Login:
Stimmen - 3, Durchschnittliche Bewertung: 3.7 ( )

Anleitung Roland, modell EP-7

Hersteller: Roland
Dateigröße: 551.71 kb
Dateiname:
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


Among Roland products the MT-32 is probably the most well known. (*2) A sequencer is a device which is capable of recording and piaying back MIDI messages, The PR-100 Recorder is a representative example of a Roland sequencer. There is a!so the MT-100, which combines a sequencer and sound module in the same unit. шшак onnections TUNE Mim.. ш ППРИТ................ Я I (MONO) DC IN 12V __ 1700mA [~ From this connector MIDI messages are transmitted. If you wish to use the ep-7 to play the sounds of another MIDI compatible unit, such as a sound module; or want to send the information describing what you play to a sequencer for recording, connect a cable so it runs from here to the MIDI IN connector on the external device. This connector is where MID! messages are received, if you wish to have the ep-7 be piayed as a result of messages sent by a MIDI sequencer or other external unit connect a cable so it runs from here to the MIDI OUT connector on the external device. In order to make the connections between the connectors on two units, you will need to have at least one MIDI Cable. (MSC-15/25/50, sold separately.) <3D (Example Setups) Connecting a sound module, such as the MT-32 Connecting a sequencer ep.7 ep.7 • Connecting the MT-100 ep.7 — MIDI — МТ-Ш0 OUT in 9 9 MIDI THgupÏÏTfN In a setup where the ep-7 is combined with a sequencer, the sequencer would usually be set at "Soft Thru ON." In this case, as explained below, the ep-7 should be set at “Local OFF." With the cable connections between the ep-7 and the sequencer made as illustrated below, what you play can be recorded into the sequencer; and the sequencer can be played back to hear a reproduction of of what you piayed. PIANO E. PIANO VIBRAPHONE ORGAN STRINGS Sequencer MiDI [N MIDI OCJT MIDI OUT MIDI IN Memory Take for example that “Soft Thru" on the sequencer is “ON”, and Local is left at “ON” on the ep-7 — each note played will then sound twice. This may cause the music to sound somewhat strange, and can result in some notes being omitted. Sequencer ( Sound Source ^ Local On(D Key pressed once, yet note sounds twice. MIDI IN MIDI OUT MIDI OUT MIDI ÍN Memory T Soft Thru On© The reason the above occurs is because the keyboard’s performance information reaches the sound source by means of two paths: © The ep-7’s internal circuitry. (D The "Soft Thru" feature on the sequencer, which when ON, wends from MiDI OUT a copy of everything received. Since this situation is undesirable, path 0 can be disabled. To do this the unit is set to "Local OFF”. The ordinary condition — where path © remains operative — is referred to as “Local ON". ON: Local On OFF: Local Off On Off *Each time power is turned on this setting will always be at "ON.' Omni On/Off When set to "Omni On", MIDI messages received on any of the channels will resuit in sound being produced. With the ep-7 set to Omni On, when data is received from a sequencer or other device you will be able to hear ail the performance data for ali the channels played at the same time. This makes it convenient for times when you wish to check how a compiete arrangement sounds. PIANO 5. PIANO VSR APHONE ORGAN STRINGS LOCAL ON Ordinary condition the keyboard and the internal sound module are connected. Sound is produced » t ( SQund~Module^j Local On LOCAL OFF Since there is no longer a connection between the keyboard and the internal sound module, when the keyboard is piayed no sound is produced. No sound is produced f Sound_Module ) mill II! 1!. *Each time power is turned on, the instrument will be at "Off." * This setting switches to Omni Off whenever selection of a particular Receive channel is made. lurning I ransmission/ Reception of Program Changes On and Off Tin ii»] Channel MIDI communication takes place on separate channels {MIDI Channels), numbered from 1 through 16. The channel used by the transmitting unit must be matched with that used by the receiving unit Only then will sound be produced as expected. • In a setup where you wish to play the ep-7 and also have another MIDI-equipped instrument or sound module play the same notes, you first should set the channel used for reception on your external device to the same channel that you have the ep-7 set to use for transmission. • If using another MIDI keyboard as a master instrument, and you wish to have the ep-7 played by it, you would need to set the channel used for reception on the ep-7 to the same channel that the master keyboard will be transmitting on. • When wishing to have a sequencer play the ep-7, you need to set the channel used for reception on the ep-7 to the same channel that the recorded MIDI data is set to use. Setting the Channel Used for Transmission PIANO £. PIANO VIBRAPHONE ORGAN STRINGS Ô Setting the Channel Used for Reception PIANO E. PIANO VIBRAPHONE ORGAN STRINGS Program Change messages basically state something to this effect "A change has been made ...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien