB3508A301 3 8 41.5 41.1 40.9 40.0 34.2 26.4 10.0 120 PB2714S301 PB2714C301 PB2714A301 3 14 * * 32.2 30.6 28.9 27.0 24.8 22.0 18.4 12...

Dieses Handbuch ist für folgende Modelle:
Pumps - Pressure Booster Pumps 0907 (467.7 kb)
Pumps - Pressure Booster Pumps FW0154 (467.7 kb)
Pumps - Pressure Booster Pumps IL0391 (467.7 kb)

Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien