Login:
Stimmen - 4, Durchschnittliche Bewertung: 4.5 ( )

Anleitung Yamaha, modell PW2000M

Hersteller: Yamaha
Dateigröße: 197.77 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Dieses Gerät hat auch andere Anweisungen:

Anleitung Zusammenfassung


Since it is specifically designed for use with these mixers, do not attempt to use it to supply power to any other equipment, or use any other power supply with your M2000 mixer. There are three models of the PW2000M power supply — a 100VAC model for use in Japan, a 120VAC model for use in the USA and Canada, and a 230VAC model for use elsewhere in the world. ENSURE YOU ARE USING THE CORRECT MODEL FOR YOUR LOCAL POWER SUPPLY BEFORE CONNECTING THE POWER! Front panel Rear panel Front and rear panel © Power switch (POWER) When this switch is depressed, AC power is supplied to the PW2000M, and the correct DC voltages are supplied to the M2000 console via the umbilical cable. The LED next to the switch indicates when the power is on. (2) Operating monitor (OPERATION MONITOR) There are 4 green LED indicators to monitor the power supplied to the M2000 mixing console (+48, +12, +17, and -17V). In normal operation, these LEDs should all be lit. If one or all are off, it means that there is a fault in the power being supplied to your M2000. Contact your Yamaha service center if this happens. (3) Umbilical connector (DC OUTPUT) This locking multi-pin female connector supplies regulated power to the M2000 from the PW2000M. To lock the connector into place, push and turn clockwise. Reverse to unlock and remove the connector. CAUTION: Always make sure that the power to the PW2000M is turned off before connecting or disconnecting this connector to or from either the console or the PW2000M. PW2000M umbilical connector pin assignments ® Main Fuse (FUSE) This is the primary fuse of the PW2000M power supply. If it is blown replace it only with a fuse of the same current rating and type (6A 250V slow-blow for Japanese, USA and Canadian model, T3.15A 250V slow-blow for the 230V General model). © Power cable Used to connect the PW2000M to the AC mains. Pin Function 1 E (+48V) 2 E(+12V) 3 E (±17V) 4 +48V 5 +12V 6 + 17V 7 -17V 8 GND 9 DETECT A 10 DETECT B 2 General specifications Dimensions (w x d x h) 480 x 334.5 x 98 mm (18-7/8" x 13-3/16" x 3-1/2 ") Weight 13kg (28.5 lb) Secondary ±17V 2.5A +12V 3.8A +48V 0.3A Power requirements USA and Canadian models: British model: General model: Mounting 120VAC, 60Hz 240V, 50Hz 230VAC, 50Hz Shelf mounting The PW2000M can be used on any flat level surface as long as there is adequate ventilation. Do not remove the feet as this will block airflow through the bottom panel. PW2000M Air Flow * S" — MiPW|»oaM — o Ç&-5. © I 1 """..................CZJ...... Air Flow 4 - Permanent-installation racks The PW2000M can be mounted in any standard 19" electronic equipment rack. The rear panel of the rack should be left open to promote smooth airflow. Refer to the illustration below for ideal cooling configuration. PW 2000M : III'.....:.................................... llllillllijlllllll o o I-ft Ml '1<1


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien