Login:
Stimmen - 1, Durchschnittliche Bewertung: 3 ( )

Anleitung Omega, modell RD260A

Hersteller: Omega
Dateigröße: 1.72 mb
Dateiname: M3289.pdf
Unterrichtssprache:en
Link zum kostenlosen Download Hinweise finden Sie am Ende der Seite



Anleitung Zusammenfassung


c o m OMEGAne t® On-Line Service Internet e-mail h t t p : / / w w w.omega.com i n f o @ o m e g a . c o m Servicing North America: USA: One Omega Drive, Box 4047 ISO 9001 Certified Stamford, CT 06907-0047 Tel: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.com Canada: 976 Bergar Laval (Quebec) H7L 5A1 Tel: (514) 856-6928 FAX: (514) 856-6886 e-mail: info@omega.ca For immediate technical or application assistance: USA and Canada: Sales Service: 1-800-826-6342 / 1-800-TC-OMEGASM Customer Service: 1-800-622-2378 / 1-800-622-BESTSM Engineering Service: 1-800-872-9436 / 1-800-USA-WHENSM TELEX: 996404 EASYLINK: 62968934 CABLE: OMEGA Mexico and Latin America: Tel: (001) 800-826-6342 FAX: (001) 203-359-7807 En Espan.ol: (001) 203-359-7803 e-mail: espanol@omega.com Servicing Europe: Benelux: Postbus 8034, 1180 LAAmstelveen, The Netherlands Tel: (31) 20 6418405 FAX: (31) 20 6434643 Toll Free in Benelux: 0800 0993344 e-mail: nl@omega.com Czech Republic: ul. Rude armady 1868, 733 01 Karvina-Hranice Tel: 420 (69) 6311 8 9 9 FAX: 420 (69) 631111 4 Toll Free: 0800-1-66342 e-mail: czech@omega.com France: 9, rue Denis Papin, 78190 Trappes Tel: (33) 130-621-400 FAX: (33) 130-699-120 Toll Free in France: 0800-4-06342 e-mail: france@omega.com Germany/Austria: Daimlerstrasse 26, D-75392 Deckenpfronn, Germany Tel: 49 (07056) 3017 FAX: 49 (07056) 8540 Toll Free in Germany: 0130 11 21 66 e-mail: info@omega.de United Kingdom: One Omega Drive, River Bend Technology Centre ISO 9002 Cert i f i e d Northbank, Irlam, Manchester M44 5EX, United Kingdom Tel: +44 (0) 161 777-6611 FAX: +44 (0) 161 777-6622 Toll Free in United Kingdom: 0800-488-488 e-mail: info@omega.co.uk It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that a p p l y. OMEGA is constantly pursuing certification of its products to the European New Appro a c h D i rectives. OMEGA will add the CE mark to every appropriate device upon cert i f i c a t i o n . The information contained in this document is believed to be correct, but OMEGA Engineering, Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications without notice. WARNING: These products are not designed for use in, and should not be used for, patient-connected applications. INTRODUCTION Thank you for purchasing the OMEGA industrial strip-chart recorder. The RD260A recorder comforms to the EMC standard as follows. EM1 EN55011: class A EMS EN50082-2 To take full advantage of numerous capabilities and to operate this instrument correctly and efficiently, please read this Instruction Manual before use. This manual describes both Pen and Dot-printing models of the SR1000 recorder. NOTE • The contents of this manual is the subject to change without notice. • All reasonable effort has been made to ensure the accuracy of the contents of this manual. However, if you find any ambiguous descriptions, please inform OMEGA. • All rights reserved. No part of this manual may be reproduced or transmitted in any form. SAFETY PRECAUTIONS WARNING CAUTION This recorder is developed to satisfy and to be used under the following conditions: • The recorder is a component type instrument to be installed on an instrumentation panel or rack. • The recorder complies with EN61010-1. • The recorder conforms to EN55011 (EMI) Group 1, Class A (for commercial and industrial use). • This instrument complies with Installation (over-voltage) Category II. The following safety precautions must be observed during all phases of operation, maintenance, and repair of the recorder. If this instrument is used in a manner not specified in this manual, the protection provided by this instrument may be impaired. Also OMEGA assumes no liability for the customer’s failure to comply with these requirement. General definitions of safety symbols used on the recorder and in this manual. Monitory symbol; the elements marked with this symbol alert the user to refer to the instruction manual to avoid personal injury or recorder damage. Protective grounding terminal; this terminal must be connected to the ground before turning the power switch on. High temperature; to avoid injury caused by hot surface, don’t touch the heats in. Alternative current; This manual uses the following signs for safety precautions: A WARNING sign denotes a hazard. It calls attention to a procedure, practice, condition or the like, which, if not correctly performed or adhered to, could result in personal injury or death of personnel. A CAUTION sign denotes a hazard. It calls attention to a procedure, practice, condition or the like, which, if not correctly performed or adhered to, could result in damage to or destruction of part or all of the recorder. Power Supply Ensure the source voltage matches the specified power supply voltage before turning on the power. WARNING WARNING Protective Grounding Make sure to connect the protective grounding to prevent an electric shock before turning on the power. Necessity of...


Bewertungen



Bewerten
Vorname:
Geben Sie zwei Ziffern:
capcha





Kategorien